| M Series Digital / Analog Mass Flow Meters |
| Manufacturer: Alicat Scientific |
| |
|
Digital or analog mass flow meters, regardless of manufacturer, serve a single purpose...to measure the flow of gases through a system. Mass flow meters must be accurate, versatile, dependable and cost effective.
The Alicat Scientific's M series digital / analog mass flow meter was designed to meet and exceed the requirements that customers place on mass flow meters:
Simplicity
Alicat M series mass flow meters were designed to be used as a stand-alone device. With the native display, a user can easily change the configuration of the meter without the need for computers, complicated software or scripts.
Accuracy
Alicat M series mass flow meters can be configured with an accuracy spec of up to +/-(0.4% of reading + 0.2% of full scale) with a high-accuracy calibration. Standard calibrations are rated at +/-(0.8% of reading + 0.2% of full scale)
Reduced Cost of Ownership
Alicat M series and V series flow meters require very little power to run thereby reducing operating costs. M and V series flow instruments also have less pressure drop when compared to similar flow devices. Reduced pressure drop means more process fluids go into your process and not into your measurement devices. The M series mass flow meters also measure pressure, temperature and volumetric flow in addition to mass flow which means fewer instruments you will have to buy and install. Adding a totalizer allows users to see how much media has flowed through the system, making it a great way to monitor usage and identify waste.
Versatility
M series mass flow meters are available in any flow range from 0.5SCCM through 1500SLPM. They are equipped with multiple analog outputs in addition to the RS-232 digital output. The M series meter can also be equipped with an Alicat 9V battery pack to make a stand alone secondary calibration standard or flow verification meter.
Speed
With a response time of under 10 milliseconds, Alicat mass flow meters respond more than twice as fast as your eye can blink.
Small Size
The M series mass flow meter has a footprint of 2.37'X1.050' through 4.00'X1.60' making it easy to integrate into systems or to use as a stand-alone calibrator.
Repeatability
Alicat's patented technology allows its mass flow meters to have very few moving parts. All of the internal components are fixed in place resulting in very little physical change inside the mass flow meter. Little physical change in the flow cavity means higher rates of consistency and repeatability. Alicat M series mass flow meters have a repeatability of +/-0.2% of FS
Dependability
There are currently over 22,000 Alicat products in service around the world. Alicat mass flow meters are being used in processes like leak detection, flow monitoring and atmospheric testing.
All Alicat Scientific mass flow meter calibrations are NIST traceable.
|
|
|
|
|
|
| |
| Features and Benefits of Alicat M series mass flow meters |
|
|
|
|
Measured Parameters
Mass Flow
Volumetric Flow
Pressure (PSIA)
Temperature (ฐ Celsius)
Display
All measured parameters are displayed in real time on the digital display. Any measured parameter can be brought to the center of the screen. Remote displays are also available.
Versatility
Multiple process measurements in one device to reduce the need for other measurement devices.
Response speed can be adjusted by the user to suit the application
Multiple analog & digital outputs to make communicating with the device easier and less costly.
100:1 Turndown ratio allows the flow meter to measure flow at 1/100th of its full scale rating
30-Gas Select on all units reduces inventory requirements
The max flow rate for the mass flow meter does not change, regardless of gas!
"Tare" feature allows the user to zero the unit at any time
Customizable units of measure for added ease of use
Optional Remote Display allows for panel mount of the display with full push-button control in embedded applications
30 factory installed, user selectable, gas calibrations:
Air
Argon
Methane
Carbon Monoxide
Carbon Dioxide
Ethane
Hydrogen
Helium
Nitrogen
Nitrous Oxide
Neon
Oxygen
Propane
Butane
Acetylene
Ethylene
Iso-Butane
Krypton
Xenon
Sulfur Hexaflouride
75% Argon + 25% C02
90% Argon + 10% C02
92% Argon + 8% C02
98% Argon + 2% C02
75% Argon + 25% Helium
75% Helium + 25% Argon
75% CO2 + 25% Argon
Helistarฎ A1025
Stargonฎ CS
95% Argon + 5% CH4
Communication
RS-232 output of all measured parameters
RS-485 available
PROFIBUS compatible communication standard
Choice of analog output of main parameter
0-5Vdc, 1-5Vdc, 0-10Vdc, or 4-20mA
Local Display
Customization
Alternate STPs for mass units
Lower pressure drops cut material costs.
0-10Vdc or 4-20mA outputs; 2 channels
Totalization
Gas blend calibrations
Alternate units of measure (SCFM, SCFH, etc)
Battery pack for portable operation
Locking 6-pin electrical connection
DB-15 connection
No display units for OEMs
Bi-directional flow capability
Class 1 Div 2 version available.
ATEX approved version available.
|
|
|
|
|
|
 |
|