Time Domain Reflectometry (TDR) (DR7100 Series)
Manufacturer: Drexelbrook
 
Guided Radar (TDR) Continuous Level Transmitter

Overview

The new DR7100 with its more advanced design solutions  has higher signal dynamics. Sharper Pulses measure thinner interfaces. The superior Time Base Stability allows better reproductibility, which translates to better reliability.

  • Easy Navigation & Viewing
    Choice of different Touch Screens: (tank illustration, bargraph, oscilliscope...)
  • 2-Wire
    Class I Div1, Zone 0 Installation
  • Special Process Separator for Extreme Conditions
  • Probe Types and Materials for all Applications

Most Stable Measurement
Despite disturbances such as strongly agitated surfaces, foam and coating of the probe or fine dust in the tank, DR7100 will continue to measure where competitors’ devices fail.

Measures any Product ...
Most 2-wire TDR devices measure down to a dielectric of 1.5. As a result, many organic compounds are not measured properly. DR7100 measures down to 1.4 (and even 1.1 using superior tank-bottom following mode).

... in any Application
5 different probes means there’s not an application that we can’t handle.

Makes Level Gauging Easier than Ever
Wizard Works Wonders
Setting up a 2-wire level gauge couldn’t be easier:
Simply fit the gauge to the tank, wire it up and switch it on:

  • Step 1 – The DR7100 tests itself to make sure its electronics are working perfectly.
  • Step 2 – The DR7100s Wizard walks you through a simple series of questions to define your tank and the product you want to measure.
  • Step 3 – That’s all you need. Your DR7100 is already measuring.

Interactive Help
Not certain what to do?  You don’t need a handbook. Simply wait 10 seconds, the help screen will appear and tell you what to do.

Specifications

Input
Function  Time Domain Reflectometry (TDR)
Parameter  Level, distance, volume and / or interface
Max. measuring range Double rod 8mm / 0.3” 4m / 13ft
 Single rod 8mm / 0.3” 4m / 13ft
 Coaxial 22mm / 0.9” 6m / 20ft
 Double cable 4mm / 0.15” 35m / 115ft
 Single cable 4mm / 0.15” 35m / 115ft
 Single cable 8mm / 0.3” 35m / 115ft

Output Signal
Output signal 1 4 - 20mA HART® or 3.8 - 20.5 mA  acc. to NAMUR NE 43
Output signal 2 4 - 20mA or 3.8 - 20.5 mA (Optional)  acc. to NAMUR NE 43

Accuracy  0.05% (rel. 20 mA; 20°C / 68°F)
Resolution  ±2 µA
Temperature Drift  Typically 50 ppm/K
Error Signal  High: 22 mA; Low: 3.6 mA  acc. to NAMUR NE 43
Max. Load  350 ohm

Measuring Accuracy - Reference conditions acc. to IEC770
Temperature  +20°C ±5°C / +68°F ±9°F
Pressure  1013 mbar abs. ±20 mbar 14.69 psig ±0.29 psig
Relative Humidity  60% ±15%
Resolution  1 mm / 0.04 “
Accuracy  In Direct Mode
    Liquids ±3 mm / ±0.12”
 when L < 10 m / 33 ft;  ±0.03% of measured distance,  when L > 10 m / 33 ft
    Powders ±20 mm / ±0.8”
    Interface ±10 mm (r Constant)

Application Conditions
Ambient Temp.  -40…+80°C / -40…+175°F;  EEx i: -40…+60°C / -40…+140°F
Storage Temp.  -40…+85°C / -40…+185°F
Flange Temp.  -40…+150°C / -40…+300°F  (Ex: refer to relevant device spec.)
Shock Resistance  100°C/min

Process Conditions
Operating Pressure 1…40 bar / -14.5…580 psig;  subject to process connection and temp.
Dielectric Constant >_ 1.4 Coaxial Probes   >_ 1.6  For single and Twin Probes
Vibration Resistance IEC 68-2-6 and prEN 50178
 (10...57Hz: 0.075 mm / 57...150 Hz: 1 g)
Protection Category IP 66/67 equiv. to NEMA 6-6X

Mechanical Data
Housing  Aluminium
Wetted Parts
    Rod  Stainless steel (1.4404 / 316L);
 Hastelloy C-22 (2.4602)
    Coaxial Stainless steel (1.4404 / 316L);
 Hastelloy C-22 (2.4602)
    Cable (4mm /0.15") Stainless steel (1.4401 / 316);
 Hastelloy C-22 (2.4602)
Process Fitting  Stainless steel (1.4404 / 316L);
 Hastelloy C-22 (2.4602)
Gaskets  Viton (-40…+150°C / -40…+300°F);  Kalrez 6375 (-20…+150°C / -5 …+300°F)
Process Connection
Thread  G 3/4"...1 1/2"; NPT 3/4"...1 1/2"
Flange  DN 25…DN 150 (PN 40 / PN 16);  1”…8” (150 lb / 300 lb);  10 K (40…100A)

Electrical Connection - 2-Wire Power Supply
Terminals Output 1  Non-Ex/ EEx i 24 VDC (14 … 30 VDC)
 EEx d 24 V DC (20 … 36 VDC)
Terminals Output 2  Non-Ex/ EEx i / EEx d  24 VDC (10 … 30 VDC)
Cable Entry Terminals  M20x1.5; 1/2 NPT; G 1/2"
 0.5…1.5 mm²

Time Domain Reflectometry (TDR)
 
 Resources
PDF File – Requires Adobe Reader Data Sheet
PDF File – Requires Adobe Reader Product Manual
ZIP File PACTware Software