Milliamp Process Clamp Meter (Model 771)
Manufacturer: Fluke
 
Price: $545.00 (USD)
Stock Status: 2 to 3 weeks

Don¡¯t break the loop on 4-20 mA signal measurements and save time.

Are you spending time?

  • Taking mA measurements by removing a wire and breaking the loop
  • Calling the control room to isolate a loop
  • Testing analog input/output on a console
  • Troubleshooting devices with mA inputs and outputs
  • Repairing intermittent or erratic 4-20 mA loops
  • Going back to the shop to get extra tools

If you need more time in your busy day check out the Fluke 77X mA Clamp Meters. They are designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

Here are some specific ways the 77X Clamp Meters will help you:

Milliamp Clamp Features Application How it saves time and money
Measure mA signals for PLC and control system analog I/O without breaking the loop. (771, 772 and 773) Measures low level dc current Correlate process indication with real physical value
Measure output signals from transmitters without breaking the loop (771, 772 and 773) Maintain and troubleshoot process and automation equipment without breaking the loop No disruption to the process
Detachable clamp with extension cable (771, 772 and 773) Measurements in tight locations Enables measurements in difficult situations
Source, simulate and measure mA signals in circuit (break the loop) (772 and 773) Confirm non-contact measurement. Have the next tool in hand for troubleshooting (source simulate) Eliminates the need to return to the shop to get a loop calibrator for troubleshooting after finding a bad signal with non-contact measurement
Source and measure VDC (773 only) Troubleshoot voltage input and output devices. Measure presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signals. Test chart recorders
4 to 20 mA In/out (773 only) Dual channel mA source and measurement for troubleshooting Source 4 to 20 mA signals into valves and mA signal conditioners and simultaneously measure 4 to 20 mA positioning output signals.
4 to 20 mA scaled output (773 only) Scaled mA output provides a mA signal output representative of the measured mA value Connect a logging DMM and log the mA signal without breaking the loop
Loop power supply (772 and 773) Power a transmitter Substitute testing of the installed 24V loop power supply. Power a transmitter and measure its mA output signal for troubleshooting.
Dual backlit display with both mA measurement and percent of 4 to 20 mA span (771, 772 and 773) Clear measurement presentation Allows quick measurement evaluation
Measurement Spotlight (771, 772 and 773) Illuminates hard to see wires in dark enclosures Measurement process is easier and quicker
Measure up to 99.9 mA range non-contact (771, 772 and 773) Wide range of measurements Measures 10 to 50 mA signals in older control systems
Automatic power off (771, 772 and 773) After 15 minutes and 2 minute automatic off for backlight and spotlight Saves battery life

Milliamp Process Clamp Meter
 

 Features

The 772 and 773 expand upon the capabilities of the popular 771 mA Clamp Meter. Now all you have to do is decide which model will help you save the most time. The Fluke 771, 772 and 773 features:

  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ¡±breaking the loop¡±
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

772 and 773 add:

  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing

773 Only Features:

  • DC voltage measurement to verify 24V power supplies or voltage I/O signals
  • Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
  • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
    • Enables milliamp signal logging to a separate logging device without breaking the loop
    • Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
  • mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
    • Apply a mA input signal to a device and measure its¡¯ 4-20 mA output on devices such as valves or mA isolators
  • Voltage output linear ramp or 25% step output
    • Automatically change the voltage output for remote testing

Here is an overview of the different models and their features:

What¡¯s the difference between the 77X models?

  Fluke-771 Fluke-772 Fluke-773
  Non-contact mA loop measurement Integrated mA loop troubleshooting Advanced process troubleshooting
mA measure, jaw X X X
mA measure, in circuit   X X
Loop power   X X
mA source   X X
DCV measure     X
DCV source     X
mA scaled output     X
mA in / out     X

 

Environmental Specifications
Diameter of measurable conductor
0.177¡± or 4.5 mm max
Operating temperature
-10 to 50 ¨¬C
Storage Temperature
-25 to 60¨¬C
Operating Humidity
< 90% @ <30 ¨¬C, < 75% @ 30 to 55¨¬C
Operating Altitude
0 to 2000 m
IP Rating
IP 40
Size
771: 59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.)
772, 773: 44 x 70 x 246 mm (2 7/8 x 5 ¨ú x 11 5/8 in)
Weight
771: 260G, (9.1 oz.)
772, 773: 410 g, (14.4 oz)
Vibration
Random 2 g, 5 to 500 Hz
Shock
1 meter drop test (except the jaw)
EMI/RFI
Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient
0.01% ¨¬C
(<18¡É or > 28¡É)
Power, battery life
771: (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
, 772 and 773: (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty
Three years for electronics
one year for cable and clamp assembly

Functional Specifications
mA measurement (Measured by clamp) 771 /772 / 773
Resolution and Range: 0 to 20.99 mA
Accuracy: 0.2% +2 counts
Resolution and Range: 21.0 mA to 100.0 mA
Accuracy: 1% + 5 counts
mA measurement (Measured in series with test jacks) 772/773
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% +2 counts
mA source (Maximum mA Drive: 24 mA into 1,000 ohms) 772/773
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% +2 counts
mA simulate (Maximum voltage 50 V dc) 772/773
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% +2 counts
Voltage source (2 mA maximum drive current)) 773 only
Resolution and Range: 0 to 10.00 V dc
Accuracy: 0.2% +2 counts
Voltage measure 773 only
Resolution and Range: 0 to 30.00 V dc
Accuracy: 0.2% +2 counts

 

 
Model name Description
 Fluke 771  Milliamp Process Clamp Meter

Included accessories:
  • Soft Carrying Case
  • Users Manual

 Fluke 772  Milliamp Process Clamp Meter

Included accessories:
  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap

 Fluke 773  Milliamp Process Clamp Meter

Included accessories:
  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap

 

 

 Resources
PDF File – Requires Adobe Reader Technical Data Sheet
PDF File – Requires Adobe Reader Instruction Sheet
PDF File – Requires Adobe Reader Supplement Instruction Sheet
PDF File – Requires Adobe Reader Application Note
PDF File – Requires Adobe Reader Instrument Security Procedures
 Product Details
 Part Number: View part numbers
 Accessories: View accessories
 Your browsing history
 Milliamp Process Clamp Meter
 Power Quality Clamp Meter
 Fluke 330 Series Clamp Meters
 Trend Link
 Software extension kit
Copyright © 2012 Alpha Controls & Instrumentation Inc..  All rights reserved.