Power Quality Clamp Meter (345)
Manufacturer: Fluke
 
Price: $2,076.00 (USD)
Stock Status: 2 to 3 weeks

This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.

Applications

  • Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
  • Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
  • Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
  • Load studies - Verify electrical system capacity before adding loads

Features

  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
  • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
  • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
  • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
  • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
  • 3-Phase power: Built in capability for balanced loads
  • View graphs and generate reports: Use power analyzer with included Power Log software
  •  

    Power Quality Clamp Meter
     
    Display
    Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight

    Power supply
    Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
    Battery life typically
    > 10 hours (backlight on full)
    > 12 hours (backlight reduced)
    Battery Eliminator BE345
    Input 110/230 V 50/60 Hz
    Output 15 V dc, 300 mA

    Ambient conditions (For indoor use only)
    Reference conditions
    All accuracies stated at 23¢ªC ¡¾ 1¢ªC (73.4 ¡ÆF ¡¾ 1.8 ¡ÆF)
    Operating temperature
    0 ¡ÆC to 50 ¡ÆC (32 ¡ÆF to 122 ¡ÆF)
    Temperature coefficient of current
    ¡Â ¡¾ 0.15 % of rdg per ¡ÆC
    Temperature coefficient of voltage
    ¡Â ¡¾ 0.15 % of rdg per ¡ÆC
    Maximum relative humidity
    80 % for temperatures up to 31 ¡ÆC (87 ¡ÆF) decreasing linearly to 50 % relative humidity at 40 ¡ÆC (104 ¡ÆF)
    Maximum operating altitude
    2000 m

    Electrical safety
    Maximum safe working voltages
    Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2
    Protection IP40; EN60529
    Current measurement
    600 V ac rms or dc between uninsulated conductor and ground
    Voltage measurement
    600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)

    EMC
    Emission
    IEC/EN 61326-1:1997 class A
    Immunity
    IEC/EN 61326-1:1997 Annex C Performance Criterion B

    Mechanical
    Dimensions (length x width x depth)
    300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
    Weight including batteries
    820 g/1.8 lb
    Jaw opening
    60 mm
    Jaw capacity
    58 mm diameter
    Cleaning
    The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.

    Electrical data
    All accuracies stated at 23 ¡ÆC ¡¾ 1 ¡ÆC (73.4 ¡ÆF ¡¾ 1.8 ¡ÆF). See Ambient conditions specifications for temperature coefficients.

    Current measurement (dc, dc rms, ac rms)
    Measuring range
    0 to 2000 A dc or 1400 ac rms
    Autorange facility
    40 A / 400 A / 2000 A
    Resolution
    10 mA in 40 A range
    100 mA in 400 A range
    1 A in 2000 A range
    Accuracy: DC and dc rms
    I > 10 A: ¡¾ 1.5 % rdg ¡¾ 5 digits
    I < 10 A: ¡¾ 0.2 A
    Accuracy: AVG
    I > 10 A: ¡¾ 3 % rdg ¡¾ 5 digits
    I < 10 A: ¡¾ 0.5 A
    Accuracy: Pk
    I > 10 A: ¡¾ 5 % rdg ¡¾ 5 digits
    I < 10 A: ¡¾ 0.5 A
    Accuracy: AHr
    I > 10 A: ¡¾ 2 % rdg ¡¾ 5 digits
    I < 10 A: ¡¾ 0.5 AHr
    Accuracy: CF (Crest Factor)
    1.1 ¡Â CF < 3: ¡¾ 3 % rdg ¡¾ 5 digits
    3 ¡Â CF < 5: ¡¾ 5 % rdg ¡¾ 5 digits
    Resolution: 0.01
    Accuracy: RPL (Ripple)
    2 % ¡Â RPL < 100 %: ¡¾ 3 % rdg ¡¾ 5 digits
    100 % ¡Â RPL < 600 %: ¡¾ 5 % rdg ¡¾ 5 digits
    Resolution: 0.1 %
    Idc > 5 A, Iac > 2 A
    All measurements dc and 15 Hz to 1 kHz
    Maximum overload 10,000 A or rms x frequency < 400,000
    Amps rms is a true-rms measurement (ac + dc)

    Voltage measurement (dc, dc rms, ac rms)
    Measuring range
    0 to 825 V dc or ac rms
    Autorange facility
    4 V / 40 V / 400 V / 750 V
    Resolution
    1 mV in 4 V range
    10 mV in 40 V range
    100 mV in 400 V range
    1 V in 750 V range
    Accuracy: DC and dc rms
    V > 1 V: ¡¾ 1 % rdg ¡¾ 5 digits
    V < 1 V: ¡¾ 0.02 V
    Accuracy: AVG
    V > 1 V: ¡¾ 3 % rdg ¡¾ 5 digits
    V < 1 V: ¡¾ 0.03 V
    Accuracy: Pk
    V > 1 V: ¡¾ 5 % rdg ¡¾ 5 digits
    V < 1 V: ¡¾ 0.03 V
    Accuracy: CF (Crest Factor)
    1.1 ¡Â CF < 3: ¡¾ 3 % rdg ¡¾ 5 digits
    3 ¡Â CF < 5: ¡¾ 5 % rdg ¡¾ 5 digits
    Resolution: 0.01
    Accuracy: RPL (Ripple)
    2 % ¡Â RPL < 100 %: ¡¾ 3 % rdg ¡¾ 5 digits
    100 % ¡Â RPL < 600 %: ¡¾ 5 % rdg ¡¾ 5 digits
    Resolution: 0.1 %
    Vdc > 0.5 V, Vac > 0.2 V
    All measurements dc and 15 Hz to 1 kHz
    Maximum overload 1,000 V rms
    Volts rms is a true-rms measurement (ac + dc)

    Harmonics
    THD (Total Harmonic Distortion)
    1 % ¡Â THD < 100 %: ¡¾ 3 % rdg ¡¾ 5 digits
    100 % ¡Â THD < 600 %: ¡¾ 5 % rdg ¡¾ 5 digits
    Resolution: 0.1 %
    DF (Distortion Factor)
    1 % ¡Â DF < 100 %: ¡¾ 3 % rdg ¡¾ 5 digits
    Resolution: 0.1 %
    H02 ¡Â Vharm < H13: ¡¾ 5 % ¡¾ 2 digits
    H13 ¡Â Vharm ¡Â H30: ¡¾ 10 % ¡¾ 2 digits
    All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz)
    Frequency range of fundamental F0 15 Hz to 22 Hz and 45 Hz to 65 Hz
    Vacrms > 1V

    Watts measurement (single- and three-phase) (dc, dc rms, ac rms)
    Measuring range
    0 to 1650 kW dc or 1200 kW ac
    Autoranging facility
    4 kW, 40 kW, 400 kW, 1650 kW
    Resolution
    1 W in 4 kW
    10 W in 40 kW
    100 W in 400 kW
    1 kW in 1200 kW
    Accuracy
    2.5 % rdg ¡¾ 5 digits
    W1¨ª < 2 kW ¡¾ 0.08 kW
    W3¨ª < 4 kW ¡¾ 0.25 kW

    VA measurement (single- and three-phase) (dc, dc rms, ac rms)
    Measuring range
    0 to 1650 kVA dc or 1200 kVA ac
    Autorange facility
    4 kVA, 40 kVA, 400 kVA, 1650 kVA
    Resolution
    1 VA in 4 kVA
    10 VA in 40 kVA
    100 VA in 400 kVA
    1 kVA in 1200 kVA
    Accuracy
    VA > 2 kVA: 2.5 % rdg ¡¾ 5 digits
    VA < 2 kVA: ¡¾ 0.08 kVA

    VAR measurement (single- and three-phase)
    Measuring range
    0 to 1250 kVAR
    Autorange facility
    4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR
    Resolution
    1 VAR in 4 kVAR
    10 VAR in 40 kVAR
    100 VAR in 400 kVAR
    1 kVAR in 1200 kVAR
    Accuracy
    VAR > 4 kVAR: ¡¾ 2.5 % rdg ¡¾ 5 digits
    VAR < 4 kVAR: ¡¾ 0.25 kVAR
    Power factor range
    0.3 < PF < 0.99

    Power factor (single- and three-phase)
    Measuring range
    0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5¡Æ capacitive to 0¡Æ and 0¡Æ to 72.5¡Æ inductive)
    Resolution
    0.001
    Accuracy
    ¡¾ 3¡Æ
    Frequency range
    15 Hz to 1 kHz

    Displacement power factor (single- and three-phase)
    Measuring range
    0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5¡Æ capacitive to 0¡Æ and 0¡Æ to 72.5¡Æ inductive)
    Resolution
    0.001
    Accuracy
    ¡¾ 3¡Æ
    Frequency range
    15 Hz to 22 Hz and 45 Hz to 65 Hz

    Kilowatt hour (kWHr)
    Measuring range
    40,000 kWHr
    Autorange facility
    4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr
    Resolution
    1 WHr in 4 kWHr Range
    10 WHr in 40 kWHr Range
    100 WHr in 400 kWHr Range
    1 kWHr in 4,000 kWHr Range
    10 kWHr in 40,000 kWHr Range
    Accuracy
    kWHr > 2 kWHr: ¡¾ 3 % ¡¾ 5 digits
    kWHr < 2 kWHr: ¡¾ 0.08 kWHr
    All Watts /VA /VAR /PF measurements
    Frequency range: DC and 15 Hz to 1 kHz
    Current range: 10 A to 1400 A rms
    Voltage range: 1 V to 825 V rms
    Maximum input: 825 V rms/1400 A rms
    Maximum overload: 1000 V rms/10,000 A All measurements dc and 15 Hz to 1 kHz. Maximum overload 10,000 A or rms x frequency < 400,000

    Frequency measurement (from current or voltage sources)
    Measuring range
    15 Hz to 1 kHz
    Resolution
    0.1 Hz
    Accuracy
    15 to 22 Hz ¡¾ 0.5 % rdg
    40 Hz to 70 Hz ¡¾ 0.5 % rdg
    15 Hz to 1000 Hz ¡¾ 1% rdg
    Current range
    10 A to 1400 A rms
    Voltage range
    1 V to 825 V rms

    Scope function
    Current measurement
    Ranges: 10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A
    Resolution: 1 A in 40 A
    10 A in 400 A
    50 A in 2000 A
    Accuracy: ¡¾ 3 % rdg ¡¾ 1 pixel
    Maximum overload: 10,000 A
    Voltage measurement
    Ranges: 4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V
    Resolution: 100 mV in 4 V
    1 V in 40 V
    10 V in 400 V
    31.25 V in 1000 V
    Accuracy: ¡¾ 2 % rdg ¡¾ 1 pixel
    Maximum overload: 1000 V rms
    Frequency range: DC and 15 Hz to 600 Hz
    Time base
    2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
    Refresh rate
    0.5 seconds
    Maximum sampling rate
    15.625 kHz

    Inrush current function
    Ranges
    40 A, 400 A, and 2000 A
    Resolution
    10 mA in 40 A range
    100 mA in 400 A range
    1 A in 2000 A range
    Accuracy
    I > 10 A: ¡¾ 5 % rdg ¡¾ 1 pixel
    I < 10 A: ¡¾ 0.5 A
    All measurements dc and 15 Hz to 1 kHz
    Maximum overload
    Maximum overload 10,000 A or rms x frequency < 400,000
    Amps rms is a true-rms measurement (ac + dc)
    Capture time
    1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
    Maximum sampling rate
    15.625 kHz

    Interface
    USB Interface to a PC
    Power Log software for download, analysis and reporting
    345 Upgrade Utility for installing a new firmware version

    Logging Memory
    Logging areas
    Three areas that can be used individually or combined into one large area
    Averaging periods
    1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom

    Logging Times
    Volts and current mode
    Average time Logging time (1 area)
    1 s 1 h 49 m
    2 s 3 h 38 m
    5 s 9 h 6 m
    10 s 18 h 12 m
    3
     Resources
    PDF File – Requires Adobe Reader Data Sheet
    PDF File – Requires Adobe Reader Users Manual
     Product Details
     Part Number: View part numbers
     Your browsing history
     Power Quality Clamp Meter
     Milliamp Process Clamp Meter
     Power Quality Clamp Meter
     Fluke 330 Series Clamp Meters
     Trend Link

    Copyright © 2012 Alpha Controls & Instrumentation Inc..  All rights reserved.