Earth Ground Tester (Model 1621)
Manufacturer: Fluke
 
Price: $1,077.00 (USD)
Stock Status: 4 to 5 weeks
Earth Ground Tester for resistance measurement

The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.


Features


  • 3-pole Fall-of-Potential earth testing for basic measurements

  • 2-pole resistance measurements for added versatility

  • Easily capture values with single-button operation

  • Ensure accurate measurements with automatic ‘noise’ voltage detection

  • Hazardous voltage warning offers increased user protection

  • Clearly read and record data with a large, backlit display

  • Rugged holster and design for tough work environments

  • Portable size allows for easy transportation

  • Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting

  • 600 V Cat II

  •  

    Earth Ground Tester
     
    General specifications
    Measuring functions
    3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage
    Intrinsic error
    Refers to the reference temperature range and is guaranteed for one year
    Measuring rate
    2 measurements/second
    Battery[1]
    One 9 volt alkaline (LR61)
    Battery condition
    LO-BAT is displayed if voltage drops below 6.5 V
    Voltages
    Between jacks H/C2 and E/C1: 250 Veff maximum (effective voltage)
    Between jacks S/P2 and E/C1: 250 Veff maximum
    Climatic class
    VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
    Temperature performance[2]
    Working: -10 °C to +50 °C (+14 °F to +122 °F)
    Operating: 0 °C to +35 °C (+32 °F to +95 °F)
    Storage: -20 °C to +60 °C (+68 °F to +140 °F)
    Reference: +23 °C ± 2 °C (+73 °F ± 4 °F)
    Temperature coefficient
    ± 0.1 % of range per degree Kelvin
    Safety
    IEC/EN 61010-1, 600 V CAT II, pollution degree 2
    Dimensions
    113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster
    Weight
    850 g (1.9 lb), including standard accessories, volume approximately 600 cm3
    Note:
    [1]If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage.
    Note:
    [2]The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use.

    Electrical specifications
    Maximum deviations:
    E1 Influence factor Position
    E1 Deviation influence 0 %
    E2 Influence factor Supply voltage
    E2 Deviation influence 0 %
    E3 Influence factor Temperature E3
    E3 Deviation influence 2.3 %
    E4 Influence factor Serial interference voltage (20 V)
    E4 Deviation influence 0.6 %
    E5 Influence factor Probe- and auxiliary probe resistance
    E5 Deviation influence 10 %
    Test voltage
    3.7 kV
    Protection type
    IP 40; IEC/EN 60529
    Electromagnetic compatibility
    Emission: IEC/EN 61326 Class B
    Immunity: IEC/EN 61326 Annex C
    RE resistance measurement
    Measuring method Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5
    Open circuit voltage 23 to 24 V ac
    Short circuit current > 50 mA ac
    Measuring frequency 128 Hz
    Maximum permissible overload 250 Veff
    Measuring time
    8 seconds (average from when START is pressed)
    Limit input
    Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient)
    Automatic changeover of resolution
    RH < 7 kÙ
    Resolution 0.01 Ù
    RH < 50 kÙ
    Resolution 0.1 Ù
    RH > 50 kÙ
    Resolution 1 Ù
    Interference voltage display dc + ac
    Vmax 30 Veff
    Common mode rejection > 80 dB at 50 Hz and 60 Hz
    Ri 680 kÙ
    Measuring uncertainty < 10 % for pure ac and dc signals

    Measuring range
    0.15 Ù to 20 Ù
    Resolution 0.01 Ù
    Display range 0 to 19.99 Ù
    200 Ù
    Resolution 0.1 Ù
    Display range 20 to 199.9 Ù
    2 kÙ
    Resolution 1 Ù
    Display range 200 to 1999 Ù
    Intrinsic uncertainty
    ± (6 % of measured value + 5D)
    Operating uncertainty IEC 61557[1]
    ± (18 % of measured value + 5D)
    Notes:
    [1] Covers all deviations caused by influence quantities E1-E5.
    If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes.
    Measured values are outside of the specified operating uncertainty.

     

     

     Resources
    PDF File – Requires Adobe Reader User's Manual
     Product Details