Product Description
Records time and date stamped DC voltage data. Accepts voltage signals from strain gauges, load cells and other low-level, DC voltage sources. Perfect for monitoring stress, torque, strain, pressure conditions and data from many other sensors/transducers. User-programmable Engineering Units and offset/gain calculations allows data to be presented in Volts, milliVolts, microVolts as well as the proper units being measured. Four voltage ranges are available. (±10mV, ±25mV, ±100mV and ±1000mV) Single channel, screw terminal input.
Specifications
Bridge
| Nominal Range |
±10 |
±25 |
±100 |
±1000 |
| Measurement Range |
±15mV |
±37.5mV |
±150mV |
±1200mV |
| Resolution |
1ìV |
2.5ìV |
5ìV |
50ìV |
| Calibrated Accuracy at 25°C |
±.25% FSR |
±.10% FSR |
±.05% FSR |
±.01% FSR |
| Input Range |
0 to 2.5V |
| Reference Voltage |
2.5V |
General
| Memory |
32,767 |
| Reading Rate |
1 second up to 12 hours |
| Baud Rate |
57,600 |
| Battery Life |
10 years |
| Material |
ABS Plastic |
| Dimensions |
1.7" x 2.7" x 0.8" (44mm x 69mm x 21mm) |
| Operating Environment |
-40~+80°C, 0~95%RH non-condensing |
| Required Interface Package |
IFC110 or IFC200 |