Loop-Powered Rate Totalizers (PD684 & PD689)
Manufacturer: Precision Digital
 
Starting at: $259.00 (USD)
Stock Status: 1 to 2 weeks
Features
  • 4-20 mA Input
  • 5 Digit LCD, 0.6" (15.2 mm) High
  • Overflow Displays Total up to 8 Digits
  • Programmable Alternating Rate/Total Display
  • FM Type 4X, IP65 Front
  • Shallow Depth Case 3.2" Behind Panel
  • 2 V Drop (5.7 V with Backlight)
  • Loop-Powered Backlight Standard
  • Custom Engineering Units & Bargraph
  • Square Root or Programmable Exponent
  • Non-Volatile Memory - No Battery Needed
  • Maximum & Minimum Display
  • Operating Temperature Range: -20 to 65°C
  • Intrinsically Safe & Non-Incendive
  • Open Collector Alarm or Pulse Output
  • HART Protocol Transparent
Loop-Powered Rate/Totalizer Approvals
 
Introduction
These loop-powered rate/totalizers can display rate up to five digits and total up to eight digits using the total overflow feature described below. The display can be programmed to automatically or manually toggle between rate and total. Standard features include a backlit display with bargraph, on-screen custom engineering units, max/min display and open collector output. There are two models available: the PD684 is for general-purpose applications and the PD689 is for hazardous area applications.

Even with all the features packed into these meters, they're still easy to setup and get running. Everything is programmed from the front panel buttons with no pots or jumpers to deal with. In fact, these indicators can be scaled without a signal source for even quicker setup.

 
The PD684 and PD689 go just about anywhere with their shallow-depth case, FM Type 4X front, loop-powered backlighting, and wide operating temperature range. It doesn't matter if they're indoors or outdoors, in bright sunlight, or a dimly lit plant, wet, dirty, hot or cold. And the PD689, with its FM Approval and CSA Certification, can be installed in just about any hazardous location.

Square root and programmable exponent functions are standard features on the PD684 and PD689. With these features, these indicators can display flow rate and total from a DP transmitter or open channel flow in weirs and flumes.
Loop-Powered Rate Totalizers
 

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Faceplate Display

Key Features

Through significant innovation in technology and design, we developed the Loop Leader™ Series of loop-powered rate/totalizer that is loaded the standard features and build tough for all environments.

Full Featured
Everything comes standard with these meters. The competition may charge extra for for loop-powered backlighting, open collector output and programmable exponent capability, but these and a host of other key features are standard on these indicators.

Install Just About anywhere
Indoors, outdoors, bright sunlight, dimly lit plant, wet, dirty, hot or cold- these indicators go just about anywhere. Their shallow-depth case, FM Type 4X front, loop-powered backlighting, and wide operating temperature range are all standard features. And the PD689 with its FM Approval and CSA Certification can be installed in just about any hazardous location.

4-20 mA Input Connections
Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Wiring Diagrams

Alternating Rate & Totalizer Display
Press Enter/ACK button to alternate between rate and total or program the totalizer so the display automatically changes between displaying rate and total every 10 seconds. This feature is particularly useful if the meters are mounted inside a NEMA 4X or an explosion-proof enclosure.




Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Alternating Rate & Totalizer Display Function
Square Root Function
Square Root Function
The square root extraction feature displays flow rate by extracting the square root from a differential pressure transmitter signal. The user selectable low-flow cutoff feature gives a reading of

   •Displays Flow Rate
   •User Selectable Low-Flow Cutoff
   •Only 2 Calibration Points Required

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Square Root Function

 

Programmable Exponent

The programmable exponent function is used to linearize the level signal in applications using weirs and flumes and display flow rate in engineering units.

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: open channel flow weirs and flume function


Totalizer Conversion Factor

The totalizer conversion factor is a number which is multiplied by the rate to compute total. For example, if the rate display is gallons per hour and total is desired in liters, a factor of 3.7843 should be used. If the display is gallons per hour and total is desired in gallons, a factor of 1 should be used.
Total & Overflow Display
This feature allows the PD684 & PD689 to display total values up to eight digits. This sample shows a total of 68,923,684.

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™ : Total & Overflow Display Function

Alarm Condition
After an alarm tripped simply press the ACK button for 3 seconds to acknowledge the alarm or wait for the alarm to reset automatically.

 Loop-Powered Rate/TotalizerPD684-PD689 Loop Leader™ : Alarm Condition


Setup and Programming

Easy Setup

Even with all the features packed into these meters, they’re still easy
to setup and get running. Everything is programmed from the front
panel buttons with no pots or jumpers to deal with. In fact, these
meters can be scaled without a signal source for even quicker setup
.

Main Menu
The Main menu consists of the most commonly used functions: Setup, Program, and Password

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Setup and Programming Menu
Advanced Features Menu Isolated Open Collector Output
To simplify the set up process, functions not needed for most applications are located in the Advanced Featured menu. Press and hold the Menu button for 5 seconds to access the advanced features of the meter.

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Advanced Programming Menu
The open collector output may be assigned as a pulse or alarm output. As a pulse output this feature will produce one pulse output per a given number of counts (user select). For example, these meters can be programmed to produce one pulse for every 500 gallons totalized. This output can be sent to a PLC or a counter. As an alarm output this feature allows high or low rate indication or total setpoint indication.

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Isolated Open Collector Output Diagrams

 

Installation
There is no need to remove the meter from its case to complete the installation, wiring, and setup of the meter.
Mounting Dimensions

Loop-Powered Rate/Totalizer PD684-PD689 Loop Leader™: Mounting Dimensions

Notes:

  1. Panel cutout required: 3.622 x 1.772 (92 x 45)
  2. Panel thickness: 0.040 – 0.250(1.0 – 6.4)
  3. Mounting brackets lock in place for easy mounting
Optional Field Enclosures

Enclosures available for one to six meters
Loop-Powered Rate/Totalizer PD684-PD689 within PDA2706 NEMA 4 Enclosure
PDA2706 NEMA 4 Enclosure
Shown with Six PD684 Meters
Loop-Powered Rate/Totalizer PD684-PD689 within PDA2801 Low-cost NEMA 4X Enclosure

PDA2801 Low-cost NEMA 4X Enclosure
Shown with One PD684

Specifications

General
Display: 5 digit LCD (-99999 to 99999), 0.60" (15.2 mm) high, 7-segment, automatic lead zero blanking.
Engineering Units: 0.25" (6.4 mm) high, 14-segment.
Bargraph: 20-segment, 0% to 100% indication.
Trend arrows: Up and down trend indication.
Backlight: Bright orange (intensity varies with signal)
Front Panel: FM Type 4X, IP65; panel gasket provided
Display Update Rate: 2.5/second
Overrange: Display flashes 99999
Underrange: Display flashes -99999
Programming Method: Four front panel buttons
Noise Filter: Programmable from 1 to 199
Recalibration: Recommended at least every 12 months.
Max/Min Display: Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password: Programmable password restricts modification of programmed settings.
Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Voltage Drop: 2.0 V max w/o backlight, 5.7 V max with backlight
Equivalent Resistance: 125 Ù @ 20 mA without backlight, 315 Ù @ 20 mA with backlight.
Normal Mode Rejection: 64 dB at 50/60 Hz
Operating temperature range: -20 to 65°C
Allowable temperature range: -40 to 65°C* (see note below)
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing
Connections: Screw terminals accept 12 to 22 AWG wire
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: gray
Mounting: 1/8 DIN panel cutout required. Two panel mounting bracket assemblies provided.
Tightening Torque: 4.5 lb-in (0.5 Nm) Screw terminal connectors
Overall Dimensions: 4.68" x 2.45" x 3.79" (119 x 62 x 96 mm)
Weight: 5.7 oz (162 g)
Warranty: 3 years parts and labor
Extended Warranty: 1 or 2 years

Input
Input Range: 4-20 mA
Accuracy: ±0.03% of span ±1 count, square root and programmable exponent: 10-100% FS.
Calibration: Scale without signal or calibrate with signal source
Calibration Range: User programmable over entire range of meter
Minimum Span: 0.40 mA between input 1 and input 2
Note: An Error message will appear if input 1 and input 2 signals are too close together.
Input Overload: Over current protection to 2 A max.
Decimal Point: Up to 4 places (d.dddd, dd.ddd, ddd.dd, dddd.d, or ddddd)
Function: Linear, square root, or programmable exponent
Low-Flow Cutoff: -99999 to 99999 (-99999 disables cutoff function)
Temperature Drift: 50 PPM/°C from -40 to 65°C ambient


Totalizer Features
Total Display: 0 to 99,999 main total display plus 0 to 999 total overflow for a combined 8 digit total of 99,999,999.
Alternating Display: Display may be programmed to alternate between rate and total every 10 seconds.
Time Base: Seconds, minutes, hours, or days
Totalizer Conversion Factor: 0.0001 to 99999
Totalizer: Calculates total based on rate, time base of second, minute, hour, or day, and field programmable multiplier; stored in non-volatile memory upon power loss.
Totalizer Rollover: Total rolls over when total exceed 99,999,999.
Totalizer Reset: Manual reset or automatic with time delay, or disabled for non-resettable total applications
.

Open Collector Output
Rating: Isolated open collector, 30 VDC @ 175 mA max.
Alarm Output: Assign to rate or total, high orlow rate alarm.
Deadband: 0-100% of full scale, user selectable
Acknowledge: ACK button resets output and screen indication.
Automatic Reset: Alarm resets automatically when signal reaches the reset point.
Pulse Output: 250 pulses/sec max; pulse width: 3 ms, fixed. If the pulse output exceeds the maximum pulse output, counts are accumulated as pending and are not lost. One pulse per total increment, programmable from 0.0001 to 99999 (decimal point based on total selection).

 

 

 Resources
PDF File – Requires Adobe Reader Data Sheet
PDF File – Requires Adobe Reader Instruction Manual
 Product Details
 Part Number: View part numbers
 Your browsing history
 Loop-Powered Rate Totalizers
 Hatchet NEMA 4X Loop-Powered Process Meter
 5 Digit Loop-Powered Panel Meters with Backlight
 4 1/2 Digit NEMA 4X FM & CSA
 3 1/2 Digit NEMA 4X FM & CSA Approved
Copyright © 2012 Alpha Controls & Instrumentation Inc..  All rights reserved.