ProtEX-One Explosion-Proof Loop-Powered Process Meter (PD6870)
Manufacturer: Precision Digital
 
Starting at: $479.00 (USD)
Stock Status: 1 to 2 weeks

Features


  • 4-20 mA input

  • 1 V drop (4 V with backlight)

  • 3½ digits LCD, 1" high

  • Loop-powered backlight option

  • Explosion-proof, IP68, NEMA 4X enclosure

  • Flanges for wall or pipe mounting

  • Easy calibration and installation

  • Operates from -40 to 75°C

  • INTRODUCTION


    The PD6870 is a rugged, loop-powered meter with 1" display digits in an explosion-proof enclosure for demanding applications in hazardous areas or in the harshest environmental conditions. The meter derives all of its power from the 4-20 mA loop with a small 1 volt drop for easy installation in almost any system.



    It is programmed using four easy to access front-mounted control dials with no complex or difficult to read programming menus necessary for setup. The numeric display will read from -1999 to 1999 over a 2000 count user adjustable scaling span. The backlight option lets you see the display under any lighting condition and is powered from the 4-20 mA loop with no additional power supply required.



    The enclosure is provided with two threaded conduit holes and integrated pipe or wall mounting slotted flanges.



     


    CONNECTIONS



    PD6800 Input Connections with Loop-Powered Backlight



    PD6870 Input Connections with Loop-Powered Backlight





     


    DIMENSIONS



    PD6870 Mounting Dimensions

     


    SPECIFICATIONS


    Except where noted all specifications apply to operation at +25°C.





    General


    Display: 3½ digit LCD, 1" (25.4 mm); -1999 to 1999

    Display Update Rate: 2.5 Updates/Second

    Overrange: Display reads 1 on the left most digit

    Programming Method: Four front mounted rotary control dials accessed when the cover is removed.

    Recalibration: Recommended at least every 12 months.

    Normal Mode Rejection: 60 dB rejection ratio

    Operating Temperature Range: -40 to 75°C

    Storage Temperature Range: -40 to 75°C

    Relative Humidity: 0 to 90% non-condensing

    Connections: Screw terminals accept 12 to 22 AWG wire

    Enclosure: Explosion-proof die cast aluminum with glass window, 0.30% max copper content, corrosion resistant epoxy coating, color: blue. NEMA 4X, IP68. Two ¾" NPT threaded conduit openings. One ¾" NPT nickel plated brass conduit plug with 10 mm hex key fitting installed.

    Mounting: May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting.

    Overall Dimensions: 5.65" x 5.25" x 4.86"

    (144 mm x 133 mm x 124 mm) (W x H x D)

    Weight: 5.00 lbs (80 oz, 2.27 kg)

    Warranty: 3 years parts and labor





    Input


    Input: 4-20 mA

    Accuracy: ±0.1% of full span ±1 count

    Temperature Drift: 150 PPM/°C from -40 to 75°C ambient

    Decimal Point: User selectable decimal point

    Calibration Range: 4 mA input: -1000 to +1000; 20 mA between 20 and 2000 counts greater than 4 mA display. Two point linear display span.

    Maximum Voltage Drop: 1 VDC @ 20 mA with backlight; 4 VDC @ 20 mA with loop-powered backlight

    Input Overload: Over current protection to 2 A max.





    Enclosure Approvals


    FM & CSA: FM Approved & CSA Certified. Explosion-proof for use in Class I, Division 1, Groups B, C, and D; Dust-Ignition-proof for Class II, Division 1, Groups E, F, and G, Class III; hazardous (classified) locations, indoor and outdoor (Type 4X and IP66)

    USA: Indoor and outdoor (Type 4X and IP66); Ta=-40°F to +185°F

    FM Certificate: 3032880

    Canada: Indoor and outdoor (Type 4X); Ta=-40°C to +85°C

    CSA Certificate: 2210414

    ATEX & IECEX: ATEX Certified: Group 2, Category 1 (Zone 1), Gases, Vapors, Mists, or Dusts: II 2 G D, Ex d IIC Gb, Ex tb Db IIIC IP68.

    Ta=-40°C to +85°C. ATEX Certificate: Sira 08ATEX1325U

    IECEx Certified: Flameproof, Gas Group IIC, Ex d IIC Gb, Ex tb IIIC IP68.

    Ta=-40°C to +85°C. IECEx Certificate: IECEx SIR 08.0126U


     

    ProtEX-One Explosion-Proof Loop-Powered Process Meter
     
     Resources
    PDF File – Requires Adobe Reader Data Sheet
    PDF File – Requires Adobe Reader Instruction Manual
     Product Details
     Part Number: View part numbers