ProtEX Pro LOOP-POWERED PROCESS METER (PD6800)
Manufacturer: Precision Digital
 
Price: $599.00 (USD)
Stock Status: 1 to 2 weeks

Features


  • 4-20 mA Input Loop-Powered

  • Modern, Sleek and Practical Enclosure

  • 5-Digit, 0.7" (17.8 mm) Upper Display

  • 7 Alphanumeric Character, 0.4" (10.2 mm) Lower Display

  • SafeTouch® Through-Glass Button Programming

  • Password Protection

  • 32-Point , Square Root, or Exponential Linearization

  • Loop or External DC-Powered Backlight Standard

  • 3.0 V Drop (6.0 V with Backlight)

  • Explosion-Proof, IP68, NEMA 4X Enclosure

  • Flanges for Wall or Pipe Mounting

  • HART® Protocol Transparent

  • Operates from -40 to 75°C

    Overview


    The new ProtEX-Pro PD6800 explosion-proof process meter brings modern design, easy readability, and enhanced functionality to hazardous areas around the world in a way never seen before. Competitors have lost sight of the fact that the primary thing customers want to do with meters such as these is to look at them. Customers want a meter that looks nice so they can be proud to install it in their facility. And they want a meter with a display that provides the important information about their process, can be seen under varied lighting conditions, from wide angles, and from a distance. The PD6800 delivers all these and more. Spend a few minutes reviewing the features described in the graphic below and you will see how!






    ProtEX-Pro PD6800 Feature Callouts

    Key Features


    Informative & Easy to Read Display


    The high contrast, backlight LCD display is easy to read from far away and under various lighting conditions. The upper display is 0.7" high and shows 5 digits of flow rate. The lower display is 0.4" high and shows either flow total or a tag with 7 alphanumeric characters. And best of all, the display is mounted right up against the glass so it can be seen from a wide viewing angle.


    Through-Glass SafeTouch® Buttons


    The PD6800 is equipped with four sensors that operate as through-glass buttons so that it can be programmed and operated without removing the cover (and exposing the electronics) in a hazardous area. These buttons can be disabled for security by selecting the LOCK setting on the switch located on the connector board in the base of the enclosure. To actuate a button, press one finger to the glass directly over the marked button area. When the cover is removed, four mechanical buttons located next to the sensors are used.


    Modern, Sleek and Practical Enclosure


    The first thing customers notice about a product is its enclosure and the ProtEX-Pro really shines here. The copper-free (0.30%), smooth, die-cast aluminum NEMA 4X (IP68) enclosure is finished with a corrosion resistant epoxy coating that literally does make the ProtEX-Pro shine. The built-in mounting flanges make for convenient wall or pipe mounting and there is even a slot on the back of the enclosure for centering on the pipe. There are two ¾" NPT conduit holes for wiring.


    Wide Viewing Angle


    Customers can't always look at the display from straight on, so the window and display module have been optimized to provide a wide viewing angle of approximately +/- 40°; nearly twice the competition! Remember, the PD6800 is designed to be looked at.



    PD6800 Wide Viewing Angle

    Environmentally Tough


    The ProtEX™ Series not only looks great with their modern, smooth die cast aluminum enclosures, but they can be installed virtually anywhere. The NEMA 4X / IP68 enclosure provides serious protection from the elements, high impact, corrosion and electrical interference and the extensive, worldwide agency approvals means they can be installed virtually anywhere.


    Perfect & Secure Fit Every Time


    The internal cast rails ensure the ProtEX assembles together perfectly, quickly and securely; and everything lines up for optimal viewing every time. There are no standoffs to worry about breaking or getting out of alignment. Two spring-loaded, self-retaining, thumbscrews make the assembly a snap, while pressing the LCD as close to the glass as possible to improve wide angle viewing.


    Input Signal Conditioning


    Live Input Calibration


    In lieu of meter scaling, the meter can be calibrated with a precision signal source. While applying a precision signal, the relative scale value is entered via the front panel. This is done at any two points along the scale. Using this method, the operator can set a "best fit straight line" for non-linear input spans.


    Multi-Point Linearizer


    Up to 32 linearization points can be selected under the Linear function. The multi-point linearization can be used to linearize the display for non-linear signals such as those from level transmitters used to measure volume in odd-shaped tanks or to convert level to flow using weirs and flumes that require a complex exponent. These points are established via direct entry


    or with an external calibration signal


    .


    Square Root Extraction


    The square root extraction function displays flow rate by extracting the square root from a differential pressure transmitter signal. The user selectable low-flow cutoff feature gives a reading of zero when the flow rate drops below a user selectable value.



    open channel flow application with PD6800 explosion proof loop powered meter

    Programmable Exponent


    The programmable exponent function is used to linearize the level signal in open channel flow applications using weirs and flumes and display flow rate and units of measure.


     


     


     


     


     

  • ProtEX Pro LOOP-POWERED PROCESS METER
     

    Additional Features

    Password Protection

    A 5-digit password prevents unauthorized changes to the programmed parameter settings. The lock symbol is displayed to show that settings are protected. If the meter is password protected, the meter will display the message LOCKED when the Menu button is pressed.

    Alarm Indication

    The PD6800 has high or low alarm indication. When in alarm, the display will flash, and a HI or LO symbol is displayed. The alarm has an adjustable deadband (the difference between the set and reset points). The alarm is acknowledged by pressing the ENTER/ACK button.

    Installation

    Installation Flexibility

    The PD6800's rotatable display/meter module along with two available conduit connections provide for numerous installation options. The display can be rotated in 90° increments. Rotate it 90° for horizontal mounting. Wiring can then be routed to either the top conduit connection, or from below to the opposite conduit connection (metal conduit plug supplied). Use both conduit connections for through-wiring in any plane.

    PD6830 Installation Flexibility

    Easy Wiring & Service

    Unscrew the two captured thumb screws and unplug a connecting cable and the display/meter module is simply and completely removed. A heavy duty terminal block is then easily accessed and wired. It is clearly marked to prevent wiring errors. The display/meter module can be removed without breaking the loop. As such, it can be serviced without the need to uninstall the entire product.

    PD6800 explosion Proof Loop powered meter wiring

     

    Connections

    To access the wiring connections, remove the enclosure cover and unscrew the two captive screws that fasten the display module. Disconnect the ribbon cable and remove the display module. Power and signal connections are made to a terminal block at the base of the enclosure. Grounding connections are made to the two ground screws provided on the base – one internal and one external.

    PD6800 Connection Diagram

     

    Specifications

    Except where noted all specifications apply to operation at +25°C.

    General

    Display: Upper: Five digits (-9999 to 99999) 0.70" (17.8 mm) high, 7-segment, automatic lead zero blanking. Lower: Seven characters 0.4" (10.2 mm) high, 14 segment alphanumeric. Symbols: for high & low alarm, Password Lock. Backlight: White
    Decimal Point: Upper process display has up to four decimal places or none: d.dddd d.ddd, d.dd, d.d, or ddddd
    Display Update Rate: Ambient > -25°C: 2 Updates/Second. Ambient < -25°C: 1 Update/5 Seconds
    Display Orientation: Display may be mounted at 90° increments up to 270° from default orientation.
    Overrange: Display flashes 99999
    Underrange: Display flashes -9999
    Programming Method: Four SafeTouch® through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
    Noise Filter: Programmable - Lo, Med, Hi, or Off
    Recalibration: Recalibration is recommended at least every 12 months.
    Max/Min Display: Max/Min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
    Password: Programmable password restricts modification of programmed settings.
    Advanced Functions: Live input calibration, linearization, square root, or programmable exponent
    Alarm Indication: Flashing display plus HI/LO indicators
    Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
    Normal Mode Rejection: 64 dB at 50/60 Hz
    Operating Temperature Range: -40 to 75°C.
    Storage Temperature Range: -40 to 85°C.
    Relative Humidity: 0 to 90% non-condensing
    Connections: Screw terminals accept 12 to 22 AWG wire
    Enclosure: Explosion-proof die-cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA 4X, 7, & 9, IP68. Copper-free (0.3%). Two ¾" NPT threaded conduit openings. One ¾" NPT metal conduit plug with 12 mm hex key fitting installed.
    Mounting: May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting.
    Overall Dimensions: 5.65" x 5.25" x 4.86" (W x H x D) (144 mm x 133 mm x 124 mm)
    Weight: 5.00 lbs (80 oz, 2.27 kg)
    Warranty: 3 years parts and labor

    Input

    Input range: 4-20 mA
    Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span.
    Temperature Drift: 50 PPM/°C
    Decimal Point: User selectable decimal point
    Calibration Range: An error message will appear if input 1 and input 2 signals are too close together. Input Range: 4-20 mA. Minimum Span Input 1 & Input 2: 0.10 mA
    Maximum Voltage Drop: 3.0 VDC @ 20 mA without loop-powered backlight. 6.0 VDC @ 20 mA with loop-powered backlight
    Equivalent Resistance: 150 Ω @ 20 mA without loop-powered backlight. 300 Ω @ 20 mA with loop-powered backlight
    Input Overload: Over current protection to 2 A max.
    External Loop Power Supply:
    Voltage Range Maximum Power
    9-30 VDC 9 VDC 12 VDC 24 VDC 30 VDC
      0.2 W 0.25 W 0.5 W 0.75W

    Product Ratings & Approvals

    FM: Explosion-proof for use in Class I, Division 1, Groups B, C, D. Class II, Division 1, Groups E, F, G. Class III, Division 1; T6. Class I, Zone 1, AExd IIC T6 Gb. Zone 21, AEx tb IIIC T85°C. Ta=-40 to 75°C.
    Enclosure: Type 4X & IP66. Certificate number: 3040391
    ATEX: II 2 G D. Ex d IIC T6 Gb. Ex tb IIIC T85°C Db IP68. Ta=-40 to 75°C.
    Certificate number: Sira 10ATEX1116X
    IECEx: IECEx SIR 10.0056X. Ex d IIC T6 Gb. Ex tb IIIC T85 C Db IP68. Ta=-40 to 75°C
    CSA: Class I, Division 1, Groups B, C, D. Class II, Division 1, Groups E, F, G. Class III, Division 1; T6. Class I, Zone 1, Ex d IIC T6.
    Ta=-40 to 75°C. Enclosure: Type 4X & IP66.
    Certificate number: 11 2325749

    Dimensions

    PD6800 Mounting Dimensions

     

     

     

     

     Resources
    PDF File – Requires Adobe Reader Data Sheet
    PDF File – Requires Adobe Reader Instruction Manual
     Product Details
     Part Number: View part numbers
     Your browsing history
     ProtEX Pro LOOP-POWERED PROCESS METER
     Precision Digital Test Pressure Gauges
     Industrial Digital Pressure Gauges
     General Purpose Digital Pressure Gauge
     1/4 DIN Limit Controller