Advanced Humidity / Temperature Data Logger (HygroLog NT)
Manufacturer: Rotronic
 
Models

Probe Options

Docking Stations


The HygroLog NT and associated HW4 software comply with FDA CFR part II regarding electronic record keeping. The HygroLog NT can be networked to the purpose of monitoring and capturing data from several locations to a PC. On-site data logging by the HygroLog NT, combined with the capability of automatically downloading log files to the PC, provides protection against loss of data in the event of a power outage or network failure. Using a docking station, up to 7 probes and two external contacts can be connected to a single HygroLog NT.


  • Relative humidity, temperature, dew point or other calculated parameter

  • Multi-probe capability, wide selection of probes to satisfy every application

  • Measurements from  0 to 100%RH and -50..200°C /-58..392°F (with external probe)

  • Optional internal humidity-temperature probe, protected against unauthorized removal

  • Monitoring of up to two external contacts (door, relay contact, etc.)

  • Optional LC display and multi-function keypad

  • Large recording capacity with removable flash memory card

  • Operates with a 9 VDC standard or rechargeable battery

  • Data download without interrupting the measurements

  • Full featured, Windows based ROTRONIC HW4 software. Optional OPC tags allow importing data into practically any third-party OPC client application

  • Interchangeable humidity-temperature HygroClip probes for fast and easy maintenance



Models


Which HygroLog NT is right for you?


HygroLog NT2 Key Features


  • Measures and records humidity, temperature and calculated parameter (see list below)

  • Available with or without display and keypad

  • Internal humidity-temperature probe designed to prevent unauthorized removal

  • Measuring range: 0..100%RH and -50..200°C (-58..392°F) when probe is separated from logger with a cable (depends on probe model)

  • Large recording capacity with removable flash memory card

  • Full probe adjustment functions directly from keypad

  • Interchangeable humidity-temperature HygroClip probe for fast and easy maintenance

  • Remote mode allows model with display and keypad to read/configure models w/o display and keypad (see connector on top of the logger)

  • Available with Bluetooth transceiver (display and keypad required)

  • Complies with FDA 21 CFR Part II when used together with the





    ROTRONIC HW4 software

  • The optional docking station adds the following features (depends on docking station model):


  • Up to 4 additional external probes: HygroClip probes, third party analog probes or 4-wire RTD

  • Monitoring of up to two external contacts (door, relay contact, etc.)

  • Power provided by an AC adapter

  • Data download without interruption of the measurements

  • Networking (RS485 or Ethernet)






    HygroLog NT3 Key Features


  • All the features of the HygroLog NT2 + 2 additional probe inputs (HygroClip probes)






    The optional docking station adds the following features (depends on docking station model):


  • Up to 4 additional external probes: HygroClip probes, third party analog probes or 4-wire RTD

  • Monitoring of up to two external contacts (door, relay contact, etc.)

  • Power provided by an AC adapter

  • Data download without interruption of the measurements

  • Networking (RS485 or Ethernet)






    Model Numbers:


    Basic models without display and keypad

    HYLOG-NT2: includes internal HygroClip S probe



    HYLOG-NT2-NP: data logger only (without internal HygroClip S probe)




    HYLOG-NT3: includes internal HygroClip S probe



    HYLOG-NT3-NP: data logger only (without internal HygroClip S probe)






    Models with display and keypad

    HYLOG-NT2D: includes internal HygroClip S probe



    HYLOG-NT2D-NP: data logger only (without internal HygroClip S probe)



    HYLOG-NT3D: includes internal HygroClip S probe



    HYLOG-NT3D-NP: data logger only (without internal HygroClip S probe)






    Models with internal Bluetooth transceiver (display and keypad included)

    HYLOG-NT2D-BT: includes internal HygroClip S probe HYLOG-NT2D-BT-NP: data logger only (without internal HygroClip S probe) HYLOG-NT3D-BT: includes internal HygroClip S probe





    HYLOG-NT3D-BT-NP: data logger only (without internal HygroClip S probe)

    Calculated Parameter:


    Each probe input of the HygroLog NT2 and NT3 (or docking station) can be individually configured to calculate and record one of the following parameters:


  • Dew point (Dp)

  • Frost point (Fp)

  • Wet bulb temperature (Tw)

  • Enthalpy (H)

  • Vapor concentration (Dv)

  • Specific humidity (Q)

  • Mixing ratio by weight (R)

  • Vapor concentration at saturation (Dvs)

  • Vapor partial pressure (E)

  • Vapor saturation pressure (Ew)






    Internal Probe:

    The Internal probe of the HygroLog NT2 and NT3 is a HygroClip S. Models with an internal probe ship with the probe retracted for maximum probe protection.



    For a faster response, the internal probe can be extended as shown on the picture to the left. This is done by opening the HygroLog NT (instructions are provided in the user manual).



    If so desired, the probe can also be separated from the HygroLog NT with a length of cable.


    Top

  • Advanced Humidity / Temperature Data Logger
     

    Probe Options

    Portable Probes (Handheld)


    HygroClip S


    HygroClip S (internal or external probe for HygroLog NT2 / NT3)

    for measurement in air, max. 85ºC (185ºF), wire mesh filter
    length: 100mm (3.9"), d: 15mm (0.6")


    HygroClip SP05

    for measurement in air ducts, max. 85ºC (185ºF)
    tube length: 200mm (7.9"), d: 5mm (0.2")
    cable: 2m (6.5ft)

    HygroClip SC05

    HygroClip SC05

    for measurement in tight spaces, max. 100ºC (212ºF)
    diameter: 5mm (0.2"), cable: 2m (6.5ft)

    HygroClip HK25 / HK40

    HygroClip HK25 / HK40

    air probe for measurement at high temperature
    HK25: max. 150ºC (212ºF) / HK40: max. 200ºC (392ºF)
    wire mesh filter
    tube length: HK25: 250 (9.8") / HK40: 400mm (15.7"), d: 15mm (0.6")
    cable: 2m (6.5ft)

    HygroClip HP28 tubular probe

    HygroClip HP28 insertion probe

    for measurement of materials in bulk, max. 85ºC (185ºF)
    sintered steel filter
    tube length: 280 (11"), d: 10mm (0.4")
    cable: 2m (6.5ft)

    HygroClip HS28 sword probe

    HygroClip HS28 sword probe

    for measurement of paper stacks/rolls, max. 85ºC (185ºF)
    blade length: 280 (11"), w: 18mm (0.7"), th.: 4mm (0.16")
    cable: 2m (6.5ft)

    Note: the above probes have a 5-pin DAT-05 connector. Extension cable MOK-02-DAT05 can be used to connect any of the above probes to input 1 of the HygroLog NT2 / NT3 (this input is normally used for an internal HygroClip S probe). Adapter cable MOK-02-B5 is required to connect any of the above probes to inputs 2 and 3 the HygroLog NT3 or to inputs 4 to 7 of the docking station (see Accessories).

    Fixed Installed Probes  


    HygroClip IC-1
    (100mm) / IC-3 (250mm)
    for through wall installation, PPS body, wire mesh filter
    -50...200ºC (-58...392ºF)
    body: length: 100/250mm (3.9/9.8"), d: 15mm (0.6")
    cable: 2m (6.5ft)


    HygroClip IM-1
    (120mm) / IM-3 (270mm)
    recommended for high humidity, high temperature applications
    for through wall installation, stainless steel body, wire mesh filter
    -50...200ºC (-50 ...392ºF)
    body: length: 120/270mm (4.7/10.6"), d: 15mm (0.6")
    cable: 2m (6.5ft)


    HygroClip IE-1
    (G1/2 ") / IE-3 (NPT1/2 ")
    for pressurized applications max. 50 bar (725 PSI)
    sintered stainless steel filter
    applications at ambient temperature, survives -50...85ºC (-58...185ºF)
    cable: 2m (6.5ft)

    Note: the above probes have a 7-pin connector. An adapter cable such as the T7-03-B5 is required for connection to inputs 2 and 3 the HygroLog NT3 or to inputs 4 to 7 of the docking station (see Accessories). Extension cable mod. AC1616 is not compatible with the HygroLog NT.

     

    Top

    Docking Stations

    The HygroLog NT requires a docking station for any of the following:

    • Mount the HygroLog NT to a wall
      (logger can be secured to docking station with a padlock)

    • Place the HygroLog on the optional desk-top stand

    • Use an external AC adapter to power the HygroLog NT

    • Connect the HygroLog NT to a PC via a serial port (RS232)
      or a USB port

    • Connect the HygroLog NT to an Ethernet network
      (TCP/IP protocol) - wired or wireless

    • Connect up to 4 additional probes to the HygroLog NT
      Monitor up to two external contacts (relay, door, etc.)

    • Connect up to 64 HygroLog NT together in a multi-dropped arrangement (RS-485)

    • Control up to 2 relay outputs

    • Access the HygroLog NT from a web browser

    HygroLog NT3 with docking station

    HygroLog NT3 with docking station and desk stand

    Models Primary Interface Description / Function
    DS-NT1

    None

    This model simply allows mounting the HygroLog NT to a wall and powering it with the AC adapter
    DS-NT2

    RS-232

    RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher).
    DS-NT3

    USB

    RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)
    DS-NT4 Ethernet (RJ45 wired) RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)
    DS-NT4WEB Ethernet (RJ45 wired) Internal web server can be accessed from a web browser without requiring the HW4 software.
    DS-NT4-WL Ethernet (wireless) RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)
    DS-U-1 RS-232 RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)

    Connects up to four HygroClip or single channel analog probe with voltage output, and up to two digital input signals (external contacts).
    DS-U-2 USB RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)

    Connects up to four HygroClip or single channel analog probe with voltage output, and up to two digital input signals (external contacts).
    DS-U-4 Ethernet (RJ45 wired) RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)

    Connects up to four HygroClip or single channel analog probe with voltage output, and up to two digital input signals (external contacts)..
    DS-U4WEB Ethernet (RJ45 wired) Internal web server can be accessed from a web browser without requiring the HW4 software.

    Connects up to four HygroClip or single channel analog probe with voltage output, and up to two digital input signals (external contacts).

    DS-U4-420 Ethernet (RJ45 wired) RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher)

    Connects up to four single channel analog probes with 4...20 mA signal, and up to two digital input signals (external contacts).

    DS-U4WEB-420 Ethernet (RJ45 wired) Internal web server can be accessed from a web browser without requiring the HW4 software.

    Connects up to four single channel analog probes with 4...20 mA signal, and up to two digital input signals (external contacts).

    DS-PT-2 USB RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher).

    Connects up to four RTD probes (direct 4-wire connection), and up to two digital input signals (external contacts).

    DS-PT-4 Ethernet (RJ45 wired) RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher).

    Connects up to two RTD probes (direct 4-wire connection), and up to two digital input signals (external contacts).

    DS-PT-4-WL Ethernet (wireless) RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher).

    Connects up to two RTD probes (direct 4-wire connection), and up to two digital input signals (external contacts).

    DS-R1

    USB

    RS-485 interface allows connecting up to 63 additional ROTRONIC devices in a multi-drop arrangement (requires HW4 professional or higher).

    Two independent relay contacts and connections for up to two digital input signals (external contacts)..

    Notes:
    • All above models feature a receptacle for the AC1211 power adapter (not included with the docking station).
    • Use of the AC adapter is required for all models with an Ethernet interface and is strongly recommended whenever several probes are connected to the data logger and docking station.
    • By nature, models with an Ethernet interface generate enough heat to noticeably increase the temperature of both the docking station and data logger. Any probe connected to the HygroLog NT should be separated by a length of cable to ensure accurate temperature and humidity data.

     

     Resources
    PDF File – Requires Adobe Reader Data Sheet
    PDF File – Requires Adobe Reader Product Manual
    PDF File – Requires Adobe Reader Air Chip 3000
     Your browsing history
     Advanced Humidity / Temperature Data Logger
     EAxx-SCS Humidity Standard (Box of 5)
     Toxic Gas Detection Transmitter/Sensors
     Combustible Gas Detection Transmitter/Sensors
     CO2 Gas Detection Transmitter/Sensors
    Copyright © 2012 Alpha Controls & Instrumentation Inc..  All rights reserved.