| HW3 Set: PC Based System (HygroLab 2) |
| Manufacturer: Rotronic |
| |
|
Overview
Probe
HW3 Software
HW3 Water Activity Software
Ordering Information
Ultra fast water activity measurement of up to 4 product samples simultaneously
Get higher productivity in your laboratory and greater flexibility of use
at a lower cost per measurement point
- AwQuick Mode - accelerated water activity measurement: the average time required to measure a product sample can be reduced to less than a minute by running 4 probes simultaneously
- Standard Mode: conventional water activity measurement with automatic detection of equilibrium and the option to record / graph the data
- Automatic capture of the end values to a text file to facilitate record keeping. Each record includes product description, probe identification, date and time.
Includes 2 sizes of sample holders and disposable sample cups, humidity calibration standards, etc. HygroLab 2 indicator accepts a large choice of probes, suitable for the direct measurement of products in bulk and other applications
Overview
|
| The HygroLab 2 Set consists of the following: |
|
- HygroLab 2 indicator
- AC adapter (115 VAC / 9 VDC)
- AW-DIO probe for the measurement of product samples
- WP14 sample holder (shallow)
- PS14: pack of 100 disposable sample cups (14mm deep)
- WP40 sample holder (deep)
- PS40: pack of 100 disposable sample cups (40mm deep)
- 1 box each EA00 (0 %RH), EA10 (10 %RH), EA35 (35 %RH), EA80 (80%RH) and EA95 (95%RH) humidity calibration standards
- HW3 software on a CD (code to access water activity functions already entered)
- RS232 cable for connection to the COM port of a PC
HW3 is a software package developed by ROTRONIC. HW3 is shipped on a CD ROM and requires a PC with the Microsoft Windows operating system. Access to the water activity functions of HW3 requires both a HygroLab 2 indicator and a product key (access code) that is sold separately.
Connect up to 4 probes to the HygroLab 2 indicator. Use a standard serial cable to connect the RS232 port of the HygroLab to the COM port of a PC (or laptop). Install the HW3 software on the PC, enter the product key and you are ready to go.
Probes
| standard probe - included in set |
|
 |
HygroClip AW-DIO
for measurement of product samples
Requires use of a sample holder and disposable sample cups
(included in set - click on the link Probe Accessories, above).
Note: additional probes, sample holders and disposable cups can be ordered as a AW-DIO probe set
|
| additional probes - order separately |
|
 |
HygroClip HP28 insertion probe
for the direct measurement of materials in bulk: powders, granules, grain and seeds
max. 85ºC (185ºF)
sintered steel filter
tube length: 280 (11"), d: 10mm (0.4")
cable: 2m (6.5ft) |
 |
HygroClip SC05
for measurement in tight spaces such as inside a product package
max. 100ºC (212ºF)
diameter: 5mm (0.2"), cable: 2m (6.5ft) |
 |
HygroClip HS28 sword probe
for measurement of packaging materials such as paper or cardboard stacks/rolls
max. 85ºC (185ºF)
blade length: 280 (11"), width: 18mm (0.7"), thickness: 4mm (0.16")
cable: 2m (6.5ft)
|
|
|
|
| |
|
HW3 Software
Calibration
| The digital HygroClip probes can be calibrated and adjusted at one or more points with the HygroLab indicator:
• For a quick check of the probe and eventual 1-point adjustment of humidity and temperature, you can plug a
freshly calibrated probe into any free probe input and adjust against this probe.
• For scheduled maintenance, you can adjust temperature at up to 2 points and humidity at up to 4 point against
physical references.
You may also make use of the full interchangeability of the HygroClip digital probes and rotate the probes with a calibration laboratory. The calibration laboratory can do any of the following:
|
- Use the HygroLab 2 indicator to directly calibrate and adjust the probe
- Connect the probe to an MOK-03-WIN or B5-03-WIN cable and adjust the probe using a PC
on which the HW3 software has been installed
|
|
HW3 Software: software based probe calibration is both simple and precise: there are no hard-to-reach, hard-to-adjust potentiometers. HW3 offers a high level of flexibility in selecting the calibration reference, giving the user complete control over the calibration process. HW3 features the following calibration modes:
• Humidity: 2, 3 or 4 points
• Temperature: 2 points
• 1-point adjustment function (offset) for both humidity and temperature
When humidity calibration is done using the ROTRONIC humidity standards, HW3 automatically corrects the value of the standard to reflect the temperature of calibration (see note). HW3 also offers the possibility of printing a certificate of calibration.
Note: the value of the standards does not depend on barometric pressure (altitude). |
|
Certified Humidity Standards: if you do not have access to a humidity generator, the ROTRONIC humidity standards offer a reliable and convenient way to generate a reference humidity condition during probe calibration. The ROTRONIC standards are shipped with an internationally accepted certificate, meeting in full the requirements of quality systems such as ISO9000. The standards are available in boxes of 5 glass ampoules of the same value, and can be stored indefinitely. Standards in the range of 5 to 95 %RH are non-saturated aqueous salt solutions. The 0 %RH humidity standard is made of small granules of a highly porous ceramic. A Material Safety Data Sheet is available for each standard. |
|
Calibration Devices: some of the probes used with the HygroLab 2 may require a calibration device to hold the humidity standard. This device is a small airtight container that fits on the probe and seals around the humidity sensor. During calibration, a known reference humidity is produced inside the calibration device by means of a humidity standard.
Four calibration devices are available for the HygroClip probes:
ER-15 for 15mm diameter probes
ER-05 for 5mm diameter probes |
|
| ORDERING INFORMATION |
| Order code: |
Description: |
Order code: |
Description: |
| HW3 |
HW3 software package |
EA00-SCS |
0.5%RH cal. std, SCS Certificate, pack 5 |
| |
|
EA05-SCS |
5%RH cal. std, SCS Certificate, pack 5 |
| |
|
EA10-SCS |
10%RH cal. std, SCS Certificate, pack 5 |
| MOK-03-WIN |
Cable HygroLab probe to PC |
EA11-SCS |
11.3%RH cal. std, SCS Certificate, pack 5 |
| B5-03-WIN |
Cable AwVC-DIO probe to PC |
EA20-SCS |
20%RH cal. std, SCS Certificate, pack 5 |
| |
|
EA35-SCS |
35%RH cal. std, SCS Certificate, pack 5 |
| |
|
EA50-SCS |
50%RH cal. std, SCS Certificate, pack 5 |
| ER-15 |
Calibration device for 15mm diameter probes |
EA65-SCS |
65%RH cal. std, SCS Certificate, pack 5 |
| ER-05 |
Calibration device for 5mm diameter probes |
EA75-SCS |
75.3%RH cal. std, SCS Certificate, pack 5 |
| |
|
EA80-SCS |
80%RH cal. std, SCS Certificate, pack 5 |
|
|
|
EA95-SCS |
95%RH cal. std, SCS Certificate, pack 5
|
| |
|
|
|
|
|
|
|
|
HW3 Water Activity Software
System Requirements
| PC |
Pentium 233 MHz or better |
| Windows |
95, 98, Me or NT, 2000, XP |
| Memory |
32 MB or better |
| Disk Space |
20 MB |
| Monitor |
VGA or Super VGA |
| Resolution |
1024 x 768 recommended (800 x 600 minimum)
High Color 16 Bit or better (256 color minimum) |
| Connection |
RS232 (COM 1 - 4) |
| Software |
HW3 (includes Browser, Adobe Acrobat Reader) |
|
|