Applications
- High Accuracy General Purpose
- R & D Test and Measurement
- Vacuum Systems
- Dynamometers
- Engine Test Cells
| Model 204/C204 Specifications |
| Full Scale Pressure Output |
Model 204 (Voltage): 5 VDC |
Model C204 (Current): 20 mA |
| Zero Pressure Output |
0 VDC |
4 mA |
Accuracy (RSS Method) |
±0.11% Full Scale (0.073% Full Scale, optional, and ±0.14% Full Scale for 10,000 psig range) |
| Type of Pressure |
Gage Absolute Vacuum |
| Pressure Ranges |
0 to 25, 50, 100, 250, 500, 1000, 3000, 5000, 10000 psig 0 to 25, 50, 100, 250, 500, 1000, 3000, 5000 psia 0 to 14.7 psiv |
| Thermal Effects |
- Compensated Range °F (°C):
- 30 to 160 (-1 to 65)
- %FS/100°F(100°C)max.zero:
- ±0.4 (±0.7)
- %FS/100°F(100°C)max.span:
- ±0.3 (±0.5)
|
| Media |
Gases or liquids compatible with 17-4PH stainless steel. (Hydrogen not recommended for use with 17-4PH stainless steel) |