Nouveaux produits
Spéciaux
Donnés techniques
Mon Catalogue
Système qualité
Temps d'exécution
Soumission demandée
Séminaires
Carrieres
Sondage satisfaction
Alpha Contrôles et Instrumentation Inc.
 
Vous n’êtes pas loguer. SVP cliquez ici pour vous loguer.
(888) 621-3626
Accueil
Produits
Services d'étalonnages
Recherche
Liste des produits
Expositions
Contactez-nous
Panier à soumission
Mes commandes
Panier d'achats
Login
English

ABOUT SSL CERTIFICATES
FAIL (the browser should render some flash content, not this).
Produits»ACR»CO2 et gaz toxique
 
Enregistreur de donnés - qualité de l'air intérieur (IAQ-100)
Fabricant: ACR
 
Commençant à: $1,673.00 (USD)
Stock Status: 1 à 2 jours
The Indoor Air Quality logger combined with Telair 7001 monitor can record the three leading air indicators which are temperature, RH, and CO2.
Enregistreur de donnés - qualité de l'air intérieur
 
temperature, RH, Carbon Dioxide
IAQ - Indoor Air Quality 

Battery

3.6 volt Lithium, guaranteed for 10 years

Logger Resolution

8 bits (1 part in 256)

Number of Channels

  • one intrenal temperature sensor
  • one internal RH sensor
  • one for CO2 sensor
  • two for optional remote temp & RH sensor

Temperature Sensor Specification

  • NTC Thermistor; -40 to 70 °C (-40 to 158 °F)
  • accrracy: ±0.2 °C from 0 to 70 °C; ±0.5 °C from -40 to 0 °C (±0.36 °F from 32 to 158 °F; ±0.9 °F from 32 to -40 °F)

RH Sensor Specification

  • capacitive thin polymer film
  • ±4% from 10 to 90% (-20 to 40 °C [-4 to 104 °F])
  • better than 0.04% between 25 and 60% RH at 25 °C (77 °F)

CO2 Sensor Specification

  • response time: <60 seconds
  • accuracy: ±50 ppm or ±5% of reading, whichever is greater
  • warm up time: <60 seconds at 22 °C

PDF

Click Here

 

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: Noryl® Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use) Factory replaceable
Mounting: Magnetic backing or locking eyelet
Memory Size: 32 K (32,768 readings)
Sampling Method: 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates between 8 seconds to once every 5 days
Resolution: 8 bits (1 part in 256)
External Connector: Removable screw-type terminal strip with Common (-) connection
PC Requirements: IBM PC or 100% compatible running MS® Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"

 Ressources
Fichier PDF – requiert Adobe Reader Fiche technique
Fichier PDF – requiert Adobe Reader Livre d’instruction
 Informations
 No. de pièce: Voir no. de pièce
 Accessoires: Voir accessoires
 L'historique de votre navigation
 Enregistreur de donnés - qualité de l'air intérieur
 Four-Channel Relative Humidity Data Logger
 Single-Channel DC Current Data Logger
 Sterile Full-View Flow Indicator for Hygienic Applications
 Sterile View-Thru Flow Indicator for Hygienic Applications
Copyright © 2012 Alpha Contrôles et Instrumentation Inc..  Tous droits réservés.