Produits»Fluke»Accessories»Options
 
300 MHz Oscilloscope Calibration Option (5500A-SC300)
Fabricant: Fluke
 

 

Wide workload coverage gets even wider.

The SC300 enables the versatile 5500A and the enhanced performance 5520A to calibrate the most widely used analog and digital oscilloscopes up to 300 MHz. It is a plug-in module that fits inside the 5500A or 5520A Multi-Product Calibrator. It can be ordered factory installed with a new calibrator, or added later at a Fluke service center for an additional installation and calibration charge.

Fluke offers more ways to match the right oscilloscope calibration tools with your workload and budget. If your workload includes oscilloscopes above 300 MHz, you will want to take a look at the 5500A-SC600 option for the 5500A/5520A Multi-Product Calibrators or the 5500A-SC1100 option for the 5520A Multi-Product Calibrator. And if your workload includes primarily oscilloscopes above 600 MHz, see our 5820A dedicated oscilloscope calibrator.

Powerful functionality

The 5500A-SC300 option adds powerful functionality to the 5500A/5520A Multi-Product Calibrators:

  • Leveled sine wave generator up to 300 MHz for verifying bandwidth
  • Square wave generator for calibrating voltage gain
  • Fast edge risetime pulse generator (< 1 ns) for checking pulse response
  • Time mark generator for verifying horizontal deflection characteristics

Operation is easy

You access the SC300's capabilities simply by selecting "Scope" mode on the calibrator front panel. All outputs are conveniently located on the calibrator's output block, to make hook-ups easy and to minimize the errors contributed by cabling. There are no fragile, bulky pulse heads to contend with.

300 MHz Oscilloscope Calibration Option
 