Nouveaux produits
Spéciaux
Donnés techniques
Mon Catalogue
Système qualité
Temps d'exécution
Soumission demandée
Séminaires
Carrieres
Sondage satisfaction
Alpha Contrôles et Instrumentation Inc.
 
Vous n’êtes pas loguer. SVP cliquez ici pour vous loguer.
(888) 621-3626
Accueil
Produits
Services d'étalonnages
Recherche
Liste des produits
Expositions
Contactez-nous
Panier à soumission
Mes commandes
Panier d'achats
Login
English

ABOUT SSL CERTIFICATES
FAIL (the browser should render some flash content, not this).
Produits»Fluke»Accessories»Options
 
Power Quality Option (5520A-PQ)
Fabricant: Fluke
 

Calibrate power quality to the most exacting standards

The 5520A-PQ option enables the Fluke 5520A Multi-Product Calibrator to calibrate power quality instrumentation to the standards of the IEC and other regulatory agencies. Three precision waveform modes provide traceability for power meters, disturbance analyzers, power quality monitors, recorders and other power quality related equipment.

The PQ option increases the 5520A’s already impressive workload coverage, flexibility and ease of use. This is a rugged, portable instrument, ideal for use both in the field and on the bench. It is also affordable, allowing you to match your configuration to your workload and add options as that workload changes and grows.

The 5520A-PQ option can be ordered factory installed with a new calibrator or added to your existing 5520A at a local Fluke Service Center.

Three power quality modes are packed with features

The three power quality waveform modes in the 5520A-PQ include Composite Harmonic, Flicker Simulation, and Sags and Swells Simulation. These waveforms are available in either the single output mode (voltage or current) or dual output modes (voltage + current and voltage + voltage). The modes provide traceability for harmonic analysis, flicker, and sags and swells functions of power quality measurement instruments.

The PQ option adds powerful new functionality to the 5520A:
  • Fundamental generation combined with up to 15 harmonics, producing a “multi-tone” output to verify the performance of harmonic analyzers.
  • Flicker simulation to verify the performance of Flickermeters described in IEC 610000-4-15.
  • Sags and swells simulation to test power quality analyzers for one of the most critical parameters in an electrical distribution system.
  • Improved phase uncertainty over the standard 5520A sinewave modes, for calibrating higher precision wattmeters.

As in all 5520A calibrators, these functions also address your power calibration requirements:
  • Programmable phase angle between the two output channels (dual output modes) with .01 º resolution.
  • Phase locking of multiple 5520A calibrators for polyphase power testing.
  • Performance verification of both three- and four-wire wattmeters.
  • Compensation for inductive loads available in all current output modes.

Composite Harmonic Mode
This mode outputs a user defined waveform with up to 15 harmonics, from the 2nd up to the 63rd, that are combined with the fundamental. Both amplitude and phase of each harmonic, relative to the fundamental, can be specified. In the dual output modes (voltage + current and voltage + voltage), the wave shapes are independent of each other, but synchronized in time with 0.01 º phase resolution. Up to two user defined waveforms can be stored in non-volatile memory for easy recall. Two IEC 10003-2 waveforms (Class A and Class D current harmonic limits) are pre-defined for CE compliance testing.

Flicker Simulation Mode
Flicker simulation performs either a rectangular or sinewave amplitude modulation of the voltage or current output. The repeat frequency or repetition rate of the flicker event is programmable from 0.1 Hz to 30.0 Hz. The duty cycle of the flicker event relative to the nominal amplitude is programmable, giving true modulation of the output signal. Duty cycle ranges from 1 % to 99 %. The amplitude of the flicker event is programmable from +100.0 % of the base waveform. To check the IEC 61000-415 flicker function of power quality analyzers, six combinations of delta voltages and change frequencies are provided to quickly check for a Pst (Perceptionshort term) of 1.

Sags and Swells Simulation Mode
Sags and Swells simulation performs a one-time amplitude modulation of the voltage or current output. The amplitude is programmable from +100 % of the base waveform. The duration of the sag (also referred to as dip) or swell is adjustable from 0.005 to 60.000 seconds. The ramp period of the sag or swell may also be specified. The Sag and Swell event can be adjusted to occur from 0.0 to 99.999 seconds after the trigger event.

Power Quality Option
 
 Ressources
Fichier PDF – requiert Adobe Reader Operation Manual
Fichier PDF – requiert Adobe Reader Service Manual
 L'historique de votre navigation
 Power Quality Option
 MeterCleaner™ Wipes
 Dual Output Temperature Transmitter
 HC series toroidal conductivity sensor
 Chilled Mirror Transmitter
Copyright © 2012 Alpha Contrôles et Instrumentation Inc..  Tous droits réservés.