Nouveaux produits
Spéciaux
Donnés techniques
Mon Catalogue
Système qualité
Temps d'exécution
Soumission demandée
Séminaires
Carrieres
Sondage satisfaction
Alpha Contrôles et Instrumentation Inc.
 
Vous n’êtes pas loguer. SVP cliquez ici pour vous loguer.
(888) 621-3626
Accueil
Produits
Services d'étalonnages
Recherche
Liste des produits
Expositions
Contactez-nous
Panier à soumission
Mes commandes
Panier d'achats
Login
English

ABOUT SSL CERTIFICATES
FAIL (the browser should render some flash content, not this).
Produits»Fluke»Digital Multimeters»Electrical and HVAC
 
HVAC Multimeter with Temperature and Microamps (116)
Fabricant: Fluke
 
Prix: $221.00 (USD)
Stock Status: 2 à 3 semaines

Compact true-rms meter for HVAC (heating ventilation air conditioning) troubleshooting. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.

Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 117, the Electrician¡¯s Multimeter with Non-contact voltage.


Features


  • Built-in thermometer for HVAC applications

  • Microamps to test flame sensors

  • Low input impedance: helps prevent false readings due to ghost voltage

  • Large white LED backlight to work in poorly lit areas

  • Resistance, continuity, frequency and capacitance

  • Min/Max/Average with elapsed time to record signal fluctuations

  • Compact ergonomic design for one-handed operation

  • Compatible with optional magnetic hanger (ToolPak¢â)

  • CAT III 600 V safety rated

  •  

    HVAC Multimeter with Temperature and Microamps
     
    Specifications
    Maximum voltage between any terminal and earth ground
    600 V
    Surge protection
    6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
    Display
    Digital: 6,000 counts, updates 4 per second
    Bar graph
    33 segments, updates 32 per second
    Operating Temperature
    -10 ¡ÆC to + 50 ¡ÆC
    Storage Temperature
    -40 ¡ÆC to + 60 ¡ÆC
    Battery type
    9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life
    400 hours typical, without backlight

    Accuracy Specifications
    DC millivolts
    Range: 600.0 mV
    Resolution: 0.1 mV
    Accuracy: ¡¾ ([% of reading] + [counts]): 0.5% + 2
    DC volts
    Range/Resolution: 6.000 V / 0.001 V
    Range/Resolution: 60.00 V / 0.01 V
    Range/Resolution: 600.00 V / 0.1 V
    Accuracy: ¡¾ ([% of reading] + [counts]): 0.5% + 2
    Auto volts
    Range: 600.0 V
    Resolution: 0.1 V
    Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
    4.0 % + 3 (500 Hz to 1 kHz)
    AC millivolts1 true-rms
    Range: 600.0 mV
    Resolution: 0.1 mV
    Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    AC volts1 true-rms
    Range/Resolution: 6.000 V / 0.001 V
    Range/Resolution: 60.00 V / 0.01 V
    Range/Resolution: 600.0 V / 0.1 V
    Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    Continuity
    Range: 600 §Ù
    Resolution: 1 §Ù
    Accuracy: Beeper on < 20 §Ù, off > 250 §Ù; detects opens or shorts of 500 ¥ìs or longer.
    Ohms
    Range/Resolution: 600.0 §Ù / 0.1 §Ù
    Range/Resolution: 6.000 k§Ù / 0.001 k§Ù
    Range/Resolution: 60.00 k§Ù / 0.01 k§Ù
    Range/Resolution: 600.0 k§Ù / 0.1 k§Ù
    Range/Resolution: 6.000 M§Ù / 0.001 M§Ù
    Accuracy: 0.9 % + 1
    Range/Resolution: 40.00 M§Ù / 0.01 M§Ù
    Accuracy: 1.5 % + 2
    Diode Test
    Range/Resolution: 2.000 V / 0.001 V
    Accuracy: 0.9% + 2
    Capacitance
    Range/Resolution: 1000 nF / 1 nF
    Range/Resolution: 10.00 ¥ìF / 0.01 ¥ìF
    Range/Resolution: 100.0 ¥ìF / 0.1 ¥ìF
    Range/Resolution: 9999 ¥ìF / 1 ¥ìF
    Range/Resolution: 100 ¥ìF to 1000 ¥ìF
    Accuracy: 1.9% + 2
    Range/Resolution: > 1000 ¥ìF
    Accuracy: 5% + 20%
    LoZ capacitance
    Range: 1 nF to 500 ¥ìF
    Accuracy: 10% + 2 typical
    Temperature2 (Type-K thermocouple)
    Range/Resolution: -40 ¡ÆC to 400 ¡ÆC / 0.1 ¡ÆC
    Accuracy: 1% + 102
    Range/Resolution: -40 ¡ÆF to 752 ¡ÆF / 0.2 ¡ÆF
    Accuracy: 1% + 182
    AC ¥ìamps true-rms (45 Hz to 500 Hz)
    Range/Resolution: 600.0 ¥ìA / 0.1 ¥ìA
    Accuracy: 1.0% + 2
    DC ¥ìamps
    Range/Resolution: 600.0 ¥ìA / 0.1 ¥ìA
    Accuracy: 1.0% + 2
    Hz (V or A input)2
    Range/Resolution: 99.99 Hz / 0.01 Hz
    Range/Resolution: 999.99 Hz / 0.1 Hz
    Range/Resolution: 9.999 Hz / 0.001 Hz
    Range/Resolution: 50.00 Hz / 0.01 Hz
    Accuracy: 0.1% + 2

     Ressources
    Fichier PDF – requiert Adobe Reader 116 Users Manual
    Fichier PDF – requiert Adobe Reader 116C Users Manual