Fabricant: Hart Scientific
 

 

Features

  • Temperature range of 0°C to 1000°C 
  • Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C 
  • Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C 
  • Designed by Hart’s primary standards design team 

Specifications 

Range 

0°C to 1000°C 

Calibration Uncertainty 

±0.05°C at 962°C 

Long-term Drift (Rtpw) 

<0.01°C at 0°C/100 hours at 1000°C 

<0.06°C at 0°C/1000 hours at 1000°C 

Short-term Stability 

±0.005°C 

Immersion 

<153 mm (6") at 700°C 

Rtpw 

10 ohm (±1 ohm) 

Hysteresis 

<0.005°C from 0°C to 1000°C 

Thermocycling 

<0.01°C, 10 cycles from 0 to 1000°C 

Current 

1 mA 

Size 

6.35 mm (0.25")  O.D. 

Length 

508 mm (20") 

Sheath Material 

Alumina 

Weight 

1kg (2 lb.) 

Calibration 

Included 1913-6 fixed-point calibration 

At Hart, we receive many requests for precision PRT accuracy at thermocouple temperatures. Until now metrologist have settled for expensive, high-temperature SPRTs or inaccurate thermocouples for high-temperature measurement. 

We’re pleased to introduce the world’s finest high-temperature secondary PRT, our Model 5624. 

Ideal for use as a reference thermometer in high-temperature furnaces, the 5624 can reach a temperature of 1000°C with long-term drift at 0°C of 10 mK and accuracy (including short-term stability and calibration uncertainty over the full range) of 55 mK! Due to Hart Scientific’s proprietary sensor design, this PRT has short-term stability of 5 mK, and an immersion requirement of less than 153 mm (6") at 700°C. 

The 5624 is assembled in an alumina sheath that is 508 mm (20") long and 6.35 mm (0.25") in diameter. Several termination configurations can be selected to match different thermometer readouts. Each 5624 comes with a NIST-traceable, NVLAP-accredited fixed-point calibration from 0°C to 962°C. That’s a fixed-point calibration! The 5624 also comes in a protective carrying case.

 

 

High Temperature PRT
 
 Ressources
Fichier PDF – requiert Adobe Reader 5624 Data Sheet
Fichier PDF – requiert Adobe Reader 5624 User's Guide
 L'historique de votre navigation
 High Temperature PRT
 Freezer Probe
 Small Diameter Industrial PRT's
 Seconday Standard PRT's
 Secondary PRT with Calibration Options
Copyright © 2012 Alpha Contrôles et Instrumentation Inc..  Tous droits réservés.