Features
3½ Digit LCD Voltmeter
Blue LED Backlighting
200mV Full Scale Reading
9 Pin SIL Connection
IP65 Splashproof Protection
The SP 400-BLUE features a 200mV d.c. measurement range with auto-zero and auto-polarity. The module has a low battery warning and decimal points are user selectable. The SP 400-BLUE features a negative rail generator which enables the meter to measure a signal referenced to its own power supply GND. Blue LED backlighting ensures excellent readability under low light conditions. The module is easily fitted into the panel, using the fixing clip provided. The module's low cost means it will suit high and low volume applications. The design of the panel meter's housing ensures splash proofing using the supplied seal.
This is a popular part, normally stocked in high quantity and suitable for new designs.
| Specification |
Min. |
Typ. |
Max. |
Unit |
| Accuracy (overall error) * |
|
0.1 |
|
% (±1 count) |
| Linearity |
|
|
±1 |
count |
| Sample rate |
|
2.5 |
|
samples/sec |
| Operating temperature range |
0 |
|
50 |
°C |
| Temperature stability |
|
100 |
|
ppm/°C |
| Supply voltage |
V+ to GND configuration |
3.5 |
5.0 |
7.5** |
V d.c. |
| V+ to V- |
6.0 |
9.0 |
15.0** |
V d.c. |
| Supply current |
V+ to GND configuration |
|
350 |
|
uA |
| V+ to V- |
|
175 |
|
uA |
| Backlight supply voltage |
|
7.5*** |
8.0 |
V d.c. |
| Backlight supply current @ 7.5V d.c. |
|
9 |
|
mA |
| Input leakage current (Vin=0V) |
|
1 |
10 |
pA |
* To ensure maximum accuracy, re-calibrate periodically
** Operation of the meter beyond maximum supply voltage rating may cause permanent damage to the meter.
*** An external series resistor is required above 7.5V, see Application section of the data sheet
**** This specification linearly derates to 5mA @ 50°C