Simple but flexible display shows both flow rate and total
-40 to 80°C operational temperature
7 Digit LCD display offered with backlight
11 Digit Accumulated total with engineering units
Available with numerous enclosure options and minimal depth requirement
Clear menu structure that is universal across line
Contains 7 Digit K-Factor for tuning
All settings are stored in EEPROM for power failure protection
Differing measuring units may be chosen for flow and total
Offers a single relay alarm output for either a high or low flow alarm
The F013 display is a basic flow rate and totalizing meter with a high or low alarm. The total and flow rate are displayed together with large 0.67” (17mm) digits and smaller 0.31” (8mm) digits along with the units of measurement. If an alarm condition occurs it appears on the LCD and can be set to trigger the single relay output. Pressing the clear button twice will clear the running total. Accumulated total is shown after pressing the select key. The F013 has optional inputs including Pulse, Coil, NAMUR, 4-20 mA or 0-10 V. The F013 is offered with a plastic, aluminum, or explosion proof enclosure, or it can be ordered to simply panel mount. The options for powering the unit are battery, IS battery, loop power, 80-240 VAC with sensor supply, IS 16-30 VDC, and 8-24 VAC/VDC. The F013-XI can be used in hazardous areas too, classification EEx ia IIB T4.