Transmetteur thermo-hygrométrique météorologique (HygroFlex M)
Fabricant: Rotronic
 
- Designed for continuous data monitoring applications.
- Available with dew point, enthalpy or other calculated parameter.
- Fully interchangeable plug-in HygroClip S3 probe with durable, field proven Rotronic Hygromer™ humidity sensor.
- Operating temperature at probe: -40 to +85°C
- Analog and digital outputs permit signal transmission over long distances
- Networkable, user configurable
- Software based probe calibration with certified humidity standards.
- Available with natural aspiration radiation shield and mounting plate suitable for 1.5" diameter pole.
- Optional foam filter allows sensors to operate in coastal and marine environments. Aluminum enclosure is treated with special marine coating.
Transmetteur thermo-hygrométrique météorologique
 

Models

The HygroFlex M is available in two standard versions which share the following features:

• Interchangeable HygroClip S3 probe with 3 meter (9.8 ft) cable
• Fully user programmable
• Software based probe calibration and instrument configuration
• Internal test connector for HygroPalm calibrator
• 12...35 VDC / 12...24 VAC or 90...264 VAC power
HygroFlex M1 :

- %RH and temperature
-  Analog Outputs

HygroFlex M3: 

 - %RH, temperature and calculated value
   (dew-point, enthalpy, etc)
Analog & Digital Outputs

• Two linear analog outputs: 4-20 mA, 0-5V, etc.
• Jumper configuration of analog outputs signal type
• Analog outputs can be configured for practically any
  range
• Three linear analog outputs: 4-20 mA, 0-5V, etc.
• Jumper configuration of analog outputs signal type
• Analog outputs can be configured for practically any range
• RS232 output (optional cable grip)
• Networkable - see below
  RS232 first HygroFlex to PC
  RS485 between transmitters
• Optional input for analog pressure probe (restrictions apply)
  (optional cable grip)

Maximum network cable length: RS232: 150m (490ft) / RS485: 1,000m (3,300ft) between the two furthermost units

Probe

The HygroClip S3 combines advanced microprocessor and ASIC technology with a robust plug-in design to offer these unique features:

  • Well proven, accurate and durable sensors:
    Hygromer™ C94 capacitive humidity sensor
    Precision RTD temperature sensor
  • Digital and analog outputs
  • Operating range: 0...100%RH
    and -40...85°C/-40...185°F
  • Up to ±1.0%RH and ±0.2°C accuracy at 25°C with special (optional) calibration
  • Temperature compensated
  • Low heat absorption color
  • DC operation with low current consumption (< 4mA)
  • Signal transmission: up to 5 m / 16 ft with direct output, up to 100m / 325ft with signal amplifier
  • Large choice of connectors / signal adapters
  • Long term stability < 1%RH / year
  • Fully interchangeable: can be replaced in seconds with no loss of accuracy and no calibration

Technical Data
Humidity sensor ROTRONIC Hygromer® C94 (capacitive)
Temperature sensor RTD Pt100 Ohm, 1/3 DIN
Sensor protection Wire mesh filter (standard) / foam filter (optional)
Measuring range 0...100%RH and -40...85°C ( -40...185°F)
Operating limits same as measuring range
Accuracy at 23°C / 73°F ±1.5%RH and ±0.2°C / 0.4°F (when calibrated for HygroFlex M)
Repeatability better than 0.5%RH and 0.1°C/°F
Analog output signals
(minimum load > 10 k Ohm)
0...100%RH = 0...1V
- 40...85°C = 0...1.25V (-40...60°C = 0...1V)
Digital output/input signal 1-wire, HygroClip format, 2-way communication
Analog signal resolution 0.02%RH and 0.06°C
Digital signal resolution 0.004%RH and 0.004°C
Sampling time < 0.7 sec
Maximum cable length 5 m /15 ft for direct output
up to 100m / 325 ft with signal amplifier
Connection type bayonet cap on mounting connector (see accessories)
Protection grade IP65 (probe to connector)
Supply Voltage 3.5...50VDC
Current Consumption < 4mA
Minimum excitation time < 4 sec
EMC compatibility (CE) EN-50081-2, EN50082-2
Material Polycarbonate, white
Dimensions length: 100mm (3.94"), diameter: 15mm (0.59")
Weight 14 g / 0.5 oz

Probe Calibration


For scheduled maintenance, you may to want to rotate the probes (as opposed to the
complete instrument) between the measurement site and a calibration laboratory. The
HygroClip product line is designed to make this easy.

After removing the probe from the HygroFlex M transmitter, the following alternatives are available to calibrate the probe:

  1. Calibrate the probe using a HygroPalm 3 indicator
  2. Calibrate the probe using a PC on which the HW3 software has been installed (requires the MOK-03-WIN calibration cable to connect the probe to the PC).
  HW3 Software: software based probe calibration is both simple and precise: there are no hard-to-reach, hard-to-adjust potentiometers. HW3 offers a high level of flexibility in selecting the calibration reference, giving the user complete control over the calibration process. HW3 features the following calibration modes:

• Humidity: 2, 3 or 4 points
• Temperature: 2 points
• 1-point adjustment function (offset) for both humidity and temperature

When humidity calibration is done using the Rotronic humidity standards, HW3 automatically corrects the value of the standard to reflect the temperature of calibration (see note). HW3 also offers the possibility of printing a certificate of calibration.

Note: the value of the standards does not depend on barometric pressure (altitude).

 

Certified Humidity Standards:
if you do not have access to a humidity generator, the Rotronic humidity standards offer a reliable and convenient way to generate a reference humidity condition during probe calibration. The Rotronic standards are shipped with an internationally accepted certificate, meeting in full the requirements of quality systems such as ISO 9000. The standards are available in boxes of 5 glass ampoules of the same value, and can be stored indefinitely. Standards in the range of 5 to 95 %RH are non-saturated aqueous salt solutions. The 0 %RH humidity standard is made of small granules of a highly porous ceramic. A Material Safety Data Sheet is available for each standard.

 

Calibration Devices:
a calibration device is a small airtight container that fits on the probe and seals around the humidity sensor. During calibration, a known reference humidity is produced inside the calibration device by means of a humidity standard.

Four calibration devices are available for the HygroClip probes:
ER-15 for 15mm diameter probes
ER-05 for 5mm diameter probes
EM-15 for type ‘IE’ probes
ERV-15 for 15mm diameter probes (wall mounting)

Probe Calibration Accessories

MOK-03-WIN Calibration cable for HygroClip

HW3 Calibration software on CD ROM
ER-15 Calibration device for HygroClip
EAXX-SCS Certified humidity standards (5 per box)
XX = 00. 05, 10, 20, 35, 50, 65, 80, 95%RH

Installation

 

Software

HW3 is a software package designed for the HygroClip product line. HW3 features data acquisition, recording, graphing and alarm functions, calculation of various humidity parameters (both on-line and off-line) as well as instrument configuration and probe calibration. HW3 also offers a comprehensive solution for the networking of up to 32 HygroFlex M3 transmitters.


Network Display Form

• On-line presentation of the data in tabular form
• Up to 32 transmitters
• Up to 64 humidity and temperature probes
• Up to 192 measured and calculated values
• Live graph of up to 8 measured or calculated values
  with or without data logging
Data-logging

• Log interval adjustable from a few seconds to several hours
• Up to 32 instruments can be simultaneously recorded
• Individual log file per instrument or all instruments on the network
  in a single log file (requires Microsoft's Excel)
• Size of log file can be limited based on the number of samples or a new file
  can be automatically started each hour, day or month
• Display or print-out of the data in tabular format
• File data can be transferred to HW3 graphic module or to Microsoft's Excel
Alarm function

• Monitors relative humidity and / or temperature
• Can be set for individually for each instrument and probe on the network
• Acoustic and or visual signal directly on PC
• Remote alarm by email (requires Microsoft's Outlook)
Graphs

• On-line (live graph) or off-line (based on a log file)
• Can display calculated values: dew-point, mixing, ratio etc.
• Up to 16 traces simultaneously
Instrument Display Form

• On-line presentation of the data for a single transmitter
  (number of probes depends on the model and its options)
• Selection of the calculated parameter
• Access to data logging, graph and alarm functions
• Access to instrument configuration and probe calibration


Probe Calibration (HygroClip probes)

• Humidity: up to 4 points, Temperature: 2 points
• 1-point adjustment function (offset)
• Automatic temperature correction of the ROTRONIC humidity standards
• Certificate can be generated


System Requirements


PC




Pentium 233 MHz or better
Windows 95, 98, Me or NT, 2000
Memory 32 MB or better
Disk Space 20 MB
Monitor VGA or Super VGA
Resolution 1024 x 768 recommended (800 x 600 minimum)
High Color 16 Bit or better (256 color minimum)
Connection RS232 (COM 1 - 4)
Software HW3 (includes Browser, Adobe Acrobat Reader)

Datasheet

 L'historique de votre navigation
 Transmetteur thermo-hygrométrique météorologique
 Humidity Temperature Meteorological Probe
 Capteur météorologique thermo-hygrométique
 Humidity Temperature Transmitter (removable probe required)
 Humidity Temperature Transmitter (integral probe)
Copyright © 2012 Alpha Contrôles et Instrumentation Inc..  Tous droits réservés.