Fluke

116 / 62 MAX+ Technician's Combo Kit

Ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need


$342.00 CAD
Normally ships in 4-6 Weeks

 
  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Kit includes  the Fluke 116 HVAC Multimeter with Temperature and Microamps as well as the Fluke 62 MAX+ Infrared Thermometer.

Fluke 116 Digital Multimeter:
• TL175 Hard Point Test Lead Set
• TPAK ToolPak Magnetic Meter Hanging Strap
• Flexible Cuff Pipe Clamp Thermocouple
• 80BK Integrated Temperature Probe
• 80AK-A Thermocouple Adapter
• C115 Deluxe Soft Carrying Case with Shoulder Strap

Fluke 62 MAX+ Infrared Thermometer:
• Dust and water-resistant: IP54 rated
• Rugged: 3 m (9.8 ft) drop tested
• Ergonomically designed: Completely redesigned for a more natural hand fit
• Distance to spot: 12:1
• Dual lasers: Identifies area to be measured
• Large, backlit display: Makes data easier to read, even in dark areas

Fluke 116 HVAC Multimeter with Temperature and Microamps

Specifications

Maximum Voltage Between any Terminal and Earth Ground

600 V

Surge Protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2

Display

6,000 counts, updates 4 per s

Bar Graph

33 segments, updates 32 per s

Temperature

Operating

-10°C - 50°C

Storage

-40°C - 60°C

Battery Type

9 V Alkaline, NEDA 1604A/ IEC 6LR61

Battery Life

400 h typical, without backlight

 

Accuracy Specifications

DC Millivolts

Range

600.0 mV

Resolution

0.1 mV

Accuracy

+/-  ([% of reading] + [counts]): 0.5% + 2

DC Volts

Range / Resolution

6.000 V / 0.001 V

Range / Resolution

60.00 V / 0.01 V

Range / Resolution

600.00 V / 0.1 V

Accuracy

+/-  ([% of reading] + [counts]): 0.5% + 2

Auto Volts

Range

600.0 V

Resolution

0.1 V

Accuracy

2.0 % + 3 (DC, 45 Hz - 500 Hz)
4.0 % + 3 (500 Hz - 1 kHz)

AC Millivolts1 True-RMS

Range

600.0 mV

Resolution

0.1 mV

Accuracy

1.0 % + 3 (DC, 45 Hz - 500 Hz)
2.0 % + 3 (500 Hz - 1 kHz)

AC Volts1 True-RMS

Range / Resolution

6.000 V / 0.001 V

Range / Resolution

60.00 V / 0.01 V

Range / Resolution

600.0 V / 0.1 V

Accuracy

1.0 % + 3 (DC, 45 Hz - 500 Hz)
2.0 % + 3 (500 Hz - 1 kHz)

Continuity

Range

600 Ω

Resolution

1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.

Range /  Resolution

600.0 Ω / 0.1 Ω

Range / Resolution

6.000 kΩ / 0.001 kΩ

Range / Resolution

60.00 kΩ / 0.01 kΩ

Range / Resolution

600.0 kΩ / 0.1 kΩ

Range / Resolution

6.000 MΩ / 0.001 MΩ

Accuracy

0.9 % + 1

Range / Resolution

40.00 MΩ / 0.01 MΩ

Accuracy

1.5 % + 2

Diode Test

Range / Resolution

 2.000 V / 0.001 V

Accuracy

 0.9% + 2

Capacitance

Range / Resolution

1000 nF / 1 nF

Range / Resolution

10.00 μF / 0.01 μF

Range / Resolution

100.0 μF / 0.1 μF

Range / Resolution

9999 μF / 1 μF

Range / Resolution

100 μF to 1000 μF

Accuracy

1.9% + 2

Range / Resolution

> 1000 μF

Accuracy

5% + 20%

LoZ Capacitance

Range

1 nF - 500 μF

Accuracy

10% + 2 typical

Temperature2 (Type-K Thermocouple)

Range / Resolution

-40°C - 400°C / 0.1°C

Accuracy

1% + 102

Range / Resolution

-40°F - 752°F / 0.2°F

Accuracy

1% + 182

AC μA True-RMS (45 Hz - 500 Hz)

Range / Resolution

600.0 μA / 0.1 μA

Accuracy

1.0% + 2

DC μA

Range / Resolution

600.0 μA / 0.1 μA

Accuracy

1.0% + 2

Hz (V or A input)2

Range / Resolution

99.99 Hz / 0.01 Hz

Range / Resolution

999.99 Hz / 0.1 Hz

Range / Resolution

9.999 Hz / 0.001 Hz

Range / Resolution

50.00 Hz / 0.01 Hz

Accuracy

0.1% + 2

Notes:
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% - 100% of range. Auto-V/LoZ is specified from 0.0 V
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz - 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz - 5 kHz for AC current.
4. Temperature Range / Resolution: -40°F - 752°F / 0.2°F

 

Mechanical & General Specifications

Size

167 mm x 84 mm x 46 mm (6.57 in x 3.31 in x 1.82)

Weight

550 g

Warranty

3 years

 

 

 

Fluke 62 MAX+ Infrared Thermometer

Specifications

Temperature Range

-30°C - 650°C (-22°F - 1202°F)

Accuracy

+/- 1.0°C or +/- 1.0% of reading, whichever is greater
-10°C to 0°C: +/- 2.0
-30°C to -10°C: +/- 3.0

Response Time (95%)

Fluke 62 MAX+

< 300 ms (95% of reading)

Spectral Response

8 µs - 14 µs

Emissivity

0.10 - 1.00

Optical Resolution

12:1 (calculated at 90% energy)

Display Resolution

0.1°C (0.2°F)

Repeatability of Readings

+/- 0.5% of reading or < +/- 0.5°C (1°F), whichever is greater

Power

AA battery

Battery Life

8 h with laser and bACklight on

Weight

255 g (8.99 oz)

Size

175 mm x 85 mm x 75 mm (6.88 in x 3.34 in x 2.95 in)

Temperature

Operating

0°C - 50°C (32°F - 122°F)

Storage

-20°C - 60°C (-4°F - 140°F), (without battery)

Operating Humidity

10% - 90% RH, Non-condensing at 30°C (86°F)

Altitude

Operating

2,000 m above mean sea level

Storage

12,000 m above mean sea level

IP Rating

IP 54 per IEC 60529

Drop Test

3 m

Vibration and Shock

IEC 68-2-6 2.5 g, 10 Hz - 200 Hz, IEC 68-2-27, 50 g, 11 ms

EMC

EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance

EN/IEC 61010-1: 2001

Laser Safety

FDA and EN 60825-1 Class II