Fluke

1587 KIT / 62 MAX+ FC Electrical Troubleshooting Kit

Maintain the uptime of electrical equipment with this troubleshooting and preventative maintenance kit, including a 2-in-1 Insulation DMM, Current Clamp and IR Thermometer


$1,370.00 CAD
Normally ships in 3-4 Weeks

 
  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The products in this kit have been specifically selected for both troubleshooting and preventative maintenance applications.  This kit includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 62 Max+ Infrared Thermometer.

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app including:
1.  Pi/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
2. Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
3.Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
4. Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect Assets

The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

The Fluke 62 MAX+ infrared thermometer is everything you'd want in your toolbox. Small in size, extremely accurate and yet easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3 m drop.

Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 62Max+ Infrared Thermometer
• With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
• Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit
• The Fluke 62 MAX+ Infrared Thermometer measure -30°C to 650°C (-22°F to 1202°F), is extremely accurate, and has an IP54 rating for water resistance and dust proof

The Fluke 1587 FC 2-in-1 Insulation DMM
• Pl/DAR measurements with TrendIt™ graphs
• Memory storage through Fluke Connect Measurements app
• Temperature Compensation through Fluke Connect Measurements app
• VFD low-pass filter for accurate motor drive measurements
• Auto-discharge of capacitive voltage
• Insulation test smoothing reading
• Features include Min/Max, AC/DC voltage, DC millivolts, AC/DC milliamps
• Measures resistance (0.1 Ω - 50 MΩ) and continuity,  frequency, capacitance, diode test, and temperature
• Auto power off
• Remote probe, test leads, alligator clips, K-type thermocouple, and hard case included
• 3 year warranty

Fluke i400 AC Current Clamp
• Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
• 1 mA/Amp output guarantees easy reading CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
• Specially designed to offer maximum utility in a very compact shape
• Maximum conductor: Ø 32 mm
• 1 year warranty

Fluke 62 MAX+ Infrared Thermometer
• Temperature range -30°C to 650°C (-22°F - 1202°F)
• Accuracy +/- 1.0°C or +/- 1.0% of reading, whichever is greater
• -10°C to 0°C: +/- 2.0
• -30°C to -10°C: +/- 3.0
• Response time (95%) Fluke 62 MAX+ < 300 ms (95% of reading)
• Spectral response 8 to 14 microns
• Emissivity 0.10 - 1.00
• Optical resolution 12:1 (calculated at 90% energy)
• Display resolution 0.1°C (0.2°F)
• Repeatability of readings +/- 0.5% of
• Reading or < +/- 0.5°C (1°F), whichever is greater
• Power AA battery
• Battery life 8 hours with laser and backlight on

Fluke 1587 FC Insulation Multimeter

Electrical Specifications

AC Voltage Measurement

Range

600.0 mV

Resolution

0.1 mV

Accuracy 50 Hz - 60 Hz +/- (% of RDG + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 5000 Hz +/- (% of RDG + Counts)

+/- (2% + 3)

6.000 V

Resolution

0.001 V

Accuracy 50 Hz - 60 Hz +/- (% of RDG + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 5000 Hz +/- (% of RDG + Counts)

+/- (2% + 3)

60.00 V

Resolution

0.01 V

Accuracy 50 Hz - 60 Hz +/- (% of RDG + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 5000 Hz +/- (% of RDG + Counts)

+/- (2% + 3)

600.0 V

Resolution

0.1 V

Accuracy 50 Hz - 60 Hz +/- (% of RDG + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 5000 Hz +/- (% of RDG + Counts)

+/- (2% + 3)¹

1000 V

Resolution

1 V

Accuracy 50 Hz - 60 Hz +/- (% of RDG + Counts)

+/- (2% + 3)

Accuracy 60 Hz - 5000 Hz +/- (% of RDG + Counts)

+/- (2% + 3)¹

¹ 1 kHz bandwidth

Low-Pass Filter Voltage 

Range

600.0 mV

Resolution

0.1 mV

Accuracy 50 Hz - 60 Hz +/- (% of Rdg + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 400 Hz +/- (% of Rdg + Counts)

+ (2% + 3), - (6% - 3)

6.000 V

Resolution

0.001 V

Accuracy 50 Hz - 60 Hz +/- (% of Rdg + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 400 Hz +/- (% of Rdg + Counts)

+ (2% + 3), - (6% - 3)

60.00 V

Resolution

0.01 V

Accuracy 50 Hz - 60 Hz +/-(% of Rdg + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 400 Hz +/- (% of Rdg + Counts)

+ (2% + 3), - (6% - 3)

600.0 V

Resolution

0.1 V

Accuracy 50 Hz - 60 Hz +/- (% of Rdg + Counts)

+/- (1% + 3)

Accuracy 60 Hz - 400 Hz +/- (% of Rdg + Counts)

+ (2% + 3), - (6% - 3)

1000 V

Resolution

1 V

Accuracy 50 Hz - 60 Hz +/- (% of Rdg + Counts)

+/- (2% + 3)

Accuracy 60 Hz - 400 Hz +/- (% of Rdg + Counts)

+ (2% + 3), - (6% - 3)

DC Voltage Measurement

Range

Resolution

Accuracy +/- (% of RDG + Counts)

6.000 V DC

0.001 V

+/- (0.09% + 2)

60.00 V DC

0.01 V

+/- (0.09% + 2)

600.0 V DC

0.1 V

+/- (0.09% + 2)

1000 V DC

1 V

+/- (0.09% + 2)

Input Impedance 

10 MΩ (nominal), <100 pF

Normal Mode Rejection Ratio 

>60 dB @ 50 Hz or 60 Hz

Common Mode Rejection Ratio 

>120 dB @ DC, 50 Hz or 60 Hz (1 k unbalance)

Accuracies apply to +/- 100% of range

DC Millivolts Measurement

Range

Resolution

Accuracy +/- (% of RDG + Counts)

600.0 mVDC

0.1 mV

+/- (0.1% + 1)

DC and AC Current Measurement

AC 45 Hz - 1000 Hz

Range

400 mA

Resolution

0.1 mA

Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 2)¹

Burden Voltage (Typical)

2 mV/mA

Range

60 mA 

Resolution

0.01 mA 

Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 2)¹

Burden Voltage (Typical)

2 mV/mA

DC

Range

400 mA

Resolution

0.1 mA

Accuracy +/- (% of RDG + Counts)

+/- (0.2% + 2)

Burden Voltage (Typical)

2 mV/mA

Range

60 mA

Resolution

0.01 mA

Accuracy +/- (% of RDG + Counts)

+/- (0.2% + 2)

Burden Voltage (Typical)

2 mV/mA

Overload

600 mA for 2 min maximum

Fuse Protection for mA Input

0.44 mA, 1000 V, IR 10 kA

AC Conversion

Inputs are AC-coupled and calibrated to the RMS value of sine wave input

Conversions are True-RMS responding and specified from 5% - 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤ 1.5 at 600 mA. For non-sinusoidal waveforms add + (2% reading + 2% FS) typical, for a crest factor up to 3.

¹ 1 kHz bandwidth

Ohms Measurement

Range

Resolution

Accuracy + (% of RDG + Counts)¹

600.0 Ω

0.1 Ω

+/- (0.9% + 2)

6.000 kΩ

0.001 kΩ

+/- (0.9% + 2)

60.00 kΩ

0.01 kΩ

+/- (0.9% + 2)

600.0 kΩ

0.1 KΩ

+/- (0.9% + 2)

6.000 MΩ

0.001 MΩ

+/- (0.9% + 2)

50.0 MΩ ²

0.01 MΩ

+/- (1.5% + 3)

Overload Protection 

1000 Vrms or DC

Open Circuit Test Voltage 

< 8.0 V DC

Short Circuit Current 

< 1.1 mA

¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity

Diode Test

Diode test indication

Display voltage drop: 0.6 V at 1.0 mA nominal test current:

Accuracy

+/- (2% + 3)

Continuity Test

Continuity Indication

Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω

Open Circuit Voltage

< 8.0 V

Short Circuit Current

1.0 mA typical

Overload Protection

1000 Vrms

Response Time

> 1 m s

Frequency Measurement

Range

Resolution

Accuracy +/- (% of RDG + Counts)

99.99 Hz 

0.01 Hz 

+/- (0.1% + 1)

999.9 Hz 

0.1 Hz 

+/- (0.1% + 1)

9.999 kHz 

0.001 kHz 

+/- (0.1% + 1)

99.99 kHz 

0.01 kHz 

+/- (0.1% + 1)

Frequency Counter Sensitivity

600.0 mV AC

V AC Sensitivity (RMS Sine Wave)¹  5 Hz - 20 kHz 

100.0 mV 

V AC Sensitivity (RMS Sine Wave)¹  20 kHz - 100 kHz

150.0 mV 

DC Trigger Levels¹ to 20 kHz²

NA

6.0 V 

V AC Sensitivity (RMS Sine Wave)¹  5 Hz - 20 kHz 

1.0 V 

V AC Sensitivity (RMS Sine Wave)¹  20 kHz - 100 kHz

1.5 V 

DC Trigger Levels¹ to 20 kHz²

-400.0 mV and 2.5 V

60.0 V 

V AC Sensitivity (RMS Sine Wave)¹  5 Hz - 20 kHz 

10.0 V 

V AC Sensitivity (RMS Sine Wave)¹  20 kHz - 100 kHz

36.0 V 

DC Trigger Levels¹ to 20 kHz²

1.2 V and 4.0 V

600.0 V 

V AC Sensitivity (RMS Sine Wave)¹  5 Hz - 20 kHz 

100.0 V 

V AC Sensitivity (RMS Sine Wave)¹  20 kHz - 100 kHz

-

DC Trigger Levels¹ to 20 kHz²

12.0 V and 40.0 V

1000.0 V 

V AC Sensitivity (RMS Sine Wave)¹  5 Hz - 20 kHz 

300.0 V 

V AC Sensitivity (RMS Sine Wave)¹  20 kHz - 100 kHz

-

DC Trigger Levels¹ to 20 kHz²

12.0 V and 40.0 V

¹ Maximum input for specified accuracy = 10x range (1000 Vmax). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input

Capacitance

Range 

Resolution 

Accuracy +/- (% of RDG + Counts)

1000 nF 

1 nF

+/- (1.2% + 2)

10.00 μF 

0.01 μF

+/- (1.2% + 2)

100.0 μF 

0.1 μF

+/- (1.2% +/- 90 counts)

9999 μF 

1 μF

+/- (1.2% +/- 90 counts)

Temperature Measurement

Range 

Resolution 

Accuracy +/-  (% of RDG + Counts)¹

-40° C - 537° C 

0.1°C 

+/- (1% + 10 counts)

-40° F - 998° F 

0.1°F 

+/- (1% + 18 counts)

¹ Accuracies apply following 90 min settling time after a change in the ambient temperature of the instrument

Insulation Specifications

Measurement Range

0.01 MΩ - 2 GΩ

Test Voltages

50 V, 100 V, 250 V, 500 V, 1000 V

Test Voltage Accuracy

+ 20%, - 0%

Short-Circuit Test Current

1 mA nominal

Auto Discharge

Discharge time < 0.5 s for C ≤ 1 μF

Live Circuit Detection

Inhibit test if terminal voltage >  30 V prior to initialization of test

Maximum Capacitive Load

Operable with up to 1 μF load

Output Voltage

50 V (0% - 20%)

Display Range

0.01 - 6.00 MΩ

Resolution

0.01 MΩ

Test Current

1 mA @ 50 kΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (3% + 5 counts)

Display Range

6.0 - 50.0 MΩ

Resolution

0.1 MΩ

Test Current

1 mA @ 50 kΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (3% + 5 counts)

100 V (0% - 20%)

Display Range

0.01 - 6.00 MΩ

Resolution

0.01 MΩ

Test Current

1 mA @ 100 kΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (3% + 5 counts)

Display Range

6.0 - 60.0 MΩ

Resolution

0.1 MΩ

Test Current

1 mA @ 100 kΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (3% + 5 counts)

Display Range

60 - 100 MΩ 

Resolution

1 MΩ

Test Current

1 mA @ 100 kΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (3% + 5 counts)

250 V (0% - 20%)

Display Range

0.1 - 60.0 MΩ 

Resolution

0.1 MΩ

Test Current

1 mA @ 250 kΩ 

Resistance Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 5 counts)

Display Range

60 - 250 MΩ 

Resolution

1 MΩ

Test Current

1 mA @ 250 kΩ 

Resistance Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 5 counts)

500 V (0% - 20%)

Display Range

0.1 - 60.0 MΩ

Resolution

0.1 MΩ

Test Current

1 mA @ 500 kΩ 

Resistance Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 5 counts)

Display Range

60 - 500 MΩ

Resolution

1 MΩ

Test Current

1 mA @ 500 kΩ 

Resistance Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 5 counts)

1000 V (0% - 20%)

Display Range

0.1 - 60.0 MΩ 

Resolution

0.1 MΩ

Test Current

1 mA @ 1 MΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 5 counts)

Display Range

60 - 600 MΩ 

Resolution

1 MΩ

Test Current

1 mA @ 1 MΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (1.5% + 5 counts)

Display Range

0.6 - 2.0 GΩ 

Resolution

100 MΩ 

Test Current

1 mA @ 1 MΩ

Resistance Accuracy +/- (% of RDG + Counts)

+/- (10% + 3 counts)

General Specifications

Maximum Voltage Applied To Any Terminal and Common

1000 V

Temperature

Storage

-40°C - 60°C (-40°F - 140°F)

Operating

-20°C - 55°C (-4°F - 131°F)

Temperature Coefficient

0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)

Relative Humidity

Noncondensing

0% - 95% @ 10°C - 30°C (50°F - 86°F)

0% - 75% @ 30°C - 40°C (86°F - 104°F)

0% - 40% @ 40°C - 55°C (104°F - 131°F)

Vibration

Random, 2 g, 5 Hz - 500 Hz per MIL-PRF-28800F, Class 2 instrument

Radio Frequency Communication

2.4 GHz ISM Band

Radio Frequency Certification

FCC: T68-FBLE, IC: 6627A-FBLE

Electromagnetic Compatibility 

International

IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A

Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.

Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.

Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)

Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

USA (FCC)

47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Enclosure Protection

IEC 60529: IP40 (non-operating)

Safety

IEC 61010-1

Pollution Degree 2

IEC 61010-2-033

CAT IV 600 V / CAT III 1000 V

Batteries 

Four AA batteries (NEDA 15A or IEC LR6)

Battery Life

Meter use 1000 h;

Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 s on and 25 s off

Size (H x W x L)

5.0 cm x 10.0 cm x 20.3 cm (1.97 in x 3.94 in x 8.00 in)

Weight

550 g (1.2 lb)

Altitude

Operating

2000 m

Storage

12,000 m

Over-Range Capability

110% of range except for capacitance, which is 100%

Frequency Overload Protection

< 107 V Hz

Fuse Protection for mA Input

0.44A, 1000 V, IR 10 kA

             

 

 

 

Fluke i400 AC Current Clamp

 

Specifications

Nominal Current Range

400  A

Continuous Current Range

1 A - 400 A

Maximum Non-Destructive Current

1000 A

Lowest Measurable Current

1 A

Basic Accuracy

2% + 0.06 A

(45 - 400 Hz)

(% reading + floorspec)

Useable Frequency

5 Hz - 20 kHz

Output Level(s)

1 mA/A

Safety Specifications

Safety

CAT IV 600 V, CAT III, 1000 V

Maximum voltage

1000 V ACrms from earth to ground, in compliance with EN61010

Mechanical and General Specifications

Warranty

1 year

Maximum Conductor Diameter

32 mm (1.25 in)

Maximum Conductor Size (Busbar)

750 MCM

Output Cable Length

1.5 m (59 in)

Shrouded Banana Plugs

Yes

 

 

 

 

Fluke 62 MAX, 62 MAX Infrared Thermometers 

Specifications

Temperature Range

-30°C - 650°C (-22°F - 1202°F)

Accuracy

+/- 1.0°C or +/- 1.0% of reading, whichever is greater

-10°C to 0°C: +/- 2.0

-30°C to -10°C: +/- 3.0

Response Time (95%)

< 300 ms (95% of reading)

Spectral Response

8 to 14 µs

Emissivity

0.10 - 1.00

Optical Resolution

12:1 (calculated at 90% energy)

Display Resolution

0.1°C (0.2°F)

Repeatability of Readings

+/- 0.5% of reading or < +/- 0.5°C (1°F), whichever is greater

Power

AA battery

Battery Life

8 h with laser and backlight on

Physical Specifications

Weight

255 g (8.99 oz)

Size

175 mm x 85 mm x 75 mm (6.88 in x 3.34 in x 2.95 in)

Temperature

Operating

0°C - 50°C (32°F - 122°F)

Storage

-20 °C to 60 °C (-4 °F to 140 °F), (without battery)

Operating Humidity

10% - 90% RH non-condensing at 30°C (86°F)

Altitude

Operating

2000 m above mean sea level.

Storage

12,000 m above mean sea level

IP Rating

IP 54 per IEC 60529

Drop Test

3 m

Vibration and Shock

IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

EMC

EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance

EN/IEC 61010-1: 2001

Laser Safety

FDA and EN 60825-1 Class II

         
 

 

Item
Description
Availability
Price
Adapts Type-K thermocouple mini-connector to dual shrouded banana plug inputs
Normally ships in 4-6 Weeks
$42.00 CAD
Designed to reliably measure temperatures on flat or slightly convex surface
Normally ships in 4-6 Weeks
$455.00 CAD
Type K thermocouple with exposed junction for flat or slightly convex surfaces such as plate and rollers
Normally ships in 4-6 Weeks
$222.00 CAD
Type K thermocouple for fast temperature and superheat measurements of pipe surfaces
Normally ships in 4-6 Weeks
$249.00 CAD
The hard case that fits all Fluke industrial test tools
Normally ships in 4-6 Weeks
$113.00 CAD
Protect your meter and conveniently carry it from one job to the next with this handy carrying case
Normally ships in 4-6 Weeks
$56.00 CAD
Rugged ballistic cloth with heavy duty hardware, including a steel reinforced frame
Normally ships in 4-6 Weeks
$140.00 CAD
Unbreakable, watertight, airtight, dustproof, chemical resistant and corrosion proof case that floats in salt water
Normally ships in 4-6 Weeks
$281.00 CAD
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters
Normally ships in 4-6 Weeks
$63.00 CAD
This test lead set with test probes works in multiple electrical applications while the SureGrip feature is designed to do your work with comfort
Normally ships in 4-6 Weeks
$112.00 CAD
Digital multimeter test leads (red, black) with safety shrouded, standard diameter banana plugs
Normally ships in 4-6 Weeks
$49.00 CAD
Small, rugged light easily attaches to any Fluke test probe
Normally ships in 4-6 Weeks
$43.00 CAD
L200 probe light and TP280 test probe extenders illuminate contact area while keeping hands away from live circuits
Normally ships in 4-6 Weeks
$63.00 CAD
SureGrip alligator clips
Normally ships in 4-6 Weeks
$36.00 CAD
Includes all the SureGrip leads and probes in a handy six-pocket, roll-up pouch, along with TL224 test leads
Normally ships in 4-6 Weeks
$223.00 CAD
Interactive battery analyzer test probe set for the Fluke BT510 Battery Analyzer
Normally ships in 4-6 Weeks
$1,096.00 CAD
Highly reliable and accurate current clamp that measures 1 A to 1000 A without breaking the circuit
Normally ships in 4-6 Weeks
Starting At
$582.00 CAD
Configure
Extend the current ranges of multimeters with a single range 200 A clamp-on AC Current Clamp with safety shrouded banana plugs
Normally ships in 4-6 Weeks
$219.00 CAD
Extend the use of digital multimeters
Normally ships in 1-2 Weeks
$219.00 CAD