Fluke

3000 FC HVAC System

Work on electrical panels faster, safer, and easier with remote current and temeprature modules


$863.00 CAD
Normally ships in 3-4 Weeks

 
  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The Fluke 3000FC HVAC system provides measurement of all common electrical parameters.  This kit consists of the Fluke 3000FC Series Wireless Multimeter, the Fluke a3000FC Wireless AC Current Clamp Module, and the Fluke T3000 FC Wireless K-Type Temperature Module

Connect the A3000FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 m away on the Fluke 3000FC Series Wireless Digital Multimeter. Plus, you can connect the T3000FC Wireless K-Type wireless temperature module and view remote temperature measurements. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect® modules as a system for multiple measurements.

Now you can take readings on moving machinery, with only the measurement module in harm’s way.

• Provides measurement of all common electrical parameters

3000FC Series Wireless Multimeter:
• AC and DC voltage measurements to 1000 V
• AC and DC current with 0.01 mA resolution
• Continuity, resistance, diode test, capacitance and frequency measurements
• MIN/MAX recording
• CAT III 1000 V, Cat IV 600 V; IP54

a3000 FC Wireless AC Current Clamp Module:
• True-RMS AC clamp meter
• Measure up to 400 A AC
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings
• Inrush function

T3000FC Wireless K-Type Temperature Module:
• Use as a standalone meter or as part of the system
• Logging function for recording and saving up to 65,000 readings

Fluke 3000FCSeries Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C - 28°C, with relative humidity at 0% - 90%. Accuracy specifications take the form of +/- ([ % of Reading ] + [ Number of least significant digits ])

 

Detailed Specifications

AC Voltage

Range1

Resolution

Accuracy2, 3, 4

45 Hz - 500 Hz

500 Hz - 1 kHz

600.0 mV

0.1 mV

1.0% + 3

2.0% + 3

6.000 V

0.001 V

60.00 V

0.01 V

600.0 V

0.1 V

1000 V

1 V

 

1 All AC voltage ranges are specified from 1% of range to 100% of range.
2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add +/- (2% of reading + 2% full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.

 

DC Voltage, Continuity, Resistance, Diode Test and Capacitance

Function

Range

Resolution

Accuracy

mV

600.0 mV

0.1 mV

0.09% + 2

V

6.000 V

0.001 V

0.09% + 2

60.00 V

0.01 V

600.0 V

0.1 V

1000 V

1 V

0.15% + 2

600 Ω

1 Ω

Meter beeps at < 25 Ω; beeper detects opens or shorts of 250 μs or longer.

600.0 Ω

0.1 Ω

0.5% + 2

6.000 kΩ

0.001 kΩ

0.5% + 1

60.00 kΩ

0.01 kΩ

60.00 kΩ

0.1 kΩ

600.0 kΩ

0.001 MΩ

50.00 MΩ

0.01 MΩ

1.5% + 3

Diode Test

2.000 V

0.001 V

1% + 2

µF

1000 nF

1 nF

1.2% + 2

10.00 μF

0.01 μF

100.0 μF

0.1 μF

9999 μF1

1 μF

10% typical

 

1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

 

AC and DC Current

Function

Range 1

Resolution

Accuracy

mA AC
(45 Hz - 1 kHz)

60.00 mA

0.01 mA

1.5 % + 3

400.0 mA 3

0.1 mA

mA DC 2

60.00 mA

0.01 mA

0.5 % + 3

400.0 mA 3

0.1 mA

 

1 All AC current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.

 

Frequency

Range

Resolution

Accuracy 1

 

99.99 Hz

0.01 Hz

0.1 % + 1

 

999.9 Hz

0.1 Hz

9.999 kHz

0.001 kHz

99.99 kHz

0.01 kHz

 

1 Frequency is specified up to 99.99 kHz in V and up to 10 kHz in A.

 

mA Function

Overload Protection

Fused, 44/100 A, 1000 V FAST Fuse

Overload

600 mA overload for 2 min maximum, 10 min rest minimum

 

MIN/MAX Recording Accuracy

DC Functions

The specified accuracy of the measurement function +/- 12 counts for changes > 350 mS in duration.

AC Functions

The specified accuracy of the measurement function +/- 40 counts for changes > 900 mS in duration.

 

General Specifications

Maximum Voltage Between Any Terminal and Earth Ground

1000 V DC or AC RMS

Ω Fuse Protection From A Inputs

0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only

Display (LCD)

Update rate: 4/s
V, A, Ω: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts

Battery Type

Three AA Alkaline batteries, NEDA 15A IEC LR6

Battery Life

250 h, minimum

RF Communications

2.4 GHz ISM Band

RF Communication Range

Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m

Temperature

Operating

-10°C - 50°C

Storage

-40°C - 60°C

Temperature Coefficient

0.1 X (specified accuracy) /°C (<18°C or >28°C)

Relative Humidity

0% - 90% (0°C - 35°C)
0% - 75% (35°C - 40°C)
0% - 45% (40°C - 50°C)

Altitude

Operating

2,000 m

Storage

12,000 m

Electromagnetic Compatibility
(EMI, RFI, EMC, RF)

EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE

Safety Compliance

ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010

Certifications

CSA, FCC, CE

Ingress Protection (IP) Rating

IP54

Pollution Degree

2

Size (H x W x L)

4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)

Weight

340 g (12 oz)

Warranty

3  years

       

Note: Not compatible with Fluke CNX test tools

 

 

 

Fluke A3000FC Wireless AC Current Clamp Module 

Specifications

Range

0.5 A - 400.0 A

Resolution

0.1 A

Accuracy

400.0 A: 2 % +/- 5 digits (10 Hz - 100 Hz)

2.5% +/- 5 digits (100 Hz - 500 Hz)

Inrush

Max displayed reading: 999.9A

Crest Factor (50 / 60 Hz)

3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2% for C.F. > 2

LCD With Backlight

3 1/2 digits

Log Rate / Interval

1 s minimum/adjustable by PC

Battery Type

2 AA, NEDA 15 A, IEC LR6

Battery Life

400 hs

Memory

Record up to 65,000 readings

RF Communications

2.4 GHz ISM Band

RF Communication Range

Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m

Operating Temperature

-10°C- 50°C

Storage Temperature

-40°C - 60°C

Temperature Coefficient

Add 0.1 x (specified accuracy)/°C (< 18°C or > 28°C)

Operating Humidity

90% at 35°C

75% at 40°C

45% at 50°C

Altitude

Operating

2,000 m

Storage

12,000 m

EMC

EN 61326-1:2006

Safety Compliance

IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2

Safety Rating

CAT III 600 V

Certifications

CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE

Ingress Protection (IP) Rating

IP30

Pollution Degree

2

Jaw Opening

34 mm (1.33 in)

Size (H x W x D)

20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)

Weight

0.22 kg (8 oz)

Warranty

3 years

 

Note: Not compatible with Fluke CNX test tools

 

 

 

Fluke T3000FC Wireless K-Type Temperature Module

General Specifications

Range K-Type

-200°C - 1372°C

Resolution

0.1°C

Accuracy

+/- (0.5% + 0.3°C) counts

Input Terminals

K-type mini

LCD With Backlight

3 1/2 digits

Log Rate / Interval

1 s minimum/adjustable by PC

Battery Type

2 AA, NEDA 15 A, IEC LR6

Battery Life

400 h

Memory

Record up to 65,000 readings

RF Communications

2.4 GHz ISM Band

RF Communication Range

Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m

Operating Temperature

-10°C - 50°C

Storage Temperature

-40°C - 60°C

Temperature Coefficient

0.01% of reading + 0.03°C per °C

Temperature Scale

ITS-90

Operating Humidity

90% at 35°C

75% at 40°C

45% at 50°C

Altitude

Operating

2,000 m

Storage

12,000 m

EMC

EN 61326-1:2006

Safety Compliance

IEC 61010-1, CAT I, 3rd edition Pollution Degree 2

Certifications

CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE

Ingress Protection (IP) Rating

IP42

Pollution Degree

2

Size (H x W x D)

16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)

Weight

0.22 kg (8 oz)

Warranty

3 years

 

Note: Not compatible with Fluke CNX test tools

 

Item
Description
Availability
Price
TL175 TwistGuard Test Leads
Quality test leads with adjustable length test tips for use in different measurement environments and increased safety
Normally ships in 4-6 Weeks
Starting At
$45.00 CAD
Configure
PC3000FC Wireless PC Adapter
Adapter and software wirelessly collect up to 65,000 sets of time stamped Min/Max/Avg readings from FC remote modules
Normally ships in 4-6 Weeks
$137.00 CAD