Fluke

414D / 62 MAX+ Laser Distance Meter / Infrared Thermomet...

This kit has everything you need to configure layout and troubleshoot electrical/HVAC problems quickly


$356.00 CAD
Normally ships in 4-6 Weeks

 
  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/HVAC problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.

Kit includes the 414D Laser Distance Meter and the 62 MAX+ Infrared Thermometer.

414D Laser Distance Meter:
• The most advanced laser technology for distance measurement
• Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
• Quick calculation of area (ft2/m2) and volume
• Pythagoras function indirectly measures height via two other measurements
• Stores up to five measurement results
• Battery life of 3000 measurements with automatic shut-off feature

62 MAX+ Infrared Thermometer:
• Dust and water-resistant, and IP54 rated
• Rugged and can withstand a 3 m (9.8 ft) drop (drop tested)
• Ergonomically designed for a more natural hand fit
• Distance to spot of 12:1
• Dual lasers identifies area to be measure
• Large, backlit display makes data easier to read, even in dark areas

Fluke 414D Laser Distance Meter  

Distance Measurement

Typical Measuring Tolerance1

+/- 2.0 mm3

Maximum Measuring Tolerance2

+/- 3.0 mm3

Range at Leica target plate GZM26

50 m (165 ft)

Typical Range1

40 m (130 ft)

Range at Unfavorable Condition4

35 m (115 ft)

Smallest Unit Displayed

1 mm (1/16 in)

Laser Point at Distances

6 mm / 30 mm / 60 mm (10 m / 50 m / 100 m)

Tilt Measurement

Measuring Tolerance to Laser Beam5

No

Measuring Tolerance to Housing5

No

Range

No

General

Laser Class

2

Laser Type

635 nm, < 1 mW

Protection Class

IP40

Automatic Laser Off

after 90 s

Automatic Power Off

after 180 s

Battery Type

Two (2) AAA 1.5 V NEDA 24 A/IEC LR03

Battery Life

Up to 3,000 measurements

Size (L X W X D)

116 mm x 53 mm x 33 mm

Weight (with Batteries)

113 g

Temperature Range

Storage

-25°C - 70°C (-13°F - 158°F)

Operation

0°C - 40°C (32°F - 104°F)

Calibration Cycle

Not applicable

Maximum Altitude

3000 m

Maximum Relative Humidity

85% at -7°C - 50°C (20°F - 120°F)

Safety

IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)

EMC

EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010

1Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.
2Applies for 10 to 500 % target reflectivity, high background illumination, -10°C - 50°C.
3Tolerances apply from 0.05 m - 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m - 30 m and to 0.15 mm/m for distances above 30 m.
4Applies for 100% target reflectivity, background illumination between 10'000 lux - 30'000 lux.
5After user calibration. Additional angle related deviation of +/- 0.01° per ° up to +/- 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by +/- 0.1°.

 

Fluke 62 MAX+ Infrared Thermometer

Specifications

Temperature Range

-30°C - 650°C (-22°F - 1202°F)

Accuracy

+/- 1.0°C or +/- 1.0% of reading, whichever is greater

-10°C to 0°C:

+/- 2.0

-30°C to -10 °C

+/- 3.0

Response Time (95%)

62 MAX+

< 300 ms (95% of reading)

Spectral Response

8 µs - 14 µs

Emissivity

0.10 - 1.00

Optical Resolution

12:1 (calculated at 90% energy)

Display Resolution

0.1°C (0.2°F)

Repeatability of Readings

+/- 0.5% of reading or < +/- 0.5°C (1°F), whichever is greater

Power

AA battery

Battery Life

8 h with laser and backlight on

Weight

255 g (8.99 oz)

Size

175 mm x 85 mm x 75 mm (6.88 in x 3.34 in x 2.95 in)

Temperature

Operating

0°C - 50°C (32°F - 122°F)

Storage

-20°C - 60°C (-4°F - 140°F), (without battery)

Operating Humidity

10% - 90% RH non-condensing at 30°C (86°F)

Altitude

Operating

2000 m above mean sea level

Storage

12,000 m above mean sea level

IP Rating

IP 54 per IEC 60529

Drop Test

3 m

Vibration and Shock

IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

EMC

EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance

 EN/IEC 61010-1: 2001

Laser Safety

FDA and EN 60825-1 Class II

         

Item
Description
Availability
Price
Zippered carrying case with inside pocket belt loop and inside meter strap
Normally ships in 4-6 Weeks
$56.00 CAD
Zippered carrying case with a divisible main compartment, detachable side pouches, and a shoulder strap
Normally ships in 4-6 Weeks
$247.00 CAD
Rugged fabric holster includes flap for lead storage and built-in belt loop
Normally ships in 4-6 Weeks
$49.00 CAD
Rugged ballistic cloth with heavy duty hardware, including a steel reinforced frame
Normally ships in 4-6 Weeks
$140.00 CAD