5627A Precision Thermometer, RTD Temperature Probe

Manufactured using a coil suspension element design for increased shock and vibration resistance

Starting At
$1,269.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

When buying a PRT or RTD temperature probe, performance isn’t the only criterion you need to look at. The real issues are price-to-accuracy and price-to-durability ratios.

5627A probes have a temperature range up to 420°C and accuracy as good as +/- 0.025°C. They come in three different lengths.  Each precision thermometer is shipped with its ITS-90 coefficients and a calibration table in 1°C increments.

One of the best features of this sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully. Why use a precision thermometer or RTD temperature probe that’s less accurate than your meter?

The 5627A is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order.)

Six- and nine-inch 5627A precision thermometers are calibrated at –196°C, –38°C, 0°C, 200°C, and 300°C. For 12 in versions of these precision thermometers, the point at 300°C is replaced by a calibration point at 420°C.

Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer.

This RTD temperature probe is an excellent value for a precision thermometer. It has the price-to-accuracy and price-to-durability ratios you should demand in all of the precision thermometers you buy!

 • Vibration and shock resistant
 • NVLAP-accredited calibration included

Resistance Nominal 100 Ω
Temperature Coefficient 0.00385 Ω/Ω/C nominal
Temperature Range −200C to 420C (5627A-6 and 5627A-9 to 300C; transition and cable temperature: 0C to 150C)
Drift Rate (k = 2) +/- 0.04C at 0C after 100 hrs at 420C
Sheath Material 316 Stainless Steel
Leads PTFE-insulated, nickel-plated stranded copper, 22 AWG
Termination Specify. See Ordering Information.
Time Constant Four seconds maximum for 63.2% response to step change in water moving at 3 fps.
Bending Radius Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.)
Calibration Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1C increments from -196C - 500C (to 300C for 5627A-6 and 5627A-9).
ITS-90 coefficients included.
Immersion At least 100 mm (4 in) recommended
Calibrated Accuracy (k=2) +/- 0.026C at -196C
+/- 0.046C at 0C
+/- 0.077C at 200C
+/- 0.124C at 420C
Size 5627A-12: 305 mm x 6.35 mm (12 in x 1/4 in)
5627A-9: 229 mm x 4.7 mm (9 in x 3/16 in)
5627A-6: 152 mm x 4.7 mm (6 in x 3/16 in)
Includes calibration uncertainty and 100 hr drift.
Item
Description
Availability
Price
Plastic probe carrying case for probes up to 228 mm (9 in) in length
Normally ships in 1-2 Weeks
$205.00 CAD
Plastic probe carrying case for probes 635 mm (25 in) in length
Normally ships in 1-2 Weeks
$301.00 CAD