Dwyer

629C Wet/Wet Differential Pressure Transmitter

Monitors differential pressure of air and compatible gases and liquids with 0.5% accuracy, dual pressure sensors, zero adjust button

Starting At
$492.00 CAD
Normally ships in 3-4 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The Series 629C Wet/Wet Differential Pressure Transmitter monitors differential pressure of air and compatible gases and liquids with 0.5% accuracy. The design employs dual pressure sensors converting pressure changes into a standard 4 - 20 mA output signal or field selectable voltage. Small internal volume and minimal moving parts result in exceptional response and reliability. The terminal block, as well as a zero adjustment button, are easily accessed under the top cover. The Series 629C Differential Pressure Transmitter is designed to meet NEMA 4X (IP66) construction.

• Versatile, high accuracy device for liquid or gas supports designs requiring more precise measurements in support of application
• Minimum components provide excellent response and reliability
• Zero control reduces installation and service time
• Terminal block reduces wiring difficulties saving installation time
• Optional LCD indicator provides local status to identify operational conditions
• Optional 3-way valve manifold supports higher line pressures or simplifies removal of transmitter without interrupting process


 

Service Compatible gases and liquids
Wetted Materials Without valve: 316, 316L SS.
Additional wetted parts with valve option: Buna-N, silicone grease, PTFE, brass 360, copper, and reinforced copolymer
Accuracy 0.5% FS (includes linearity, hysteresis & repeatability)
Stability 1% FS/year
Temperature Limits 0F - 200F (-18C - 93C)
Compensated Temperature Limits 0F - 175F (-18C - 79C)
Pressure Limits See Chart on Catalog
Thermal Effect Avg 0.04%/F (0.072%/C) (includes zero and span)
Power Requirements 2-wire: 10 - 35 VDC;
3-wire: 13 - 35 VDC or isolated 16 - 33 VAC (reverse polarity protected)
Output Signal 2-wire: 4 - 20 mA;
3-wire: Field selectable 0 - 5, 1 - 5, 0 - 10, or 2 - 10 VDC
Zero and Units Push buttons inside conduit enclosure
Response Time 400 ms
Loop Resistance Current Output: 0 Ω - 1250 Ω (max),
Rmax = 50 (Vps-10);
Voltage Output: Minimum load resistance = 5 kΩ
Current Consumption 28 mA (max)
Electrical Connections Removable terminal block; 1/2 in female NPT conduit
Process Connections 1/4 in female or male NPT
Display Optional 4-1/2 digit LCD field attachable display
Enclosure Rating Designed to meet NEMA 4X (IP66)
Mounting Orientation Not position sensitive
Weight 10.1 oz (286 g)
Agency Approvals CE

• Flow elements
• Heat exchangers
• Filters
• Coils
• Chiller
• Pumps