The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.
Built to highest safety standards
All the inputs in the 87V are updated to the third edition of the EN 61010-1 to CAT III 1000 V and CAT IV 600 V. The meter is designed to withstand spikes of more than 8000 V. You also benefit from an audible Input Alert warning if the test leads are placed in the incorrect input jacks for the measurement being made.
Removable holster with built in test lead and probe storage for convenience
The 87V has a removeable holster that also holds a test probe during testing for easier viewing. Relative mode lets you remove test lead resistance, improving accuracy of low-resistance measurements. To make your life even easier, the 87V fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.
Voltage DC | Maximum voltage: 1000 V Accuracy: ±(0.05% + 1) Maximum resolution: 10 µV |
Voltage AC | Maximum voltage: 1000 V Accuracy:±(0.7% + 2) True RMS AC bandwidth: 20 kHz with low pass filter; 3 dB @ 1 kHz Maximum resolution: 0.1 mV |
Current DC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(0.2% + 2) Maximum resolution: 0.01 µA |
Current AC | Maximum amps: 10 A (20 A for 30 seconds maximum) Amps accuracy: ±(1.0% + 2) True RMS Maximum resolution: 0.1 µA |
Resistance | Maximum resistance: 50 MΩ Accuracy: ±(0.2% + 1) Maximum resolution: 0.1 Ω |
Capacitance | Maximum capacitance: 9,999 µF Accuracy: ±(1% + 2) Maximum resolution: 0.01 nF |
Frequency | Maximum frequency: 200 kHz Accuracy: ±(0.005% + 1) Maximum resolution: 0.01 Hz |
Duty Cycle | Maximum duty cycle: 99.9% Accuracy:±(0.2% per kHz + 0.1%) Maximum resolution:0.1% |
Temperature Measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
80 BK Temperature Probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
Conductance | Maximum conductance: 60.00 nS Accuracy:±(1.0% + 10) Maximum resolution:0.01 nS |
Diode | Range: 3 V Resolution: 1 mV Accuracy: ±(2% + 1) |
Duty Cycle Range | Accuracy: Within ±(0.2% per kHz + 0.1%) |
Operating Temperature | –20 °C to + 55 °C |
Storage Temperature | –40 °C to + 60 °C |
Humidity (Without Condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
Operating Altitude | 2000 m |
Overvoltage Category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
Agency Approvals | CE, CSA, RCM |
Size | 201 x 98 x 52 mm (with holster) |
Weight | 355 g 624 g – with holster |
Display | Digital: 6000 counts updates 4/sec. 19,999 counts in high–resolution mode Analog:32 segments, updates 40/sec Frequency:19,999 counts, updates 3/sec at > 10 Hz |
Warranty | Lifetime |
Battery Life | Alkaline: ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010–1:2001 |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
View All Part Numbers