Provides graphical, tabular, & summary data for analysis, smaller, lighter design & LED status indicators, improved battery life
The new UltraShock contains powerful improvements and an all-in-one functionality, allowing it to replace all current shock models and their capabilities. New refinements also include a smaller, lighter design and LED status indicators.
Additional features include a significantly improved battery life and the use of a USB-C cable, making it easily rechargeable. Each UltraShock purchase contains an AC adapter and USB cable, eliminating the need for an additional interface cable.
The UltraShock is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
• Compact size
• 3-axis shock
• Temperature, humidity, pressure
• Fully configurable measurements
• Long life rechargeable battery
• Large capacity event memory
• Programmable start time
• Real time operation
• CE compliant
• Separate low-g and high-g accelerometers
Memory | 4,000,000 readings (660,000 per channel, all channels in use) |
Reading Rate | 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure & humidity sampled approx. every 2 seconds at intervals shorter than 2 seconds. Otherwise, sampled at the reading rate. |
Battery Life | 90 days typical at 64Hz rate |
Material | Anodized aluminum |
Dimensions | 3.4 in x 1.7 in x 1.3 in (86 mm x 43 mm x 33 mm) |
Operating Environment | -20 °C to +60 °C, 0 %RH to 95 %RH non-condensing |
Required Interface Package | USB (type C cable required); 1MBaud |
Approvals | CE compliant EMC Directive 2014/30/EU RoHS Directive 2011/65/EU IP Rating 64 |
Temperature Sensor | Semiconductor |
Temperature Range | -20 °C to +60 °C |
Temperature Resolution | 0.1 °C |
Temperature Accuracy | ±0.5 °C (+0 °C to +50 °C) |
Humidity Sensor | Capacitive Polymer |
Humidity Range | 0 %RH to 95 %RH |
Humidity Resolution | 0.1 %RH |
Humidity Calibrated Accuracy | ±3 %RH (±2 %RH typical at 25 °C) |
Humidity Specified Accuracy Range | 0 °C to +50 °C; 20 %RH to 80 %RH |
Pressure Sensor | Semiconductor Strain Gage |
Pressure Range | 100 to 1300 mbar |
Pressure Resolution | 0.05 mbar |
Pressure Calibrated Accuracy | ±1.5 mbar at 25 ºC; at 750 mbar |
Shock Accelerometer Type | MEMS Semiconductor |
Shock Acceleration Range (g) | ±15 g/±100 g/±300 g |
Shock Acceleration Resolution (g) | 0.02 g/0.05 g/0.2 g |
Shock Calibrated Accuracy (g) | ±0.3 g/±2.0 g/±6.0 g |
Shock Sampling Rate | 1000 Hz |
Shock Accelerometer Freq. Resp. | >1000 Hz (15 g) >500 Hz (100 g, 300 g) |
Shock Reading Rate | 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure & humidity sampled approx. every 2 seconds at intervals shorter than 2 seconds. Otherwise, sampled at the reading rate. |
• Complete environmental shipment monitoring
• Shipping live cargo
• Aircraft turbulence measurement
• Endurance testing
• Assembly line monitoring
• Brake testing
• Laboratory drop testing
• Machinery monitoring
• Railcar coupling impacts
Madgetech 902121-00 UltraShock Data Logger - Data sheet 1.4 MB |