Fluke Calibration

9100S Handheld Dry-Wells

Smallest, lightest, and most portable dry-wells in the world

Starting At
$3,117.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

Fluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!

Despite its small size and light weight, the 9100S outperforms every dry-well in its class.  It’s simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field. Plug it in, switch it on, set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Fluke Calibration temperature controller, the 9100S has a display resolution of 0.1°, an accuracy of +/- 0.5°C, a stability of +/- 0.1°C, and a stabilization time of just five minutes.

For work in the temperature range of -10°C - 122°C, our Model 9102S dry-well is another first in the industry, featuring stability to +/- 0.05°C. This dry-well is only four inches high and six inches wide, achieves temperatures as low as -10°C, includes a NIST-traceable calibration, and is stable to +/- 0.05°C. The Model 9102S is excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient. It has two ½ in wells so you can use one for a reference thermometer to increase accuracy. The 9102S also has a battery pack option that gives you approximately four hours of field use when AC power is unavailable.

Note: These wells are fixed and not interchangeable.

• Smallest dry-wells in the world
• Ranges from –10°C - 375°C
• Accuracy to +/- 0.25°C, stability of +/- 0.05°C at 0°C
• RS-232 interface with 9930 Interface-it v3.81 software

 

 

9100S

9102S

Range

35°C - 375°C (95°F - 707°F

-10°C - 122°C (14°F - 252°F) at 23°C ambient

Accuracy

+/- 0.25°C at 50°C;

+/- 0.25°C at 100°C;

+/- 0.5°C at 375°C

+/- 0.25°C

Stability

+/- 0.07°C at 50°C;

+/- 0.1°C at 100°C;

+/- 0.3°C at 375°C

+/- 0.05°C

Well-to-Well Uniformity

+/- 0.2°C with sensors of similar size at equal depths within wells

Heating Times

35°C - 375°C: 9.5 min

ambient to 100°C: 10 min

Stabilization

5 min

7 min

Cooling Times

375°C - 100°C: 14 min

ambient to 0°C: 10 min

Well Depth

102 mm (4 in); 1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep

102 mm (4 in)

Removable Inserts

N/A

Available in sizes from 1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included]

Power

115 VAC (+/- 10%), 55-65 Hz, 1.5 A or 230 VAC (+/- 10%), 0.8 A, 45-55 Hz, 175 W

94-234 V ac (± 10 %), 50/60 Hz, 60 W;or 12 VDC
 

Size (H x W x D)

57 mm x 125 mm x 150 mm

(2.25 in x 4.9 in x 6.1 in)

99 mm x 140 mm x 175 mm

(3.9 in x 5.5 in x 6.9 in)

Weight

1 kg (2 lb 3 oz)

1.8 kg (4 lb)

Computer Interface

RS-232 included with free Interface-it software

NIST-Traceable Calibration

Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 375°C

Data at -10°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 122°C

Item
Description
Availability
Price
Inserts for the 9009, 9100S and 9102S dry-wells
Normally ships in 1-2 Weeks
Starting At
$253.00 CAD
Configure
Rugged carrying case for the 9100S handheld dry-well
Normally ships in 1-2 Weeks
$240.00 CAD
Rugged carrying case for the 9102S handheld dry well, 9132 portable infrared calibrator, or 9140 dry-well calibrator
Normally ships in 1-2 Weeks
$337.00 CAD
Interface cable kit used to connect the 754 with dry-wells and micro-baths
Normally ships in 1-2 Weeks
$274.00 CAD