Offers all the most commonly used HVAC digital multimeter features such as temperature, micro amps, and capacitance
Designed primarily for HVAC professionals, the AM-520 autoranging digital multimeter offers all the most commonly used HVAC digital multimeter features such as temperature, micro amps to troubleshoot flame sensors, and capacitance to check motor startup capacitors. With its CAT III safety rating, this high voltage multimeter measures a broad range of electrical parameters. The backlit LCD display makes it easy to read, and it's easy to use with non-contact voltage detection, the “third hand probe holder, and the built-in flashlight.
The AM-520 comes with test leads, K-type thermocouple probe, one (1) 9 V (6F22) battery (installed), user's manual, velcro strap, and a carrying case.
• Measures AC/DC voltage up to 600 V, AC/DC current, resistance, frequency, capacitance and temperature
• CAT III 600 V safety rated
• Non-contact voltage detection enhances safety
• Audible continuity quickly identifies shorts and opens
• Diode test to verify polarity
• Data hold freezes the reading on the display for further analysis
• Min/Max recording records Min/Max measurements over time to show voltage fluctuations
• Relative zero mode displays the difference between the actual reading and a stored reference value and may be used with any function or range
• Combines user friendly features such as, auto power-off to conserve battery life, low battery warning, a “third hand test probe holder, built-in test leads storage, a built-in flashlight, and a Velcro strap to hang the meter
• Auto and manual-ranging delivers maximum flexibility
• Backlit LCD display with analog bar graph makes it easy to view results
AM-520 | BEST ACCURACY | |
AC Voltage | 400 mV, 4.000 V, 40.00 V, | ± (1.0% RDG + 3 LSD) |
DC Voltage | 400 mV, 4.000 V, 40.00 V, | ± (0.8% RDG + 1 LSD) |
AC Current | 400.0 μA, 4000 μA, | ± (1.2% RDG + 3 LSD) |
DC Current | 400.0 μA, 4000 μA, | ± (1.2% RDG + 3 LSD) |
Frequency | 10 Hz - 10 MHz | ± (0.1% RDG + 4 LSD) |
Resistance | 400.0 Ω, | ± (1.0% RDG + 2 LSD) |
Capacitance | 40.00 nF, 400.0 nF, | ± (3.0% rdg + 5 LSD) |
Temperature | -40°F - 1832°F | ± (1.8% RDG + 6°F) @ > 32°F - 212°F |
Number of Temperature Inputs | Single Thermocouple | - |
For more detailed specifications, please download the product datasheet under the “Resources" tab.
AM-500 | AM-510 | AM-520 | AM-530 | AM-560 | AM-570 | |||
Multimeter Type | Auto-Ranging | Com / Res | HVAC | Electrical | Adv. HVAC | Industrial | ||
F | Safety Rating | Safety | CAT III 600V | CAT III 600V | CAT III 600V | CAT III 600V | CAT IV 600V | CAT IV 600V |
Measure Voltage in Noisy Environments | True-RMS | • | • | |||||
Electrical Panels, AC Outlets | AC Voltage (V) | 600 | 600 | 600 | 600 | 1000 | 1000 | |
DC Systems, Auto/Marine Batteries | DC Voltage (V) | 600 | 600 | 600 | 600 | 1000 | 1000 | |
AC Current - Electrical Panels, Appliances | AC Current (A) | 10 | 10 | 10 | 10 | 10 | 10 | |
DC Current-Electronics, DC Motors | DC Current (A) | 10 | 10 | 10 | 10 | 10 | 10 | |
Specified Resistance and Continuity | Resistance (MΩ) | 20 | 40 | 40 | 40 | 60 | 60 | |
Flame Sensors | Microamps | • | • | • | • | • | • | |
Diodes in AC to DC Converters | Diode Test | • | • | • | • | • | • | |
Fuses, Light Bulbs, Wire Connections | Continuity | • | • | • | • | • | • | |
Household Batteries | Battery Test | • | • | |||||
Motor Startup or Run Capacitors | Capacitance | • | • | • | • | • | ||
Frequency Verification | Frequency | • | • | • | • | • | ||
Non-Contact Voltage Test | Non-Contact Voltage | • | • | • | • | • | ||
Electrical Load-Time On vs Time Off | Duty Cycle | • | • | • | ||||
Temp of Air Vents, Fuses, Transformers | Temperature Inputs | 1 | 1 | 2 | 2 | |||
F | Automatically Selects Measurement Range | Autoranging | • | • | • | • | • | • |
Manually Select Measurement Range | Manual Ranging | • | • | • | • | • | ||
Voltage on Variable Frequency Drives | Low Pass Filter | • | • | |||||
Detect Stray Voltages | Low Z | • | ||||||
Dimly Lit Areas | Built-in Flashlight | • | • | • | • | • | ||
D | Meter Resolution | LCD Counts | 2,000 | 4,000 | 4,000 | 4,000 | 6,000 | 6,000 |
Dimly Lit Areas | Backlight | • | • | • | • | • | ||
Monitoring Fast Changing Signals | Bar Graph | • | • | • | • | |||
Two Relative Measurements on One Screen | Dual Display | • | • | |||||
E | Data Memory | Data Hold | • | • | • | • | • | • |
Difference Between Two Measurements | Relative Reading | • | • | • | • | • | ||
Max/Min Peak Measurement | Max/Min Hold | • | • | • | • | |||
Specialized Signal Measurements | Peak Hold (Crest) | • | • |
• HVAC
Amprobe AM-520 HVAC Multimeter - Data Sheet 597.9 KB |