True-RMS digital multimeter accurately measures voltage on systems affected by harmonics
The Amprobe AM-530 autoranging digital multimeter is the multimeter of choice for professional electrical contractors. The AM-530 is a True-rms digital multimeter so it accurately measures voltage on systems affected by harmonics. With its full menu of digital multimeter features, you can use it to: measure and verify the presence of voltage before connecting new equipment or performing repairs; run new wiring; check continuity of electrical connections; identify blown fuses; troubleshoot motors or check transformers. The CAT III 600V safety rating provides an extra measure of safety for high voltage multimeter applications. Its built-in flashlight helps you see wire colors in the dark and “third hand probe holder gives you an extra hand when you need it.
The AM-530 comes with test leads, K-Type thermocouple probe, one (1) 9 V (6F22) battery (installed), user's manual, and a velcro strap carrying case.
• True-RMS technology improves accuracy in electrically noisy environments
• Measures AC/DC voltage up to 600 V, AC/DC current, resistance, frequency, capacitance, and temperature
• Non-contact voltage detection enhances safety
• Audible continuity quickly identifies shorts and opens
• Diode test to verify diode polarity
• Data hold freezes the reading on the display for further analysis
• Min/Max recording records Min/Max measurements over time to show voltage fluctuations
• Relative zero mode displays the difference between the actual reading and a stored reference value and may be used with any function or range
• Combines user friendly features such as, auto power-off to conserve battery life, low battery warning, a “third hand test probe holder, built-in test leads storage, a built-in flashlight, and a Velcro strap to hang the meter
• Auto and manual-ranging delivers maximum flexibility
• Backlit LCD display with analog bar graph makes it easy to view results
• CAT III 600 V safety rated
AM-530 | BEST ACCURACY | |
True-RMS | • |
|
AC Voltage | 400 mV, 4.000 V, 40.00 V, | ± (1.0 % RDG + 3 LSD) |
DC Voltage | 400 mV, 4.000 V, 40.00 V, | ± (0.8% RDG + 1 LSD) |
AC Current | 400.0 μA, 4000 μA, | ± (1.2% RDG + 3 LSD) |
DC Current | 400.0 μA, 4000 μA, | ± (1.0% RDG + 2 LSD) |
Frequency | 10 Hz to 10 MHz | ± (0.1% RDG + 4 LSD) |
Resistance | 400.0 Ω, | ± (1.0% RDG + 2 LSD) |
Capacitance | 40.00 nF, 400.0 nF, | ± (3.0% RDG + 5 LSD) |
Temperature | -40°F - 1832°F | ± (1.8% RDG + 6°F) @ > 32°F - 212°F |
Number of Temperature Inputs | Single Thermocouple |
AM-500 | AM-510 | AM-520 | AM-530 | AM-560 | AM-570 | |||
Multimeter Type | Auto-Ranging | Com / Res | HVAC | Electrical | Adv. HVAC | Industrial | ||
F | Safety Rating | Safety | CAT III 600V | CAT III 600V | CAT III 600V | CAT III 600V | CAT IV 600V | CAT IV 600V |
Measure Voltage in Noisy Environments | True-RMS | • | • | |||||
Electrical Panels, AC Outlets | AC Voltage (V) | 600 | 600 | 600 | 600 | 1000 | 1000 | |
DC Systems, Auto/Marine Batteries | DC Voltage (V) | 600 | 600 | 600 | 600 | 1000 | 1000 | |
AC Current - Electrical Panels, Appliances | AC Current (A) | 10 | 10 | 10 | 10 | 10 | 10 | |
DC Current-Electronics, DC Motors | DC Current (A) | 10 | 10 | 10 | 10 | 10 | 10 | |
Specified Resistance and Continuity | Resistance (MΩ) | 20 | 40 | 40 | 40 | 60 | 60 | |
Flame Sensors | Microamps | • | • | • | • | • | • | |
Diodes in AC to DC Converters | Diode Test | • | • | • | • | • | • | |
Fuses, Light Bulbs, Wire Connections | Continuity | • | • | • | • | • | • | |
Household Batteries | Battery Test | • | • | |||||
Motor Startup or Run Capacitors | Capacitance | • | • | • | • | • | ||
Frequency Verification | Frequency | • | • | • | • | • | ||
Non-Contact Voltage Test | Non-Contact Voltage | • | • | • | • | • | ||
Electrical Load-Time On vs Time Off | Duty Cycle | • | • | • | ||||
Temp of Air Vents, Fuses, Transformers | Temperature Inputs | 1 | 1 | 2 | 2 | |||
F | Automatically Selects Measurement Range | Autoranging | • | • | • | • | • | • |
Manually Select Measurement Range | Manual Ranging | • | • | • | • | • | ||
Voltage on Variable Frequency Drives | Low Pass Filter | • | • | |||||
Detect Stray Voltages | Low Z | • | ||||||
Dimly Lit Areas | Built-in Flashlight | • | • | • | • | • | ||
D | Meter Resolution | LCD Counts | 2,000 | 4,000 | 4,000 | 4,000 | 6,000 | 6,000 |
Dimly Lit Areas | Backlight | • | • | • | • | • | ||
Monitoring Fast Changing Signals | Bar Graph | • | • | • | • | |||
Two Relative Measurements on One Screen | Dual Display | • | • | |||||
E | Data Memory | Data Hold | • | • | • | • | • | • |
Difference Between Two Measurements | Relative Reading | • | • | • | • | • | ||
Max/Min Peak Measurement | Max/Min Hold | • | • | • | • | |||
Specialized Signal Measurements | Peak Hold (Crest) | • | • |
• Professional electrical contractors
• Measure and verify the presence of voltage
• Run new wiring
• Check continuity of electrical connections
• Identify blown fuses
• Troubleshoot motors
• Check transformers
Amprobe AM-530 True-RMS Electrical Contractor Multimeter - Data Sheet 598 KB |