The ATEX approved Series AT2605 Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure in hazardous locations. The easily read dial gage is complimented by the two-wire, 4 - 20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gage mechanical design and Series 600 transmitter technology. The two-wire design simplifies any 4 - 20 mA control loop powered by a 10 - 35 VDC supply. Flame-proof ATEX enclosures are available in aluminum and can include a glass window for viewing process pressure on gage face.

Note that for installation, cables must be fitted through 1/2 in NPT cable gland or ATEX conduit (not supplied with instrument.  Make sure after cabling to close tight cover and cable gland, in order to keep IP66 rating (IP65 with option OPV, overpressure relief valve).  Open cover only after de-energizing instrument.  Check local safety rules and warnings on unit and manual for a correct use of the instrument in hazardous area.

• ATEX housing provides all the capabilities and value of the Magnehelic® 605 in a flame & explosion-proof enclosure
• Quick response to pressure changes means no delay in assessing critical situations
• Durable and rugged housing and high-quality components combined provides longservice life and minimized down-time
• High impact strength and high temperature rated for applications where hazardous environments exist
 

GAGE SPECIFICATIONS
Service Air and non-combustible, compatible gases
Wetted Materials Consult factory
Accuracy See 605 ordering page
Pressure Limits See 605 ordering page
Temperature Limits 20F - 120F (-6.67C - 48.9C);
Case: -76F - 140F (-60C - 60C)
Note: Product temperature limits differ from case
Size 4" (101.6 mm) dial face
TRANSMITTER SPECIFICATIONS
Accuracy See 605 ordering page (includes linearity, hysteresis, repeatability)
Compensated Temperature Range 32F - 120F (0C - 48.9C)
Thermal Effect 0.025% FS/F (0.045% FS/C)
Stability 1% FS/year
Power Requirements 10 - 35 VDC (2-wire)
Output Signal 4 - 20 mA
Zero and Span Adjustments Protected potentiometers on 605 face. Can access those by opening case. Allowed only in safe zone
Loop Resistance DC: 0 Ω - 1250 Ω max
Current Consumption DC: 38 mA max
Electrical Connections Screw terminal block
Mounting Orientation Diaphragm in vertical position
Enclosure Rating IP66. IP65 with option OPV, overpressure relief valve
Housing Material Aluminum
Finishing Texture epoxy coat RAL7038
Pressure Connections 1/8 in NPT female brass (SS optional). In presence of acetylene it is necessary to use SS
Electrical Connections Two 1/2 in FNPT. Cable gland not included
Weight 12.6 lb (5.7 kg)
ATEX Approved Products from Comhas with ECN BVI 14ATEX0072
Agency Approvals CE 1370 II2 GD Ex d IIC Gb T6; -60C ≤ Ta ≤ 60C Ex tb IIIC Db T 85C

• Monitor pressures in ducts, rooms, or total building pressures
• Filter monitoring
• Local indication of clean room pressures with process signal sent to control room
• Hazardous area pressure measurement and transmitter