Skip to main content
Press Enter
Burns Engineering

B01 Plate Surface Sensor

Incorporates a bolt-down stainless steel plate with integral RTD or thermocouple

Have questions? We're here to help!
Have questions? We're here to help!

The B01 incorporates a bolt-down stainless steel plate with integral RTD or thermocouple. The B01 can be installed to most flat surfaces to provide temperature monitoring. The low profile sensor with PTFE / FEP jacketed cable allows the measurement location to be fully insulated with plenty of cable to connect to system electronics.

Element ConfigurationRTD: Single and Dual, 100 ohms at 0°C, 0.00385 ohm/ohm/°C nominal alpha
Thermocouple: Single or Dual, Type E, J, K, and T
RTD Temperature Range-50°C to 200°C
Thermocouple Temperature RangeSee Data Sheet
Cable Temperature Limits-50°C to 200°C
Insulation Resistance500 MΩ, 100 VDC at room temperature (Not applicable for grounded thermocouples)
Time ResponseMaximum time to 63.2% of a step change in
temperature of water moving at 3 fps
» 22.2 seconds with heat transfer compound between sensor plate and measurement surface
» 39.8 seconds without heat transfer compound