` CD2-SYS Condumax II Analyzer w/Sample System

Michell Instruments

CD2-SYS Condumax II Analyzer w/Sample System

On-Line Dew-Point Analysis in Natural Gas

Call Today!
800-567-8686 Normally ships in 3-4 Weeks

  Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

 The Condumax II hydrocarbon and water dew-point analyzer provides continuous, automatic measurements of these two critical parameters of natural gas quality. It uses the ‘Dark Spot’ direct chilled-mirror technique to measure hydrocarbon dew point with high accuracy and long-term reliability. Water dew point measurements are provided by Michell’s Ceramic Metal-Oxide Moisture Sensor.

 
The Condumax II is housed in a compact explosion-proof enclosure. Both indoor and outdoor sampling systems are available as standard providing comprehensive sample conditioning natural gas at up to 138 barg. For specific applications and requirements, we offer a custom engineering design service.
 
Condumax II is suitable for use with natural gas containing up to 20 % hydrogen with no further modification required.

• Fully automatic on-line analysis
• Objective, highly repeatable measurements
• 0.5 °C hydrocarbon dew-point accuracy
• Fundamental chilled mirror principle
• Patented detection technique
• Self-cleaning
• No purge or cooling gas required
• Optional water dew-point analysis
• Modbus RTU
• IECEx, ATEX, UKCA, cQPSus and GOST Ex certifications

• Natural gas processing
• Gas quality measurements at custody transfer
• Transmission pipeline monitoring
• Confirmation and control of fuel gas ‘superheat’ to turbine power plant

Item
Description
Availability
Price
Michell standard mounting frame, floor standing w/ sun canopy & 3 sides- 316 box section construction w/ roof & side panels
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
HC dew-point sensor cell assembly (with Storm pressure transmitter)
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Water dew-point sensor assembly (with Storm pressure transmitter)
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Stand alone heated pressure reduction system 240VAC (300 barg/4350 psig inlet, max 507psig/35barg outlet) - ATEX only Stand alone heated pressure reduction system 115VAC (300 barg/4350 psig inlet, max 507psig/35barg outlet) - ATEX only
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Stand alone heated pressure reduction system 240VAC (300 barg/4350 psig inlet, max 507psig/35barg outlet) - ATEX only
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Filter kit for Coalescer and Membrane Separator – each (systems from November 2015)
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Membrane filter elements pack of 5 + 5 Viton O-ring (systems up to October 2015)
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Packing for Main Unit only (crate for air, sea and road)
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure
Packing for Main Unit with Sampling System (crate for air, sea & road)
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Configure