Skip to main content
Press Enter
OMEGA

CL510A PT100 & PT1000 RTD Simulators with multiple or single curves

RTD Simulators

This product is no longer available. Contact us at 800-567-8686 for alternative solutions.

Have questions? We're here to help!
Have questions? We're here to help!

 The CL510A RTD Simulator Series can check and calibrate all your RTD instruments. Take it into the shop, plant or field without worry. It’s easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a decade box and RTD resistance tables, with the CL510A you can calibrate directly in temperature (°C and °F). Choose between a single RTD type model, CL510A-1 (Pt100, 0.00385), or a CL510A-10 for multiple RTD types.

 
The CL510A-10 works with a wide variety of RTD curves including Platinm 100 (alpha = 3850, 3902, 3916, 3926) and 1000 (alpha = 3850, 3750) ?, Copper 10 and 50 ?, Nickel 100 and 120 ?. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL". Connect directly to RTD inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their displays.
• Source One or Multiple RTD Curves 
• High Accuracy 
• Easy-to-Read Backlight Display 
• Calibrate Directly in Temperature (°C or °F) 
• Compatible with All RTD Process Instruments
Specirications(Unless otherwise indicated, all specifications are rated from a nominal 23°C (73°F), 70% RH)
Accuracy±(0.015% of Rdg + 0.05 ?)
Temperature Drift±0.05 ?/°C
Operating Temperature Range-25 to 60°C (-10 to 140°F)
Relative Humidity Range, 10 % ?RH?90%: 0 to 35°C (32 to 95°F), non-condensing
?70%: 35 to 60°C (95 to 140°F), non-condensing
Size126 L x 69 W x 45 mm H (4.96 x 2.73 x 1.79")
Weight0.24 kg (8.4 oz) (including batteries)
Batteries4 "AA" alkaline 1.5V (included)
Battery Life50 hr
Low BatteryLow battery indication with nominal 1 hour of operation left
Protection Against MisconnectionOver-voltage protection to 60 Vdc (rated for 30 sec)
DisplayHigh contrast graphic liquid crystal display, LED backlighting for use in low lit areas
Source
AccuracyFrom 1 to 10.2 mA
External Excitation Current±(0.015% of rdg + 0.05 ?) Below 1 mA of External
Excitation Current±(0.015% of rdg + 0.01 mV/mA excitation current + 0.05 ?)
Resistance Ranges0.00 to 410.00, 410.1 to 4001.0 ?
Allowable Excitation Current Range, Steady or Pulsed/Intermittent<410 ?: 10.2 mA max
410 to 001 ?: 1 mA max Pulsed Excitation Current
CompatibilityDC to 0.01 second pulse width
  • Thumbnail of document Data Sheet - CL510A PT100 & PT1000 RTD Simulators with multiple or single curves
    Download

    Data Sheet - CL510A PT100 & PT1000 RTD Simulators with multiple or single curves

    Download
  • Thumbnail of document Manual - CL510A PT100 & PT1000 RTD Simulators with multiple or single curves
    Download

    Manual - CL510A PT100 & PT1000 RTD Simulators with multiple or single curves

    Download

Request a Calibration Quote

We’re here to make calibration easy. Request a quote today and let our team give you the care, precision, and service you can trust.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more