Skip to main content
Press Enter
Starting at $543.99CAD
Configure
Fluke

ClirVu Infrared Windows

Seals the optic prior to assembly to protect against moisture degradation in very hot & very cold environments

Starting at
$543.99CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

A company's greatest investment is not the equipment that’s behind the panel door; top priority is to offer the ultimate protection for the electricians, engineers and inspectors who risk their lives every day doing their jobs.  The ClirVu® coating - exclusive to Fluke infrared windows - seals the optic prior to assembly to protect against moisture degradation making it perfect for very hot and very cold environments.

Each Fluke infrared window is delivered with an identification plate attached for unique, on-site numbering for rapid location confirmation and faster repairs. 

The CV Series of infrared windows are available in 50 mm (CV200), 75 mm (CV300), and 95 mm (CV400).  For a security key access option, see models CV301 (75 mm), and CV401 (95 mm).

Save time with quick and easy installation with the CV Series (5 minutes or less)
• One technician
• One hole with standard Greenlee® punch
• Panel door does not need to be removed
• Grounds instantly to metal enclosure with patent-pending AutoGround™ process
• Maintains panel arc test ratings up to 63kA when properly installed

Work more efficiently with Fluke ClirVu® CV200 50 mm (2 in), CV300 / CV301 75 mm (3 in), and CV400 / CV401 95 (4 in) Infrared Windows:
• NFPA 70E processes significantly reduced due to less work permit requirements
• Faster and more comfortable inspections because full PPE is often not required
• Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance
• CV200, CV300, and CV400 are Torture Tested™ to the highest arc blast test ratings IEEE C37.20.7: 63 kA Arc tested at KEMA, UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE
• Convenience of both quick turn or security keyed access (CV301 and CV401 only)

General Specifications

 

CV200

CV300 / CV301

CV400 / CV401

Size

50 mm (2 in)

75 mm (3 in)

95 mm (4 in)

Voltage Range

Any

Any

Any

NEMA Environment Type

Type 4/12 (indoor/outdoor)

Type 4/12 (indoor/outdoor)

Type 4/12 (indoor/outdoor)

AutoGround™

Yes

Yes

Yes

ClirVu® Optic

Yes

Yes

Yes

Operating Temperature

  • Thumbnail of document Guide - ClirVu Infrared Windows
    Download

    Guide - ClirVu Infrared Windows

    Download
  • Thumbnail of document Data Sheet - ClirVu Infrared Windows
    Download

    Data Sheet - ClirVu Infrared Windows

    Download
  • Thumbnail of document Brochure - ClirVu Infrared Windows
    Download

    Brochure - ClirVu Infrared Windows

    Download