Includes 4, 8, 12 and 16-channel low-level DC current data loggers, accepts signals from common voltage sources
The CurrentX Series includes 4, 8, 12 and 16-channel low-level DC current data loggers and are available in three ranges: 30 mA, 160 mA, and 3 A.
The CurrentX Series accepts voltage signals from sensors, transducers and many other common voltage sources. Capable of measuring and recording up to 4,192,256 readings, users have the option to enable or disable channels to maximize memory capacity. There’s no interface necessary, the CurrentX Series uses standard USB-A to Micro USB cable.
Using the MadgeTech Software, starting, stopping and downloading from the CurrentX Series data loggers are simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.
• 16-bit Readings Provide High Resolution
• User-defined Engineering Units
• Pushbutton or Programmable Start Time
• External Power or User Replaceable Battery
• Real Time Operation
• Up to 4 Hz Reading Rate
• Title Channels
Memory | 4-channel: 1,048,064 readings per channel 8-channel: 524,032 readings per channel 12-channel: 349,354 readings per channel 16-channel: 262,016 readings per channel (all channels enabled) |
Reading Rate | 4 Hz to 1 reading every 24 hours |
Channels | 4, 8, 12, 16 |
LED Indicators | 1 per channel and 2 status LEDs |
Battery Life | 18 months |
Material | Black anodized aluminum |
Dimensions | 4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) 8-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) 12-channel: 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm) 16-channel: 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm) |
Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing |
Current Range | -2 mA to +30 mA, ±160 mA, ±3 A |
Max Voltage: Inputs & Ground | 3 V (Common mode voltage must be less than 3 volts. All inputs must be within 3 volts of all other inputs.) |
Current Resolution | 30mA: 0.0005 mA 160mA: 0.005 mA 3A: 0.001 A |
Current Calibrate Accuracy | 30mA: ±0.016 mA 160mA: ±0.16 mA 3A: ±0.009 A |
Current Input Impedance | 30mA: 10 Ω 160mA: 1 Ω 3A: 0.1 Ω |
• 4 mA to 20 mA Current Loops
• pH Recording
• Low Level Signal Monitoring
• Photovoltaic Studies
• Battery Studies
• Biological Sensor Monitoring
• Factory Process Control
• Research and Development
• Medical and Pharmaceutical
• Environmental Studies
View All Part Numbers