DP6000-6R4 1/8 DIN Dual Input Process Panel Meter, 6 Digit Display

1/8 DIN Process Panel Meter

Have questions? We're here to help!
Have questions? We're here to help!

 The DP6000 Series meter boasts specifications and functionality that clearly make it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced signal input conditioning functions, function keys, Modbus RTU serial communications, and optional expansion modules are only a few of the features found on the DP6000. Sunlight readable display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/ minimum, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off. The user friendly dual-line display makes the DP6000 easy to set up and program. No jumpers to set for input selection. All setup and programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. The Copy feature is used to copy (or clone) all the settings from one DP6000 to other meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adaptor, only an optional cable assembly.

• Modular USB, RS232, RS485 Serial Communication Options and Relays
• 0 to 20 mA, 4 to 20 mA, 0 to 5V, 1 to 5V, and ±10V Inputs
• NEMA 4X (IP65) Front
• Universal 85 to 265 Vac or 12/24 Vdc Input Power
Programming Methods4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
Noise FilterProgrammable from 2 to 199 (0 will disable filter)
Filter BypassProgrammable from 0.1 to 99.9% of calibrated span
RecalibrationCalibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min DisplayMax (peak)/ min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs
Non-Volatile MemoryAll programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Power Options85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W max, or jumper selectable 12/24 Vdc ±10%, 15 W max
Fuse (External, Required)UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply24 Vdc ±5% @ 200 mA max (standard), (12/24 Vdc powered models rated @ 100 mA max); 5 or 10 Vdc @ 50 mA max, selectable with internal jumper J4
Normal Mode RejectionGreater than 60 dB at 50/60 Hz
Isolation4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
Overvoltage CategoryInstallation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
Operating Temperature Range-40 to 65°C (-40 to 149°F)
Storage Temperature Range-40 to 85°C (-40 to 185°F)
Relative Humidity0 to 90% non-condensing
ConnectionsRemovable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors
Enclosure1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Tightening TorqueScrew terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
Weight269 g (9.5 oz)
DisplayBoth displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
Upper Display15 mm (0.60") high
Lower Display12 mm (0.46") high
Display Intensity8 intensity levels
Display Update Rate5/second (200 ms)
OverrangeDisplay flashes 999999
UnderrangeDisplay flashes -99999
Display AssignmentThe upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input
Front PanelNEMA 4X (IP65)
  • Thumbnail of document Data Sheet - DP6000-6R4 1/8 DIN Dual Input Process Panel Meter, 6 Digit Display
    Download

    Data Sheet - DP6000-6R4 1/8 DIN Dual Input Process Panel Meter, 6 Digit Display

    Download
  • Thumbnail of document Manual - DP6000-6R4 1/8 DIN Dual Input Process Panel Meter, 6 Digit Display
    Download

    Manual - DP6000-6R4 1/8 DIN Dual Input Process Panel Meter, 6 Digit Display