Measures dew points up to 95 °C (203°F) and as low as -35 °C (-31°F), NEMA-4 enclosure
The Edgetech Instruments Model DPS3 is a heated dew point hygrometer that can measure dew points up to 95 °C (203°F) and as low as -35 °C (-31°F). This integrated system includes a microprocessor based electronics, a chilled mirror dew point sensor, a sample flow meter/valve, assorted tubing and fittings all contained in a heated, temperature controlled NEMA-4 enclosure.
• Heated Sensor temperature range: 20 to 99°C (68 to 210°F)
• Dew Point measuring range: -35C to 95 °C (-31 to 203°F)
• AC Power: 100 to 240VAC, 50/60Hz, 250 Watts
• Microprocessor controlled
• 2 line LCD backlit display
• In line filter
• User programmable temperature controller
• Automatic Balance control
• Alarm relay, form C
• Outputs 4-20mA
• RS232 port
• Sample connection: ¼ inch female compression tube fitting
• Sample pressure: 0 to 150 psig max
• Measurement Accuracy: +/-0.2C (+/-0.4F)
• Chilled mirror sensor selection required
Primary Method Chilled Mirror Sensors: | DPS3 available with the HTS2 two stage chilled mirror or HTS3 three stage chilled mirror DPS4 and DPS5 available with HTS2 two stage chilled mirror or HTS3 three stage chilled mirror with standard aluminum body or the HTX3 stainless steel body |
Heated System Temperature Range: | 20 to 99°C (68 to 210°F) |
Dew/Frost Point Measurement Range: | -35 to 95°C (-31 to 203°F) |
Measurement Accuracy: | ±0.2°C (±0.4°F) |
Repeatability: | ±0.05°C (0.9°F) |
User Programmable Temperature Controller: | Standard |
Display Parameters: | Dew/frost point temperature, system set point temperature, system actual temperature |
Two Alarm Relays: | Standard |
Analog Outputs: | Selectable 4 to 20mA, 0 to 5 V dc or 0 to 10 V dc |
Serial RS232 Output: | Standard |
Sample Connection: | ¼ inch compression fitting |
Sample Pressure: | 0 to 200 psig |
Heated Sample Hose: | 3 ft. included |
AC Power: | 100 or 240 V ac, 50/60Hz, 250 Watts, specify voltage |
Mirror Material: | Standard: chrome Optional: stainless steel or platinum |
Sample Flow: | 0.5 to 5.0 SCFH (0.25 to 2.5 l/min) Automatic Balance Control standard Integral adjustable sample flowmeter |
Options: | Pressure transducer kit, live pressure for ppmv output Sample flow detection, sample flow switch with SPST dry contacts Sample flow detection, sample flow switch triggers red lamp alarm Vacuum pump to extract sample flow from process to the sensor Cart mount, specify model analyzer Extended length sample hose, 10 ft. |
• Nuclear Fuel Processing
• Monitor Fluidized Beds (Pharma and Plastics)
• Fuel Cell
• Battery Manufacture
• Polymer / Plastics Processing
• Metals Heat Treating, furnaces, annealing, casting, ingot formation
• Semi-Con Furnace, RTP, silicon ingot
• Food and Beverage heated process
View All Part Numbers