 The DRSL-DC3 isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC3 can be used for signal conversion of standard process voltage or current signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.

 
The DRSL-DC3 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

• Isolation and Conversion of Process Voltage or Current Signals
• Slimline Housing—Only 6 mm (0.24') Wide
• Multiple Signal Ranges (DIP-Switch Selectable)
• High Accuracy, <0.2% of Span

Input
Current Input
Measurement Range 0 to 20.5 mA
Functional Range 0 to 23 mA
Programmable Measurement Ranges 0 to 20 mA and 4 to 20 mA
Input Voltage Drop < 1.5V
Voltage Input
Measurement Range 0 to 10.25V
Functional Range 0 to 11.5V/ 0 to 5.75V
Programmable Measurement Ranges 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V
Input Resistance ≥500 kΩ
Output
Current Output
Signal Range 0 to 20.5 mA (span)
Programmable Signal Ranges 0 to 20 mA and 4 to 20 mA
Load 23 mA/600 Ω max
Load Stability ≤0.01% of span/ 100 Ω
Current Limit ≤28 mA
Voltage Output
Signal Range 0 to 10V
Programmable Signal Ranges 0 to 10, 2 to 10, 0 to 5 and 1 to 5V
Load >10 kΩ min
General
Supply Voltage (via Power Rail or Connectors) 16.8 to 31.2 Vdc
Power Consumption 0.8 W ma
Internal Consumption 0.4 W typical/ 0.65 W max
Isolation Input/Output/Supply
Isolation Voltage (Test) 2.5 kVac
Isolation Voltage (Working) 300 Vac
MTBF >249 years, according to IEC 61709 (SN29500)
Signal/Noise Ratio >60 dB
Response Time (0 to 90%, 100 to 10%) <7 ms
Span Corresponds to the presently selected DIP switch output range
Accuracy <±0.2% of span
Temperature Coefficient <±0.015% of span/°C
EMC Immunity Influence <±0.5% of span
Extended EMC Immunity
NAMUR NE 21, A Criterion, Burst <±1% of span
Environmental
Operating Temperature -25 to 70°C (-13 to 158°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Calibration Temperature 20 to 28°C (68 to 82°F)
Relative Humidity 0 to 95% RH non-condensing
Protection Degree IP20
Installation Area Pollution degree 2 and measurement/overvoltage category II
Mechanical
Dimensions 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5”)
Weight 70 g (0.15 lb) approx
DIN Rail Type DIN EN 60715 - 35 mm
Wire Size 0.13 x 2.5 mm2/AWG 26 to 12 stranded wire
Screw Terminal Torque 0.5 Nm
Item
Description
Availability
Price
Power connector unit, 24 Vdc/2.5 A output to power rail
Normally ships in 3-4 Weeks
Call Today!
800-567-8686
Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length
Normally ships in 2-3 Weeks
Call Today!
800-567-8686
Module stop (screwed onto DIN rail to support and hold mounted devices)
Normally ships in 2-3 Weeks
Call Today!
800-567-8686


Your Recently Viewed Items...