Skip to main content
Press Enter
Buy now! $19,970.48CAD
Fluke

DSX2-5-IE-K1 Cable Analyzer Kit

Industrial Ethernet DSX CableAnalyzer™ Kit

Buy now!
$19,970.48CAD
Have questions? We're here to help!
Have questions? We're here to help!

 Studies show that half of Industrial Ethernet problems are caused by cabling. The DSX CableAnalyzer validates cable performance to TIA 1005-A and ISO 11801:3 standards, allowing industrial companies and machine builders to ensure compliance, start up faster, and reduce production down time.

 
The DSX CableAnalyzer works on cables running EtherNet/IP™, Profnet™, ModBus TCP™, EtherCAT, plus other protocols. It offers touchscreen project management, TIA Level IIIe accuracy, and advanced troubleshooting, all with integrated Wi-Fi and 8-hour battery life.
 
The kit includes the Versiv mainframe and remote units, a reference module, adapters, commonly used accessories, and a statement of calibration. 
• Certifies copper cable for TIA category 5 through 6A
• Shows Pass/Fail in 10 seconds, with full measurement details
• Supports RJ45, M12D, and M12X connectors
• Documents results with LinkWare™ PC
Cable Types
Shielded and unshielded pair LAN cablingTIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard link interface adapters
Permanent link adaptersPlug type: shielded RJ45
Optional Plug type: Tera
Channel AdaptersJack type: shielded RJ45
Optional Jack type: Tera, GG45
Test standards
TIACategory 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IECClass C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum FrequencyDSX-5000: 1000 MHz
General Specifications
Speed of AutotestDSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL)
Input protectionProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display5.7 in LCD display with a projected capacitance touchscreen
CaseHigh impact plastic with shock absorbing overmold
WeightMain Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
DimensionsMain Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Overload recovery timeLess than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Accuracy± (1 Ω + 1 %)
Resolution0.1 Ω
Range0 Ω to 540 Ω
DC loop resistance test
Accuracy± 10 ns
Resolution1 ns
Range0 ns to 100 ns
Delay skew
Accuracy± (2 ns + 2 %)
Resolution1 ns
Range750 ns
With Remote
Accuracy± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
Resolution1 ns
Range4000 ns
Without Remote
Propagation delay
Main unit and remoteLithium ion battery pack, 7.2 V
Typical battery life8 hours
Change timeTester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supportedEnglish, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
CalibrationService center calibration period is 1 year
Integrated Wi-FiMeets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental Specifications
Operating Temperature32°F to 113°F (0°C to 45°C)
Storage Temperature-14°F to +140°F (-10°C to +60°C)
Operating relative humidity0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
VibrationRandom, 2 g, 5 Hz-500 Hz
Shock1 m drop test with and without module and adapter
SafetyCSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating Altitude13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMCEN 61326-1
Performance specifications
DSX-5000
Category 6A/Class EA test modes (or lower link categories)Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modesExceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of twisted pair cabling
Without Remote
Range800 m (2600 ft)
Resolution0.1 m or 1 ft
Accuracy± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
With Remote
Range150 m (490 ft)
Resolution0.1 m or 1 ft
Accuracy± (0.3 m + 2 %)
  • Thumbnail of document Data Sheet - DSX2-5-IE-K1 Cable Analyzer Kit
    Download

    Data Sheet - DSX2-5-IE-K1 Cable Analyzer Kit

    Download
  • Thumbnail of document Manual - DSX2-5-IE-K1 Cable Analyzer Kit
    Download

    Manual - DSX2-5-IE-K1 Cable Analyzer Kit

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more