` FLEX Environmental Monitor - Alpha Controls & Instrumentation Inc.

Setra Systems

FLEX Environmental Monitor

Monitor and control up to 3 spaces, monitoring up to 6 parameters for each room

Starting At
$3,556.00 CAD
Normally ships in 1-2 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

Setra FLEX™ provides a flexible room environmental control and monitoring solution in a simple-to-use package. An attractive flush mount face plate is complemented by an intuitive graphical display to meet any architectural requirement.
 
More Than a Room Pressure Monitor - The unit supports 3 rooms, monitoring up to 6 parameters for each room. These optional additional parameters can include humidity, temperature, occupancy, particle count, door status, air velocity, and many more environmental factors. An optional differential pressure sensor can be either factory-installed in the unit or ordered separately and installed above the ceiling. Integration with building automation systems is made easy through either BACnet/IP or BACnet MS/TP network protocols.
 
Modular Design - A modular hardware design enables FLEX to fit in various wall thickness found around the globe. For applications which require the monitor to fit in wall depths less than 50mm, FLEX can be ordered with an external pressure sensor. When mounting in a three gang electrical box, FLEX can be ordered with an integrated on-board sensor. Sufficient on-board I/O provides connectivity for most common equipment and sensor applications. A high accuracy of 0.25% differential pressure transducer is used in all pressure sensing options. A projected capacitive touch screen provides swipe functionality and allowed for use with medical gloves. The face plate is attached to the unit body, enabling both tamper resistant operation and easy opening for pressure calibration.
 
Setra FLEX-RM and FLEX-RC - FLEX software is designed to suit any application, with the ability to support up to 3 rooms. FLEX-RM (Room Monitor) provides monitoring only, for those applications where no control from the touch screen is needed. FLEX-RC (Room Control) offers monitoring, plus PI loop or network control of VAV boxes, venturi valves, or hydronic reheat valves. Software is pre-installed, with configuration and network integration done using simple setup screens. There is no programming required. When completed, configuration settings on one unit can be cloned to other devices using a standard USB thumb drive, thereby shortening commissioning time. Units can also be configured remotely over a BACnet network.
 
FLEX's monitor is both a controller and a monitor, with audible and visual alarming on all room parameters. FLEX's monitor enables users to save energy by choosing from two PI control loops and two monitoring sets for any of four room modes, such as occupied and unoccupied.
 
Optional adapter boxes are available for installations where cutting into the wall is not possible.

• Monitor and Control Up to 3 Spaces
• 6 Parameters per Room, Total 18
• 7" Touch Screen, Works with Medical Gloves
• Integrates with BMS Systems
• BACnet/IP and BACnet MS/TP
• USB Cloning Feature Saves Time
• High Accuracy Pressure Transducer

Dimensions 9.25” W x 6.3” H x 0.65”D
(215.0mm x 160.0mm x 16.51mm)
Mounting Triple-gang, double deep electrical box. RACO 697,
Appleton M3-350, or equivalent
Case Fire-retardant plastic UL94 V-0
Weight 2 lbs
Display 7” Projected Capacitive (PCAP) multitouch. 800 x 480 pixels. Usable with medical gloves.
Display Brightness 1-7
USB Port Micro-USB port for configuration cloning between units and software upgrades.
Audible Alarm Dual piezo with 3 volume levels (0-75 dB max.)
Protocols BACnet/IP using IPv4, Ethernet CAT5 cables with RJ45
BACnet MS/TP up to 76.8 kbps, 3-conductor, twisted,
shielded 16-24 AWG cable
Power 24 VAC (18-32 VAC operational), 50-60 HZ
Power Draw 13 W max, 10 W typical
Wire 2 or 3-conductor (depending on application)
stranded unshielded twisted pair, 16-24 AWG
Connections Removable Terminal Blocks
Operating Temp. °F (°C) 32 to 120 (0 to 50)
Storage Temp. °F (°C) -40 to 185 (-40 to 85)
Operating Humidity 5 to 95% RH (non-condensing)
Ingress Protection (IP) Rating IP54
Chemical Resistance Exposed surfaces are chemically resistant to vaporized hydrogen peroxide (VHP),
formaldehyde, chlorine dioxide (clidox), perchloric acid, sodium hypochlorite 3-6%
(bleach), quaternary ammonium 7% in 1:128 tap water (ammonia).
Accuracy RSS ±0.25%
Non-Linearity (BFSL) ±0.24%
Hysteresis ±0.05%
Non-Repeatability ±0.05%
Span Setting Tol. ±0.5% Rdg
Zero/Span Shift % FS ± 0.03% PSI (±0.05% FS)
Overpressure ±1 PSI (15” WC for ≤0.10” WC FS)
Pressure Media Air or non-conductive, non-explosive gases
Pressure Fittings 3/16” barbed fittings
Altitude 6562 ft. (2000 m) max.
Position Housing to be 90° in reference to level surface, ±5°

• Hospitals - ASHRAE Standard 170
• Pharmacies - USP 797 & USP 800
• Bio-safety & Vivarium Laboratories
• Pharmaceutical Manufacturing
• Custom for OEM, Energy, Industrial
• Server Rooms & Data Centers