Determine the actual solar irradiance (Watts/m²) and shading at the site to develop a baseline
If you’re surveying, installing, executing maintenance or checking performance of solar panels or a photovoltaic system, the Fluke IRR1-SOL Irradiance Meter gives you the 4 critical measurements needed all in one easy-to-use tool. Make instantaneous measurements to determine the watt per square meter solar irradiation, required by IEC 62446-1 standard. Measure temperature by either placing the meter directly on the panel or by connecting the external probe. Find cardinal direction with the compass, and verify inclination of a roof or panel with the tilt function.
• Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles
Irradiance | |
Measuring Range | 0 to 1400 W/m² |
Resolution | 1 W/m² |
Measuring Accuracy | ± (5 % + 5 Digit) |
Temperature Measurement | |
Measuring range (°C) | -22 °F to 212 °F (-30 °C to 100 °C) |
Resolution | 0.2 °F (0.1 °C) / 1 °F @>100 °F |
Measuring Accuracy | ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C), ±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C) |
Note: Temperature measurement response time: ~30 sec. | |
Inclination Angle | |
Measuring Range | -90° to +90° |
Resolution | 0.1° |
Measuring Accuracy | ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90° |
Compass | |
Measuring Range | 0° to 360° |
Resolution | 1° |
Measuring Accuracy | ±7° |
Note: a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---". b) Result is referred to magnetic north. |
|
Temperature | |
Operating Temperature IRR1-SOL | -20 °C to 50 °C (humidity <80%), noncondensing |
Operating Temperature 80PR-IRR | -30 °C to +100 °C |
Storage Temperature | -30 °C to 60 °C (humidity <80%) |
Altitude | 0 m to max. 2000 m |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable Electromagnetic Environment |
CISPR 11: Group 1, Class A | |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | |
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) |
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Protection | |
IP Protection | IP40 |
Power Supply & Battery Life | |
Batteries | 4 AA Alkaline Batteries |
Battery Life (typical) | 50 hours (≤9000 readings) |
Auto Power Off | 30 minutes |
Dimensions | |
L x W x H | 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm) |
Weight | 0.5 lb (231 g) |
Fluke FLK-IRR1-SOL Solar Irradiance Meter - Data sheet 1.2 MB |