The FLSC-45 is a dc powered frequency-to-analog output signal conditioner with a 4 to 20 mA or 1 to 5 Vdc field selectable output. The high performance electronics will accept a low level magnetic pickup signal from a paddlewheel or turbine meter directly without amplification and convert it to an industry-standard analog output. Two models are available, the standard FLSC45, with a plastic enclosure for wall mounting, and the FLSC45B, which features a rugged die-cast aluminum housing with a NEMA 4 (IP65) rating.
| Accuracy | ±0.15% FS |
| Repeatability | ±0.025% |
| Input | Sine wave 20 mV pp min |
| Output | 4 to 20 mA or 1 to 5 Vdc; field selectable |
| Response Time | 2 sec fixed |
| Frequency Input Range to Achieve FS Output | 65 to 7600 Hz |
| power | 10 to 32 Vdc for 4 to 20 mA and 15 to 32 for 1 to 5 Vdc output |
| Operating Temperature | -20 to 60°C (-4 to 140°F) |
| Storage Temperature | -25 to 70°C (-12 to 158°F) Enclosure: |
| Enclosure | FLSC45: polypropylene |
| FLSC45: polypropylene | |
| Dimensions | FLSC45: 61 H x 104 W x 25.4 mm D (2.4" x 4.1" x 1")FLSC45: 61 H x 104 W x 25.4 mm D (2.4" x 4.1" x 1") |
| FLSC45B: 65 H x 116 W x 32 mm D (2.6 x 4.6 x 1.3") | |
| Weight | FLSC45: 96 g (3.3 oz) |
| FLSC45B: 300 g (10.6 oz) |
| OMEGA FLSC-45B High Performance Flow Signal Conditioners - Data sheet 177.9 KB |
| OMEGA FLSC-45B High Performance Flow Signal Conditioners - Manual 621.1 KB |