GPR-1900 Oxygen Analyzer

Panel mounted oxygen analyzer with a remote sensor, suitable for trace oxygen measurements as low as 0-1 ppm

This product is no longer available. Contact us at 800-567-8686 for alternative solutions.

Have questions? We're here to help!
Have questions? We're here to help!

The AII GPR-1900 Oxygen Analyzer is a panel mounted oxygen analyser with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-1 ppm. The remote sensor block allows a very easy oxygen sensor replacement for simple and fast maintenance and low cost of ownership. All versions can be locked manually to a single range or auto-range. The user is always aware of the oxygen measurement range used via the range ID output.

• Measurement ranges from 0-10ppm up to 0-100% O2
• Barometric pressure and temperature compensation
• Accuracy of better than 2% of range
• Two user configurable alarms
• Range ID output
• 12-28 V DC or mains powered options
• XLT sensor options for CO2 backgrounds

Measurement Range0-10, 0-100, 0-1000 ppm, 0-1%, 0-25%
Accuracy< 2% of selected range at constant conditions
Response TimeT90 < 10 seconds
Recovery Time60 seconds in air to < 10 ppm in < 1 hr on N2 purge
Sensitivity (LDL)0.05 ppm
Linearity< 0.5% of scale
Sensor ModelGPR-11-60-4
XLT-11-24-4 for gases containing > 0.5% CO2
Sensor Life 25ºC (77°F) and 1 atm24 months in < 1000 ppm O2
6 months in air
Calibration Interval30 days
Inlet Pressure0.34 2 barg (5-30 psig) with atmospheric vent
Flow Rate0.5 1.0 l/m (1-2 SCFH)
Gas Connections1/8" compression tube fittings
Wetted PartsStainless steel
DisplayGraphical LCD 12.7 x 7cm (5 x 2.75”); resolution 0.001 ppm
EnclosurePainted aluminum 6" x 4" x 4" panel mount
CompensationBarometric pressure and temperature
Signal Output4-20 mA or 1-5V
Range ID4-20 mA non-isolated or 1-5V
Option: reassign relay contacts (eliminates standard alarms)
AlarmsTwo user configurable alarms: magnetic coil relays rated 3A at 100 V AC
Operating TemperatureGPR sensors: 5°C to 45°C (41°F to 113°F)
XLT sensors: -10°C to 45°C (14°F to 113°F)
Power100-240 V AC or 12-28 V DC
  • Thumbnail of document Data Sheet - GPR-1900 Oxygen Analyzer
    Download

    Data Sheet - GPR-1900 Oxygen Analyzer

    Download
  • Thumbnail of document Manual - GPR-1900 Oxygen Analyzer
    Download

    Manual - GPR-1900 Oxygen Analyzer

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more