` HC2A-ICXXX Standard Industrial Humidity Probe

Rotronic

HC2A-ICXXX Standard Industrial Humidity Probe

Suitable for heavy industrial applications with through Wall installations

Starting At
$1,915.00 CAD
Normally ships in 3-4 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

Suitable for Heavy Industrial Applications with Through Wall Installations

The ROTRONIC industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point.

Applications
Production environments, high temperatures, industrial manufacturing, drying processes, climatic chambers
 

• Range of application: -100…200 °C / 0…100 %rh
• Digital interface (UART) and scalable analog outputs, 0…1 V
• Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
• Adjusted at 23 °C and 10, 35, 80 %rh

Probe type Industrial probe
Operating range -100…200 °C / 0…100 %rh
Accuracy at 23 ±5 °C ±0.8 %rh / ±0.1 K
Accuracy w. adjustment profile "standard" at 23 °C / 10, 35, 80 %rh ± 0.8 %rh / ± 0.1 K
Measuring range -100...200 °C (short-term peak load) / 0...100 %rh
Power supply /power consumption 3.3 V ± 0.1V / ~4.5 mA
Long-term stability <1 %rh / year
Humidity sensor Hygromer IN-1
Temperature sensor PT100 1/3 DIN Class B
Probe protection Filter carrier, brass nickel plated
Filter cartridge Depending on the application, order separately
Response time T 63 <15 sec.
Allowed wind speed 3 m/s
Psychrometric calculations Dew or frost point
Reproducibility airchip <0.02 %rh / 0.01 K
Exploitation software ROTRONIC HW4
Probe adjustment by software 1 Point & multipoint %rh & °C
Firmware update With internet and HW4 software
User information From Software HW4 (devicemanager)
Data processing via HW4 With interface cables
Device protection by password Yes
Type of output signals 2 x 0…1 VDC
Analogue outputs scaleable by the user Yes
Analogue output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Digital output signal (standard) UART
Service interface UART
Reverse voltage protection Mechanically in the connector
Sensor frame for %RH and °C sensor Yes
Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable
Probe material PEEK
FDA / GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible
Dimensions Ø15 x 100 mm / Ø15 x 250 mm / Ø15 x 400 mm / Ø15 x 550 mm / Ø15 x 700 mm
Weight 230 g / 260 g / 290 g / 330 g / 350 g /