` HC2A-IMXXX Steel Industrial Humidity Probe

Rotronic

HC2A-IMXXX Steel Industrial Humidity Probe

Stainless steel probe for through wall installation, suitable for high temperatures, demanding industrial environments and areas where hygiene plays an important role

Starting At
$2,115.00 CAD
Normally ships in 3-4 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

Stainless Steel Probe for Through Wall Installation

The metal industrial probe is especially suitable for high temperatures, demanding industrial environments and areas where hygiene plays an important role. The probe measures humidity and temperature and calculates the dew/frost point.

Applications
Food and pharmaceutical production, drying processes, industrial manufacturing
 

• Range of application: -100…200 °C, (screw-in probe; -50…200 °C) / 0…100 %rh
• Digital interface (UART) and scalable analog outputs, 0…1 V
• Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
• Adjusted at 23 °C and 10, 35, 80 %rh

Probe type Industrial metal probe
Operating range -100…200 °C / 0…100 %rh
Accuracy at 23 ±5 °C ±0.8 %rh / ±0.1 K
Accuracy w. adjustment profile "standard" At 23 °C / 10, 35, 80 %rh ± 0.8 %rh / ± 0.1 K
Power supply / Power consumption 3.3 V ± 0.1V / ~4.5 mA
Long-term stability <1 %rh / year
Humidity sensor Hygromer IN-1
Temperature sensor PT100 1/3 DIN Class B
Probe protection Filter carrier, brass nickel plated
Filter cartridge Depending on the application, order separately
Response time t 63 <15 sec.
Allowed wind speed 3 m/s
Psychrometric calculations Dew or frost point
Reproducibility Airchip <0.02 %rh / 0.01 K
Exploitation software ROTRONIC HW4
Probe adjustment by software 1 Point & multipoint %rh & °C
Firmware update With internet and HW4 software
User information From Software HW4 (devicemanager)
Data processing via HW4 With interface cables
Device protection by password Yes
Type of output signals 2 x 0…1 VDC
Analog outputs scaleable by user Yes
Analog output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Digital ooutput signal (standard) UART
Service interface UART
Reverse voltage protection Mechanically in the connector
Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable
Probe material Stainless steel 1.4305 (V2A)
Probe cable material FEP, black
Enclosure material Stainless steel 1.4305 (V2A)
FDA / GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible
Dimensions Ø15 x 130 mm / Ø15 x 280 mm / Ø15 x 430 mm / Ø15 x 580 mm
Weight 260 g / 400 g / 540 g / 680 g



Your Recently Viewed Items...