Rotronic

HC2A-S3/HC2-S3H Meteorolgy Probes

The most versatile probe from Rotronic and forms the basis of their product portfolio, measures RH, temperature and calculates dew/frost point

Starting At
$540.00 CAD
Normally ships in 2-3 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The HC2A-S3 / HC2A-S3H is the most versatile probe from ROTRONIC and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point. The HC2-S3H fulfills the highest demands for measuring accuracy.

• Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C ±5 K (±0.5 %RH - HC2-S3H)
• Range of application: -50…100 °C / 0…100 %rh
• Digital interface (UART) and scalable analog outputs, 0…1 V
• Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
• Adjusted at 23 °C and 10, 35, 80 %rh

Probe Type Meteorological probe
Operating Range -50100 C / 0100 %rh
Accuracy w. Adjustment Profile "Standard" 0.8 %RH / 0.1 K, at 10...30 C
Adjustment at 23 C and 10, 35, 80 %RH
Accuracy w. Adjustment Profile "High Precision" 0.5 %RH / 0.1 K, at 10...30 C
at 23 C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %RH
Power Supply / Power Consumption 3.3...5 VDC, Calibration @ 3.3 VDC / ~4.5 mA
Long-Term Stability <1 %rh / year
Humidity Sensor Hygromer HT-1
Temperature Sensor PT100 1/3 DIN Class B
Probe Protection Polycarbonate plastic cage, white
Filter Cartridge Polyethylene dust filter, white, 40 um
Filter Type Polyethylene, 40 μm
Response Time T 63 <15 sec.
Allowed Wind Speed 20 m/s, with filter
Psychrometric Calculations Dew or frost point
Reproducibility Airchip <0.02 %rh / 0.01 K
Exploitation Software ROTRONIC HW4
Probe Adjustment by Software 1 Point & multipoint %rh & C
Firmware Update With internet and HW4 software
User Information From Software HW4 (devicemanager)
Data Processing Via HW4 With interface cables
Device Protection by Password Yes
Type of Output Signals 2 x 01 VDC
Analogue Outputs Scaleable by the User Yes
Analog Output Signal (Standard) 01 V = 0100 %rh; 01 V = -4060 C
Digital Output Signal (Standard) UART
Communication Interfaces UART
Service Interface UART
Reverse Voltage Protection Mechanically in the connector
Max. Cable Length Up to 5 m with passive cable. Up to 100 m with active cable
Enclosure Material Polycarbonate
FDA/GAMP Compatibility FDA 21 CFR Part 11 and GAMP compatible
Dimensions 15 x 108 mm
Weight 17 g
Item
Description
Availability
Price
MKRS-HC2 Adaptor
HC2A-S3/S3H adaptor for RS application
Normally ships in 2-3 Weeks
$1,185.00 CAD