Skip to main content
Press Enter
Michell Instruments

HG10 Humidy Calibrator System

Automatic calibration system w/ reference hygrometer, wide range of RH generation, 1 to 95% RH, -50 to +50°C dp

Have questions? We're here to help!
Have questions? We're here to help!

The Michell HG10 Humidity Calibration System is a highly flexible computer-controlled automatic calibration system for humidity sensors. The HG10 is capable of repeatable generation of temperature and relative humidity set points over the range 1 to 95% RH 
(-50 to +50°Cdp) at temperatures of +20 to +50°C with excellent stability. The supplied chilled mirror reference instrument provides traceability directly to national standards, and makes the system suitable for use in high-level calibration laboratories. 

The supplied PC software allows the creation of automatic calibration programs, for evaluating the performance of humidity sensors over a range of operating conditions. The measured values from the chilled mirror reference are used in a closed control loop to enable repeatable set point generation, time and time again.

• Automatic calibration system with reference hygrometer
• Wide range of humidity generation 1 to 95% RH, -50 to +50°Cdp
• High accuracy ±0.1°C fundamental reference
• User-configurable temperature and humidity profiling allows calibration cycles to be run without constant supervision
• Very fast changes between generated relative humidity points
 

Remote PRT
Temperature Measurement4 wire Pt100, 1/10 DIN class B
Accuracy±0.1°C (±0.18°F)
Cable Length2m (6.6ft) (250m (820ft) max)
Optional Remote Pressure Sensor
Measurement Range0 to 25 bara (0 to 377 psia)
Accuracy0.25% Full Scale
Measurement Unitspsia, bara, KPa or MPag
Pressure Transducer Thread1/8” NPT
Monitor
ResolutionUser-selectable to 0.001 dependant on parameter
General
Enclosure19” Rack System, H= 2.1m
Power Supply100 to 115 V or 220 to 240 V 50/60Hz
Pressure Swing Dryer
Gas Output Flow: 7 Nl/min
Pressure: 0.68 barg
Moisture Content: <1ppmV (<-75°Cdp)
Required Gas SupplyFlow: 10 Nl/min
Pressure: 5 to 7 barg
Moisture Content: Oil and liquid water free
TypeTwin column desiccant, pressure swing
Desiccant4 Ångström Molecular sieve bead (4-8 mesh)
TimerMotorized cam
Operating Temperature+5 to +35°C
Generator
Generation RangeHumidity: 1 to 95% RH (-50 to +50°Cdp)
Temperature: Dependant on temperature chamber
Generated Gas OutputAir 2 Nl/min @ 0.5 barg via heat traced line
Dual Stage MFC MixingDual mass flow controllers
Power Consumption550 V A maximum
Dual Stage MFC MixingDual mass flow controllers
Operating Temperature+5 to +40°C; 10 to 90% RH
Enclosure19" Rack System, H= 2.1m
Control SystemClosed loop feedback
S8000
Dew-Point Sensor Performance
Performance
Accuracy±0.1°C (±0.18°F)
Reproducibility±0.05°C (±0.09°F)
Measurement TechnologyChilled Mirror
Sensor
Dew-point Range 2-Stage–40°Cdp@ sensor temp of +20°C +90°Cdp @ sensor temp of +90°C
Dew-point Range High Temp PEEK–40°Cdp @ sensor temp of +20°C +120°Cdp @ sensor temp of +120°C
Dew-point Range Climatic Head–10°Cdp @ sensor temp of +20°C +120°Cdp @ sensor temp of +120°C
Temperature Range 2-Stage–40 to +90°C
Temperature Range High Temp PEEK–40 to +120°C
Temperature Range Climatic Head–40 to +120°C
%RH Range 2-Stage<0.5 to 100%
%RH Range High Temp PEEK<0.5 to 100%
%RH Range Climatic Head10 to 100%
Min Measured Dew Point @ 20°C 2-Stage & High Temp PEEK–40°C
Min Measured Dew Point @ 20°C Climatic Head–10°C
Mirror Material OptionsGold plated copper (standard), gold stud, Platinum stud
Sensor Body Material OptionsAcetal (standard), high temperature PEEK, Anodized aluminum
Response Speed1°C/sec (1.8°F/sec) plus settling time
Operating Pressure20 barg (290 psig) standard pressure High version: 250 barg (3625 psig) max
Measurement Units °C and °F for dew point and temperature %RH, g/m3, g/kg, ppm , %Vol, ppm (SF ), for calculated V W 6 humidities
Outputs Analog Digital:
3 channels, user selectable 4–20 mA, 0–20 mA or 0–1 V Modbus RTU over USB and optionally Modbus RTU over RS232 or RS485, or Modbus TCP over ethernet.

Alarm:
Two volt free changeover contacts, one process alarm, one fault alarm; 1 A @ 30 V DC
HMI5.7” LCD with touchscreen
Data Logging SD Card (512Mb supplied) and USB interface SD Card (FAT-16) – 2Gb max. that allows 24 million logs or 560 days, logging at 2 second intervals
Environmental Conditions–20 to +50°C (–4 to +122°F)
Power Supply85 to 264 V AC, 47/63 Hz
Power Consumption100 V A
Mechanical Specifications
Dimensions (Instrument)190 x 255 x 215mm (7.5 x 10.0 x 8.4”) h x w x d
Dimensions (Sensor)ø45 x 128mm with M36 x 1.5-6g mounting thread
Weight4.2kg (9.26lbs)
Cable Lengths3, 5 or 10m (9.8, 16.4 or 32.8ft)
General
Storage Temperature–40 to +60°C (–40 to +140°F)
Detection SystemSingle optics detection system with auto adjustment
Calibration 4-point traceable in-house calibration as standard; UKAS accredited calibrations optional – please consult Michell Instruments
  • Thumbnail of document Data Sheet - HG10 Humidy Calibrator System
    Download

    Data Sheet - HG10 Humidy Calibrator System

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.