Skip to main content
Press Enter
Starting at $4,399.35CAD
Configure
Dwyer

IEF Insertion Electromagnetic flow transmitter

An adjustable insertion flowmeter featuring electromagnetic technology that accurately & reliably measures fluid velocity

Starting at
$4,399.35CAD
Have questions? We're here to help!
Have questions? We're here to help!
Configure

The Series IEF Insertion Electromagnetic Flow Transmitter is an adjustable insertion flowmeter featuring electromagnetic technology that accurately and reliably measures fluid velocity in addition to providing several continuous signal outputs. This series is specifically designed to offer superior performance paired with simple installation and use. One unit is adjustable to fit pipe sizes from 4 to 36" (101.6 to 914.4 mm), and offers several output options including selectable BACnet MS/TP or Modbus® RTU communications protocol over 2-wire RS-485 in addition to the standard analog, frequency and alarm outputs.

• Meet application requirements with field configurable setup displays (-LCD integral option or remote accessory A-IEF-DSP), which accommodate a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
• Maintain system efficiency with high performance accuracy that is maintained through changes in temperature, density or viscosity
• Quick and easy ordering and set up with Setup Wizard and installation tool that are simple to use and allow for precise installation
• Save time with accessory setup kit A-IEF-KIT that ensures exact installation application depth with included thickness gage and measuring tape
• Reduced costs, long product life, and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
• Minimize installation costs with isolation valve accessory options to allow for installation in operational systems via hot-tap kit or easy removal without system downtime
• Required documents included with NIST traceable pass/fail verification certificate included standard for Carbon Steel Schedule 40 pipes sized 4" (102 mm), 6" (150 mm), 8" (200 mm)
Wetted Materials:Body shaft/fitting: 316SS; Electrodes: 316SS; Electrode cap: Polymer/Polystyrene; O-ring: Silicon.
Range:0 to 20 ft/s (0 to 6 m/s).
Service:Compatible clean or dirty non coating, conductive liquids.
Glycol:0 to 100% display selectable.
Diameter Length Requirements:>10 upstream, >5 downstream.
Applicable Pipe Size:4 to 36" (100 to 900 mm), model dependent. See model chart on catalog page.
Applicable Pipe Material:Most popular plastic and metal pipes; i.e. Carbon steel, SS, copper, UPVC/PVDF, galvanized steel, mild steel, and brass*.
ADDITIONAL SPECIFICATIONS
Device Load:1/8 unit load.
Supported Baud Rates:9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).
Type:BACnet MS/TP or Modbus® RTU communication protocol (default disabled, display selectable).
COMMUNICATIONS (-COM OPTION)
Agency Approvals:BTL, CE, NSF/ANSI 61 and 372.
Enclosure Ratings:NEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option).
Enclosure Material:Powder coated die cast aluminum.
Conductivity:>20 microsiemens.
Display:2" ( 5.08 cm) x 2" (5.08 cm) graphic LCD with backlight.
Electrical Connection:Removable terminal blocks, model selectable 1/2" female NPT conduit connection, PG 16 gland or PG 16 gland with (2) 10' (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200' (61 m) optional.
Power Requirements:12 to 42.4 VDC, .25 A @ 24 VDC; 12 to 36 VAC.
Outputs:(1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable);
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable);
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable);
(1) Reverse flow output indication.
Pressure Drop:< 0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe.
Pressure Limits:400 psi (27.6 bar) @ 100º F (37.8°C).
Process Connection:1" NPT or BSPT with accessory full port ball valve options.
Temperature Limits:Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C).
Accuracy:High accuracy units: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s);
Standard accuracy units: ±1% FS.
• Boiler feed water
• Chilled water
• Open and closed loop condenser water
• Irrigation system
• Municipal water distribution
• Process and coolant flow
• Ground water remediation
• Chemical processing
• Pump protection
• Wastewater
• Mining

  • Thumbnail of document Data Sheet - IEF Insertion Electromagnetic flow transmitter
    Download

    Data Sheet - IEF Insertion Electromagnetic flow transmitter

    Download
  • Thumbnail of document Brochure - IEF Insertion Electromagnetic flow transmitter
    Download

    Brochure - IEF Insertion Electromagnetic flow transmitter

    Download

Request a Service Quote

Get a customized quote for calibration, validation, repair, or training services designed to keep your instruments accurate and compliant.
Learn more

Browse By Brands

Uncover the brands that set the standard for quality and dependability in every industry we serve.
Learn more